Danuta Owczarek
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Danuta Owczarek has a total of 24 co-authors. Here are the top co-authors by number of shared publications:
- Ksenia Ostrowska
Cracow University of Technology
7 shared publications - Krzysztof Tomczyk
Faculty of Electrical and Computer Engineering, Cracow University of Technology, Warszawska 24, 31-155 Krakow, Poland
5 shared publications - Jerzy Sładek
Mechanical Faculty, Cracow University of Technology, Jana Pawła II 37 Avenue, 31-864 Krakow, Poland
4 shared publications - Adam Gąska
Faculty of Mechanical Engineering, Cracow University of Technology, 31-864 Cracow, Poland
3 shared publications - Wiktor Harmatys
Cracow University of Technology
3 shared publications - Ireneusz Dominik
Faculty of Mechanical Engineering and Robotics, AGH University of Krakow, al. Mickiewicza 30, 30-059 Kraków, Poland
2 shared publications
Latest Publications
- Open Access
- 1 October 2026
- Published by WNGB Scientific Publishing House Sp. z o.o. in Advances in Science and Technology Research Journal
- Vol. 20 (10) , 21-31
Automation of the matting process for improved accuracy in optical coordinate measurements
Optical coordinate measurements provide numerous benefits, such as high speed and non-contact operation; however, they are highly sensitive to the surface properties of the object being measured. Surfaces that are highly reflective or transparent, in particular, present significant challenges for...
- 1 October 2026
- Published by WNGB Scientific Publishing House Sp. z o.o. in Advances in Science and Technology Research Journal
- Vol. 20 (10) , 21-31
Open AccessAutomation of the matting process for improved accuracy in optical coordinate measurements
Optical coordinate measurements provide numerous benefits, such as high speed and non-contact operation; however, they are highly sensitive to the surface properties of the object being measured. Surfaces that are highly reflective or transparent, in particular, present significant challenges for...
- 13 January 2026
- Published by Elsevier in Measurement
- Vol. 266
Improving dimensional accuracy in stereolithography using a novel multi-factor correction matrix based on coordinate measurements
- 13 January 2026
- Published by Elsevier in Measurement
- Vol. 266
Improving dimensional accuracy in stereolithography using a novel multi-factor correction matrix based on coordinate measurements
- Open Access
Review of Accuracy Assessment Methods for Current Transformers: Errors, Uncertainties, and Dynamic Performance
Accurate electric current measurement is fundamental to the safe and efficient operation of modern power systems. Current transformers (CTs), which serve as a critical interface between high-voltage power networks and measuring or protection devices, are susceptible to various errors and uncertainties that can significantly impact the reliability of measurement results. This article provides a critical and comprehensive review of the current literature concerning the types and causes of errors in CTs, with particular emphasis on current ratio error and phase displacement. Special attention is given to the role of international standards in defining accuracy classes and permissible error limits. Methods for evaluating measurement uncertainty are also discussed, in accordance with the guidelines outlined in the Guide to the Expression of Uncertainty in Measurement (GUM), highlighting their decisive impact on the credibility of measurement results. Modern approaches—such as the application of artificial intelligence in estimating measurement errors—are also considered. This review serves as a comprehensive resource for engineers, metrologists, and researchers seeking to enhance the accuracy of CTs, particularly in measurement and protection applications.
Open AccessReview of Accuracy Assessment Methods for Current Transformers: Errors, Uncertainties, and Dynamic Performance
Accurate electric current measurement is fundamental to the safe and efficient operation of modern power systems. Current transformers (CTs), which serve as a critical interface between high-voltage power networks and measuring or protection devices, are susceptible to various errors and uncertainties that can significantly impact the reliability of measurement results. This article provides a critical and comprehensive review of the current literature concerning the types and causes of errors in CTs, with particular emphasis on current ratio error and phase displacement. Special attention is given to the role of international standards in defining accuracy classes and permissible error limits. Methods for evaluating measurement uncertainty are also discussed, in accordance with the guidelines outlined in the Guide to the Expression of Uncertainty in Measurement (GUM), highlighting their decisive impact on the credibility of measurement results. Modern approaches—such as the application of artificial intelligence in estimating measurement errors—are also considered. This review serves as a comprehensive resource for engineers, metrologists, and researchers seeking to enhance the accuracy of CTs, particularly in measurement and protection applications.
- Open Access
The Impact of an Object’s Surface Material and Preparatory Actions on the Accuracy of Optical Coordinate Measurement
Optical coordinate measurement is a universal technique that aligns with the rapid development of industrial technologies and new materials. Nevertheless, can this technique be consistently effective when applied to the precise measurement of all types of materials? As shown in this article, an analysis of optical measurement systems reveals that some materials cause difficulties during the scanning process. This article details the matting process, resulting, as demonstrated, in lower measurement uncertainty values compared to the pre-matting state, and identifies materials for which applying a matting spray significantly improves the measurement quality. The authors propose a classification of materials into easy-to-scan and hard-to-scan groups, along with specific procedures to improve measurements, especially for the latter. Tests were conducted in an accredited Laboratory of Coordinate Metrology using an articulated arm with a laser probe. Measured objects included spheres made of ceramic, tungsten carbide (including a matte finish), aluminum oxide, titanium nitride-coated steel, and photopolymer resin, with reference diameters established by a high-precision Leitz PMM 12106 coordinate measuring machine. Diameters were determined from point clouds obtained via optical measurements using the best-fit method, both before and after matting. Color measurements using a spectrocolorimeter supplemented this study to assess the effect of matting on surface color. The results revealed correlations between the material type and measurement accuracy.
