Yangkai Guo
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Yangkai Guo has a total of 5 co-authors. Here are the top co-authors by number of shared publications:
- Yanfeng Li
North China Institute of Aerospace Engineering 2 , Langfang, Hebei 065000
2 shared publications - Jiaqi Liu
School of Instrument and Electronics, North University of China, Taiyuan, China
1 shared publication - Qianfang Xie
School of Instrument and Electronics, North University of China, Taiyuan 030051, China
1 shared publication - Wenzhuo Wang
Key Laboratory of Instrumentation Science and Dynamic Measurement, Ministry of Education, North University of China 1 , Taiyuan, Shanxi 030051
1 shared publication - Zhijie Zhang
North University of China
1 shared publication
Latest Publications
- 1 October 2025
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 96 (10)
Thermocouple dynamic characteristics compensation based on improved equilibrium optimizer algorithm
In transient high-temperature measurement, thermocouples often exhibit poor accuracy due to insufficient dynamic response. To address this issue, this study proposes a thermocouple dynamic characteristic compensation method based on an Improved Equilibrium Optimizer algorithm. The EO algorithm is enhanced by introducing good point set-based population initialization and dynamic weighting factors, aiming to improve the dynamic performance of thermocouples. Experiments were conducted using a high-temperature furnace platform, and the compensation results demonstrated that the thermocouple time constant was reduced from 21.31 to 1.72 s, with a 92% improvement in dynamic response speed. In addition, the cutoff frequency was increased from 0.982 to 12.87 Hz, expanding the operating bandwidth by 13.1 times. After compensation, thermocouples with short exposed junctions also achieved superior dynamic characteristics. This work enables accurate temperature measurement under extreme environments using short-exposed thermocouples.
- 1 October 2025
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 96 (10)
Thermocouple dynamic characteristics compensation based on improved equilibrium optimizer algorithm
In transient high-temperature measurement, thermocouples often exhibit poor accuracy due to insufficient dynamic response. To address this issue, this study proposes a thermocouple dynamic characteristic compensation method based on an Improved Equilibrium Optimizer algorithm. The EO algorithm is enhanced by introducing good point set-based population initialization and dynamic weighting factors, aiming to improve the dynamic performance of thermocouples. Experiments were conducted using a high-temperature furnace platform, and the compensation results demonstrated that the thermocouple time constant was reduced from 21.31 to 1.72 s, with a 92% improvement in dynamic response speed. In addition, the cutoff frequency was increased from 0.982 to 12.87 Hz, expanding the operating bandwidth by 13.1 times. After compensation, thermocouples with short exposed junctions also achieved superior dynamic characteristics. This work enables accurate temperature measurement under extreme environments using short-exposed thermocouples.
- 1 October 2024
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 95 (10)
C-type two-thermocouple sensor design between 1000 and 1700 °C
At the present stage of transient ultra-high-temperature energy release of boron-containing warm-pressure explosives, single thermocouples are often used for multi-point measurements in the process of their temperature field changes, and the results of their temperature field reconstruction are not satisfactory due to the limited consistency of the thermocouples. Aiming at the above-mentioned problems, a C-type two-thermocouple suitable for transient temperature measurement in high-temperature environments is designed; the system characterization of the two-thermocouple is carried out by using the blind system identification method of the inter-relationships; the identification process is evaluated by a new cost function; and the optimal solution on the new cost function is realized by using the gradient descent method. The temperature reconstruction of the two-thermocouple output excited by the simulated heat source is carried out by using the auto-regressive with extra inputs model, and the feasibility of the reconstruction results is verified. In the experimental part, a thermocouple dynamic characteristic calibration system based on a high-temperature furnace is constructed and experimental validation is carried out in the high-temperature furnace to compare the effects of different exposure lengths and different wire diameters on the output of the two-thermocouple, and as a result, the outputs are corrected and analyzed. The results show that two-thermocouple methods with different combinations of wire diameters are better for temperature measurement, with a reconstructed root mean squared error of 0.0162 and a goodness of fit of 89.13%.
- 1 October 2024
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 95 (10)
C-type two-thermocouple sensor design between 1000 and 1700 °C
At the present stage of transient ultra-high-temperature energy release of boron-containing warm-pressure explosives, single thermocouples are often used for multi-point measurements in the process of their temperature field changes, and the results of their temperature field reconstruction are not satisfactory due to the limited consistency of the thermocouples. Aiming at the above-mentioned problems, a C-type two-thermocouple suitable for transient temperature measurement in high-temperature environments is designed; the system characterization of the two-thermocouple is carried out by using the blind system identification method of the inter-relationships; the identification process is evaluated by a new cost function; and the optimal solution on the new cost function is realized by using the gradient descent method. The temperature reconstruction of the two-thermocouple output excited by the simulated heat source is carried out by using the auto-regressive with extra inputs model, and the feasibility of the reconstruction results is verified. In the experimental part, a thermocouple dynamic characteristic calibration system based on a high-temperature furnace is constructed and experimental validation is carried out in the high-temperature furnace to compare the effects of different exposure lengths and different wire diameters on the output of the two-thermocouple, and as a result, the outputs are corrected and analyzed. The results show that two-thermocouple methods with different combinations of wire diameters are better for temperature measurement, with a reconstructed root mean squared error of 0.0162 and a goodness of fit of 89.13%.