TZTao Zhang

Tao Zhang

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Tao Zhang has a total of 20 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Anti-cancer Potential of Farrerol Against Esophageal Carcinoma via Inhibiting STAT3-EGFR Signaling Pathway

    by Yangyang Bai, Tao Zhang, Shaik Althaf Hussain, Turki Mayudh Alrubie, Feiyan Long

  • Open Access

    Case report: Rudimentary uterine horn with ovarian endometriosis manifested as pelvic ectopic kidney

    by Si-Fan Yin, Jia-Gui Chai, Run-Lin Feng, Zhi-Yuan Yin, Shen-Zhao Zhao, Tao Zhang, Chang-Xing Ke

    Background: Unicornuate uterus is a congenital uterine malformation. Unicornuate uterus with rudimentary horn, ovarian endometriosis, and congenital renal agenesis are rare combinations that can be easily misdiagnosed due to the lack of typical clinical manifestations.Case summary: A 19-year-old woman with pelvic pain was admitted to the hospital after a month. Physical examination was unremarkable. B-ultrasound and CT scan both indicated pelvic ectopic kidney. In addition, renal scintigraphy revealed normal perfusion and function of the right kidney, but the perfusion and function of the left kidney were not visible. A left pelvic ectopic kidney was diagnosed by preoperative images. A laparoscopic left pelvic ectopic nephrectomy was performed after adequate surgical preparation. However, the postoperative pathological diagnosis revealed a rudimentary uterine horn with ovarian endometriosis and congenital renal agenesis. Fortunately, she got recovered and was discharged from the hospital after 5 days following the operation. Moreover, she received regular follow-ups at the gynecology clinic. To date, no right adnexal or uterine abnormalities have been detected on ultrasound during the follow-up visits.Conclusion: Rudimentary uterine horn with ovarian endometriosis and congenital renal agenesis are rare and are easily Misdiagnosed due to the lack of typical clinical manifestations. A gynecological examination is recommended for patients who may have this disease.


  • Open Access

    Spinal epidural hematoma after spinal manipulation therapy: Report of three cases and a literature review

    by Hua Liu, Tao Zhang, Tao Qu, Cheng-Wei Yang, Song-Kai Li

    Spinal manipulation therapy (SMT) has been widely used worldwide to treat musculoskeletal diseases, but it can cause serious adverse events. Spinal epidural hematoma (SEH) caused by SMT is a rare emergency that can cause neurological dysfunction. We herein report three cases of SEH after SMT. The first case was a 30-year-old woman who experienced neck pain and numbness in both upper limbs immediately after SMT. Her symptoms persisted after 3 d of conservative treatment, and she was admitted to our hospital. Magnetic resonance imaging (MRI) demonstrated an SEH, extending from C6 to C7. The second case was a 55-year-old man with sudden back pain 1 d after SMT, numbness in both lower limbs, an inability to stand or walk, and difficulty urinating. MRI revealed an SEH, extending from T1 to T3. The third case was a 28-year-old man who suddenly developed symptoms of numbness in both lower limbs 4 h after SMT. He was unable to stand or walk and experienced mild back pain. MRI revealed an SEH, extending from T1 to T2. All three patients underwent surgery after failed conservative treatment. The three cases recovered to ASIA grade E on day 5, 1 wk, and day 10 after surgery, respectively. All patients returned to normal after 3 mo of follow-up. SEH caused by SMT is very rare, and the condition of each patient should be evaluated in full detail before operation. SEH should be diagnosed immediately and actively treated by surgery.


  • Open Access

    Rotator cuff repair with a novel mesh suture: An ex vivo assessment of mechanical properties

    by Tao Zhang, Taku Hatta, Andrew R. Thoreson, ChengChang Lu, Scott P. Steinmann, Steven L. Moran, Chunfeng Zhao

    Surgical repair is a common treatment for rotator cuff tear; however, the retear rate is high. A high degree of suture repair strength is important to ensure rotator cuff integrity for healing. The purpose of this study was to compare the mechanical performance of rotator cuffs repaired with a mesh suture versus traditional polydioxanone suture II and FiberWire sutures in a canine in vitro model. Seventy‐two canine shoulders were harvested. An infraspinatus tendon tear was created in each shoulder. Two suture techniques—simple interrupted sutures and two‐row suture bridge—were used to reconnect the infraspinatus tendon to the greater tuberosity, using three different suture types: Mesh suture, polydioxanone suture II, or FiberWire. Shoulders were loaded to failure under displacement control at a rate of 20 mm/min. Failure load was compared between suture types and techniques. Ultimate failure load was significantly higher in the specimens repaired with mesh suture than with polydioxanone suture II or FiberWire, regardless of suture technique. There was no significant difference in stiffness among the six groups, with the exception that FiberWire repairs were stiffer than polydioxanone suture II repairs with the simple interrupted technique. All specimens failed by suture pull‐out from the tendon. Based on our biomechanical findings, rotator cuff repair with the mesh suture might provide superior initial strength against failure compared with the traditional polydioxanone suture II or FiberWire sutures. Use of the mesh suture may provide increased initial fixation strength and decrease gap formation, which could result in improved healing and lower re‐tear rates following rotator cuff repair. © 2017 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 36:987–992, 2018.