SJShuang Jin

Shuang Jin

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Shuang Jin has a total of 12 co-authors. Here are the top co-authors by number of shared publications:

  • Gen Li

    2020 X-Lab, Shanghai Institute of Microsystem and Information Technology, Chinese Academy of Sciences, Shanghai 200050, China

    1 shared publication
  • Haoyang Su

    2020 X-Lab, Shanghai Institute of Microsystem and Information Technology, Chinese Academy of Sciences, Shanghai 200050, China

    1 shared publication
  • Jiazhi Li

    2020 X-Lab, Shanghai Institute of Microsystem and Information Technology, Chinese Academy of Sciences, Shanghai 200050, China

    1 shared publication
  • Liuyang Sun

    State Key Laboratory of Transducer Technology, Shanghai Institute of Microsystem and Information Technology, Chinese Academy of Sciences, Shanghai 200050, China

    1 shared publication
  • Lunming Qin

    College of Electronic and Information Engineering, Shanghai University of Electric Power, Shanghai, China

    1 shared publication
  • Tiger H. Tao

    State Key Laboratory of Transducer Technology, Shanghai Institute of Microsystem and Information Technology, Chinese Academy of Sciences, Shanghai 200050, China

    1 shared publication

Latest Publications

  • Open Access

    A Wireless Bi-Directional Brain–Computer Interface Supporting Both Bluetooth and Wi-Fi Transmission

    by Wei Ji, Haoyang Su, Shuang Jin, Ye Tian, Gen Li, Yingkang Yang, Jiazhi Li, Zhitao Zhou, Xiaoling Wei, Tiger H. Tao, et al.

    Wireless neural signal transmission is essential for both neuroscience research and neural disorder therapies. However, conventional wireless systems are often constrained by low sampling rates, limited channel counts, and their support of only a single transmission mode. Here, we developed a wireless bi-directional brain–computer interface system featuring dual transmission modes. This system supports both low-power Bluetooth transmission and high-sampling-rate Wi-Fi transmission, providing flexibility for various application scenarios. The Bluetooth mode, with a maximum sampling rate of 14.4 kS/s, is well suited for detecting low-frequency signals, as demonstrated by both in vitro recordings of signals from 10 to 50 Hz and in vivo recordings of 16-channel local field potentials in mice. More importantly, the Wi-Fi mode, offering a maximum sampling rate of 56.8 kS/s, is optimized for recording high-frequency signals. This capability was validated through in vitro recordings of signals from 500 to 2000 Hz and in vivo recordings of single-neuron spike firings with amplitudes reaching hundreds of microvolts and high signal-to-noise ratios. Additionally, the system incorporates a wireless stimulation function capable of delivering current pulses up to 2.55 mA, with adjustable pulse width and polarity. Overall, this dual-mode system provides an efficient and flexible solution for both neural recording and stimulation applications.