Tao Bian
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Tao Bian has a total of 8 co-authors. Here are the top co-authors by number of shared publications:
- Yunhe Li
School of Electronic and Electrical Engineering, Zhaoqing University, Zhaoqing 526060, China
2 shared publications Haitao Wu
Shenzhen Chenzhuo Technology Company (China)
1 shared publication- Haitao Wu
Shenzhen CZTEK Co., Ltd., Shenzhen 518055, China
1 shared publication Mei Yang
Zhaoqing University (China)
1 shared publication- Mei Yang
School of Electronic and Electrical Engineering, Zhaoqing University, Zhaoqing 526060, China
1 shared publication - Wenhui Xia
School of Electronic and Electrical Engineering, Zhaoqing University, Zhaoqing 526060, China
1 shared publication
Latest Publications
- Open Access
- 31 August 2026
- Published by MDPI AG in Information
- Vol. 17 (9) , 844
Low-Resolution Magnetic Tile Defect Image Recognition Based on Task-Aware AMCANet
Low-resolution magnetic tile defect recognition suffers from the loss of texture, edge and fine-grained defect information, which weakens discriminative features and reduces recognition accuracy in industrial inspection. To improve defect recognition under low-resolution imaging conditions, this paper proposes a task-aware low-resolution magnetic tile defect image recognition method based on AMCANet. AMCANet is used as the basic super-resolution reconstruction network, and a fixed high-resolution classifier is introduced during training to construct feature consistency loss and classification task loss. Thus, the reconstructed images are constrained to approach high-resolution images at the pixel level while preserving defect-discriminative features. Experiments on the Magnetic Tile Surface Defect Dataset show that the proposed TA-AMCANet achieves an Accuracy of 0.9065 and a Macro-F1 of 0.8204 under the fixed-classifier evaluation setting, improving on the original AMCANet by 0.3238 and 0.3726, respectively. Further ablation, loss-weight sensitivity, AMCA Block configuration, cross-classifier, degradation robustness, external-dataset generalization, Grad-CAM visualization, and computational complexity experiments verify the effectiveness of the proposed task-aware strategy. The results further indicate that higher pixel-level reconstruction metrics do not necessarily correspond to better downstream defect recognition performance, while TA-AMCANet improves recognition adaptability without introducing additional parameters or inference overhead. The method provides an effective solution for low-resolution industrial defect recognition.
- 31 August 2026
- Published by MDPI AG in Information
- Vol. 17 (9) , 844
Open AccessLow-Resolution Magnetic Tile Defect Image Recognition Based on Task-Aware AMCANet
Low-resolution magnetic tile defect recognition suffers from the loss of texture, edge and fine-grained defect information, which weakens discriminative features and reduces recognition accuracy in industrial inspection. To improve defect recognition under low-resolution imaging conditions, this paper proposes a task-aware low-resolution magnetic tile defect image recognition method based on AMCANet. AMCANet is used as the basic super-resolution reconstruction network, and a fixed high-resolution classifier is introduced during training to construct feature consistency loss and classification task loss. Thus, the reconstructed images are constrained to approach high-resolution images at the pixel level while preserving defect-discriminative features. Experiments on the Magnetic Tile Surface Defect Dataset show that the proposed TA-AMCANet achieves an Accuracy of 0.9065 and a Macro-F1 of 0.8204 under the fixed-classifier evaluation setting, improving on the original AMCANet by 0.3238 and 0.3726, respectively. Further ablation, loss-weight sensitivity, AMCA Block configuration, cross-classifier, degradation robustness, external-dataset generalization, Grad-CAM visualization, and computational complexity experiments verify the effectiveness of the proposed task-aware strategy. The results further indicate that higher pixel-level reconstruction metrics do not necessarily correspond to better downstream defect recognition performance, while TA-AMCANet improves recognition adaptability without introducing additional parameters or inference overhead. The method provides an effective solution for low-resolution industrial defect recognition.
- Open Access
- 19 October 2024
- Published by MDPI AG in Information
- Vol. 15 (10) , 655
MRI Super-Resolution Analysis via MRISR: Deep Learning for Low-Field Imaging
This paper presents a novel MRI super-resolution analysis model, MRISR. Through the utilization of generative adversarial networks for the estimation of degradation kernels and the injection of noise, we have constructed a comprehensive dataset of high-quality paired high- and low-resolution MRI images. The MRISR model seamlessly integrates VMamba and Transformer technologies, demonstrating superior performance across various no-reference image quality assessment metrics compared with existing methodologies. It effectively reconstructs high-resolution MRI images while meticulously preserving intricate texture details, achieving a fourfold enhancement in resolution. This research endeavor represents a significant advancement in the field of MRI super-resolution analysis, contributing a cost-effective solution for rapid MRI technology that holds immense promise for widespread adoption in clinical diagnostic applications.
- 19 October 2024
- Published by MDPI AG in Information
- Vol. 15 (10) , 655
Open AccessMRI Super-Resolution Analysis via MRISR: Deep Learning for Low-Field Imaging
This paper presents a novel MRI super-resolution analysis model, MRISR. Through the utilization of generative adversarial networks for the estimation of degradation kernels and the injection of noise, we have constructed a comprehensive dataset of high-quality paired high- and low-resolution MRI images. The MRISR model seamlessly integrates VMamba and Transformer technologies, demonstrating superior performance across various no-reference image quality assessment metrics compared with existing methodologies. It effectively reconstructs high-resolution MRI images while meticulously preserving intricate texture details, achieving a fourfold enhancement in resolution. This research endeavor represents a significant advancement in the field of MRI super-resolution analysis, contributing a cost-effective solution for rapid MRI technology that holds immense promise for widespread adoption in clinical diagnostic applications.
- 27 September 2024
- Published by SPIE-Intl Soc Optical Eng
- Vol. 13281, 36-301
Enhancing low-dose CT images by 4x using CACTSR: a deep learning model
Computed Tomography is a crucial diagnostic tool in medicine but exposes patients to harmful radiation. Low-dose CT reduces radiation but leads to noisy images. Super-resolution technology can reconstruct high-resolution images from low-resolution scans, enhancing image quality while reducing radiation. This study proposes a novel deep learning model, CACTSR, which integrates VMamba and Transformer technologies with Mixed Attention Blocks and Cross Attention Blocks to enhance feature utilization and facilitate cross-window information interaction. Experimental results on the QING LUNG dataset demonstrate that CACTSR surpasses existing methods in terms of image quality metrics, generating images with crisp edges and abundant details. This innovative approach effectively mitigates block artifacts and enhances image quality, providing a powerful solution for reducing radiation doses in clinical CT imaging while maintaining diagnostic accuracy.
- 27 September 2024
- Published by SPIE-Intl Soc Optical Eng
- Vol. 13281, 36-301
Enhancing low-dose CT images by 4x using CACTSR: a deep learning model
Computed Tomography is a crucial diagnostic tool in medicine but exposes patients to harmful radiation. Low-dose CT reduces radiation but leads to noisy images. Super-resolution technology can reconstruct high-resolution images from low-resolution scans, enhancing image quality while reducing radiation. This study proposes a novel deep learning model, CACTSR, which integrates VMamba and Transformer technologies with Mixed Attention Blocks and Cross Attention Blocks to enhance feature utilization and facilitate cross-window information interaction. Experimental results on the QING LUNG dataset demonstrate that CACTSR surpasses existing methods in terms of image quality metrics, generating images with crisp edges and abundant details. This innovative approach effectively mitigates block artifacts and enhances image quality, providing a powerful solution for reducing radiation doses in clinical CT imaging while maintaining diagnostic accuracy.