Open AccessThe Impact of an Object’s Surface Material and Preparatory Actions on the Accuracy of Optical Coordinate Measurement
Optical coordinate measurement is a universal technique that aligns with the rapid development of industrial technologies and new materials. Nevertheless, can this technique be consistently effective when applied to the precise measurement of all types of materials? As shown in this article, an analysis of optical measurement systems reveals that some materials cause difficulties during the scanning process. This article details the matting process, resulting, as demonstrated, in lower measurement uncertainty values compared to the pre-matting state, and identifies materials for which applying a matting spray significantly improves the measurement quality. The authors propose a classification of materials into easy-to-scan and hard-to-scan groups, along with specific procedures to improve measurements, especially for the latter. Tests were conducted in an accredited Laboratory of Coordinate Metrology using an articulated arm with a laser probe. Measured objects included spheres made of ceramic, tungsten carbide (including a matte finish), aluminum oxide, titanium nitride-coated steel, and photopolymer resin, with reference diameters established by a high-precision Leitz PMM 12106 coordinate measuring machine. Diameters were determined from point clouds obtained via optical measurements using the best-fit method, both before and after matting. Color measurements using a spectrocolorimeter supplemented this study to assess the effect of matting on surface color. The results revealed correlations between the material type and measurement accuracy.
- Open Access
A New Methodology for Selecting CT Scanning Parameters Depending on the Density of Materials
The CT (computed tomography) scanner has been used for many years now not only for medical measurements but also in many industries, for example, in defectoscopy for measuring sheet thickness and checking the joining of materials, as well as for measuring the geometry of individual components. This type of scanner is a good complement to coordinate contact and non-contact measurements for intra-structural measurements and inaccessible places. The variety of materials, however, makes it very difficult to select individual CT parameters. In this paper, a curve for selecting the maximum and minimum voltage of the lamp depending on the density of a given material is determined and an interpolation polynomial (1d with a third-degree polynomial) is used, by defining third-degree glued functions (cubic spline) to determine intermediate voltage values to a given material density, so as to determine full data ranges. This approach can facilitate the work of selecting scanning parameters for non-destructive testing, as this is a difficult process and sometimes consumes half of the measurement time. The practical experiments were carried out at the Accredited Coordinate Metrology Laboratory to develop a multi-criteria matrix for selecting CT measurement parameters for measurement accuracy. This approach reduced the time by an average of half an hour and effectively optimized the selection of scanning parameters.
Open AccessA New Methodology for Selecting CT Scanning Parameters Depending on the Density of Materials
The CT (computed tomography) scanner has been used for many years now not only for medical measurements but also in many industries, for example, in defectoscopy for measuring sheet thickness and checking the joining of materials, as well as for measuring the geometry of individual components. This type of scanner is a good complement to coordinate contact and non-contact measurements for intra-structural measurements and inaccessible places. The variety of materials, however, makes it very difficult to select individual CT parameters. In this paper, a curve for selecting the maximum and minimum voltage of the lamp depending on the density of a given material is determined and an interpolation polynomial (1d with a third-degree polynomial) is used, by defining third-degree glued functions (cubic spline) to determine intermediate voltage values to a given material density, so as to determine full data ranges. This approach can facilitate the work of selecting scanning parameters for non-destructive testing, as this is a difficult process and sometimes consumes half of the measurement time. The practical experiments were carried out at the Accredited Coordinate Metrology Laboratory to develop a multi-criteria matrix for selecting CT measurement parameters for measurement accuracy. This approach reduced the time by an average of half an hour and effectively optimized the selection of scanning parameters.
- Open Access
- 29 October 2024
- Published by MDPI AG in Preprints.org
Method for Determining the Influence of Material Density on Set Parameters in X-Ray Computed Tomography Measurement
The CT (computed tomography) scanner has been used for many years now not only for medical measurements, but also in many industries, mostly for tasks such as defectoscopy, measuring sheet thickness, checking the joining of materials, but also for measuring the geometry of individual components. It is a good complement to coordinate contact and non-contact measurements for intra-structural measurements and inaccessible places. The variety of materials, however, makes it very difficult to select individual CT parameters. In this paper, a curve for selecting the maximum and minimum voltage of the lamp depending on the density of a given material has been determined and an interpolation polynomial (1d third-degree polynomial) has been used, by defining 3rd-degree glued functions (cubic spline) to determine intermediate voltage values to a given material density, so as to determine full data ranges. This approach will facilitate the work of selecting scanning parameters for nondestructive testing, as this is a difficult process and sometimes consumes half of the measurement time. Work is underway at the Accredited Coordinate Metrology Laboratory to develop a multi-criteria matrix for selecting CT measurement parameters for measurement accuracy.
- 29 October 2024
- Published by MDPI AG in Preprints.org
Open AccessMethod for Determining the Influence of Material Density on Set Parameters in X-Ray Computed Tomography Measurement
The CT (computed tomography) scanner has been used for many years now not only for medical measurements, but also in many industries, mostly for tasks such as defectoscopy, measuring sheet thickness, checking the joining of materials, but also for measuring the geometry of individual components. It is a good complement to coordinate contact and non-contact measurements for intra-structural measurements and inaccessible places. The variety of materials, however, makes it very difficult to select individual CT parameters. In this paper, a curve for selecting the maximum and minimum voltage of the lamp depending on the density of a given material has been determined and an interpolation polynomial (1d third-degree polynomial) has been used, by defining 3rd-degree glued functions (cubic spline) to determine intermediate voltage values to a given material density, so as to determine full data ranges. This approach will facilitate the work of selecting scanning parameters for nondestructive testing, as this is a difficult process and sometimes consumes half of the measurement time. Work is underway at the Accredited Coordinate Metrology Laboratory to develop a multi-criteria matrix for selecting CT measurement parameters for measurement accuracy.
- Open Access
- 22 October 2024
- Published by MDPI AG in Preprints.org
Point Cloud as Imaging Effect in Coordinate Optical Measurement—A New Method for Evaluating Measurement Accuracy (OPTI‐U)
The article presents extremely current issues concerning imaging and measurements carried out using coordinate optical systems in which the result of scanning spatial objects is a point cloud. What is important, the entire accuracy assessment of the conducted fast, effective coordinate measurement nowadays takes place in the computational area, beyond direct sensory percep-tion, and depends increasingly on its power and the computational algorithms used. Further-more, we are getting closer and closer to recognising virtual standards in coordinate metrology as a direction that allows for an increase in measurement accuracy. Especially in recent years, the importance of the problem has been confirmed by the activities of the most significant scientific and research centres. They focus on improving the accuracy of the data obtained in the form of point clouds, using more precise scanning methods for this purpose, and developing filtering algorithms to remove noise, including methods using artificial intelligence. Based on many years of research, the authors identified a problem regarding the difficulty in developing data obtained from optical systems, such as laser triangulation head systems, systems operating on the principle of structural light, photogrammetric systems, as well as computer tomographs, and the impact of these systems on the assessment of measurement accuracy. Therefore, the optical measurement process was analysed in terms of the quality of the acquired point clouds. The authors presented the division of factors, which, in coordinate optical meas-urements, generate errors in data acquisition and development. The authors also indicated which of these factors generate the most significant errors and, above all, emphasised the impact of the software used, the measurement operator, and the methods of cloud filtration applied by the operator. Therefore, the accuracy assessment of the optical measurement has been noted as a critical problem, and so far, it has not been solved effectively. In the article, as a solution to this problem, the authors proposed the OPTI-U method of estimating uncertainty for optical meas-urements. The method, what is very important, was developed and verified under the conditions of an accredited calibration laboratory. The summary also gives directions for further work on developing and disseminating the developed method, particularly introducing virtual standards.
- 22 October 2024
- Published by MDPI AG in Preprints.org
Open AccessPoint Cloud as Imaging Effect in Coordinate Optical Measurement—A New Method for Evaluating Measurement Accuracy (OPTI‐U)
The article presents extremely current issues concerning imaging and measurements carried out using coordinate optical systems in which the result of scanning spatial objects is a point cloud. What is important, the entire accuracy assessment of the conducted fast, effective coordinate measurement nowadays takes place in the computational area, beyond direct sensory percep-tion, and depends increasingly on its power and the computational algorithms used. Further-more, we are getting closer and closer to recognising virtual standards in coordinate metrology as a direction that allows for an increase in measurement accuracy. Especially in recent years, the importance of the problem has been confirmed by the activities of the most significant scientific and research centres. They focus on improving the accuracy of the data obtained in the form of point clouds, using more precise scanning methods for this purpose, and developing filtering algorithms to remove noise, including methods using artificial intelligence. Based on many years of research, the authors identified a problem regarding the difficulty in developing data obtained from optical systems, such as laser triangulation head systems, systems operating on the principle of structural light, photogrammetric systems, as well as computer tomographs, and the impact of these systems on the assessment of measurement accuracy. Therefore, the optical measurement process was analysed in terms of the quality of the acquired point clouds. The authors presented the division of factors, which, in coordinate optical meas-urements, generate errors in data acquisition and development. The authors also indicated which of these factors generate the most significant errors and, above all, emphasised the impact of the software used, the measurement operator, and the methods of cloud filtration applied by the operator. Therefore, the accuracy assessment of the optical measurement has been noted as a critical problem, and so far, it has not been solved effectively. In the article, as a solution to this problem, the authors proposed the OPTI-U method of estimating uncertainty for optical meas-urements. The method, what is very important, was developed and verified under the conditions of an accredited calibration laboratory. The summary also gives directions for further work on developing and disseminating the developed method, particularly introducing virtual standards.