Nattachote Rugthaicharoencheep
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Nattachote Rugthaicharoencheep has a total of 10 co-authors. Here are the top co-authors by number of shared publications:
- Supawud Nedphokaew
Department of Electrical Engineering, Faculty of Engineering, Rajamangala University of Technology Phra Nakhon, Bangkok 10800, Thailand
7 shared publications - Natchapol Ruangsap
Department of Electrical Engineering, Faculty of Engineering, Rajamangala University of Technology Phra Nakhon, Bangkok 10800, Thailand
5 shared publications - Narate Charlangsut
Department of Electrical Engineering, Faculty of Engineering, Rajamangala University of Technology, Phra Nakhon, Bangkok 10800, Thailand
2 shared publications - Nitikorn Kesphrom
Department of Electrical Engineering, Faculty of Engineering, Rajamangala University of Technology Phra Nakhon, Bangkok 10800, Thailand
2 shared publications Aroon Charlangsut
Rajamangala University of Technology Phra Nakhon
1 shared publicationManat Boonthienthong
Rajamangala University of Technology Phra Nakhon
1 shared publication
Latest Publications
- Open Access
- 6 April 2026
- Published by MDPI AG in Applied Sciences
- Vol. 16 (7) , 3568
Application of Ozone Gas Technology for Extending Shelf Life and Controlling Pests in the Orchid and Grape Industries
This paper presents the application of ozone for pest control in large-scale systems, with the potential for industrial implementation. The designed ozone generation system is capable of producing an ozone concentration of 550 ppm within 30 min in a controlled chamber. Ozone technology was applied for the control of insect pests in the orchid export industry, both for current use and future applications. A high-concentration ozone generator was designed to operate at temperatures ranging from 30 to 35 degrees Celsius. The total operating time of the system was 90 min, with a power consumption of 2647 watts. Experimental results indicated that the orchids were not adversely affected by the ozone exposure and that no chemical residues remained after treatment. Furthermore, the research evaluated the effectiveness of ozone fumigation against common orchid pests, namely aphids and red spider mites. When exposed to ozone concentrations ranging from 550 to 650 ppm for 60 min, the system achieved a 100% pest elimination rate for both species. These findings suggest that ozone treatment is a promising alternative to chemical pesticides for pest control in the orchid industry.
- 6 April 2026
- Published by MDPI AG in Applied Sciences
- Vol. 16 (7) , 3568
Open AccessApplication of Ozone Gas Technology for Extending Shelf Life and Controlling Pests in the Orchid and Grape Industries
This paper presents the application of ozone for pest control in large-scale systems, with the potential for industrial implementation. The designed ozone generation system is capable of producing an ozone concentration of 550 ppm within 30 min in a controlled chamber. Ozone technology was applied for the control of insect pests in the orchid export industry, both for current use and future applications. A high-concentration ozone generator was designed to operate at temperatures ranging from 30 to 35 degrees Celsius. The total operating time of the system was 90 min, with a power consumption of 2647 watts. Experimental results indicated that the orchids were not adversely affected by the ozone exposure and that no chemical residues remained after treatment. Furthermore, the research evaluated the effectiveness of ozone fumigation against common orchid pests, namely aphids and red spider mites. When exposed to ozone concentrations ranging from 550 to 650 ppm for 60 min, the system achieved a 100% pest elimination rate for both species. These findings suggest that ozone treatment is a promising alternative to chemical pesticides for pest control in the orchid industry.
- Open Access
- 5 June 2025
- Published by MDPI AG in Applied Sciences
- Vol. 15 (11) , 6357
Assessment of Transformer Fault Severity from Online Dissolved Gas Analysis Using Positive CUSUM
Dissolved gas analysis (DGA) is one of the transformer testing methods that has been widely used for a long time because it does not require the transformer to be offline for testing. The inspection can be conducted while the transformer is operating normally, and it is cost-effective. In research on fault severity, thermodynamic theory has been applied to find the energy index of the hydrocarbon gases generated by faults, , , and , referred to as the Normalised Energy Intensity (NEI). This study examines the application of the Positive Cumulative Sum of Difference (CUSUM) method to hydrocarbon NEI and carbon dioxide NEI for fault severity assessment. The study demonstrates the effectiveness of this approach by means of case studies on the basis of DGA results from two steel plants. In the case of NEI from hydrocarbon gases (), the positive CUSUM is compared with the NEI, the NEI score, and the cumulative NEI. In the case of NEI from carbon oxide gases (), Positive CUSUM is compared with NEI and the ratio of to . It was found that Positive CUSUM for is a much better indicator of the severity of defects than the NEI, the NEI score, and the cumulative NEI. In contrast, Positive CUSUM for gave excessively high values. However, combining NEI with the / ratio gave better monitoring results. Therefore, from an online DGA perspective, Positive CUSUM can be used to effectively monitor fault severity.- 5 June 2025
- Published by MDPI AG in Applied Sciences
- Vol. 15 (11) , 6357
Open AccessAssessment of Transformer Fault Severity from Online Dissolved Gas Analysis Using Positive CUSUM
Dissolved gas analysis (DGA) is one of the transformer testing methods that has been widely used for a long time because it does not require the transformer to be offline for testing. The inspection can be conducted while the transformer is operating normally, and it is cost-effective. In research on fault severity, thermodynamic theory has been applied to find the energy index of the hydrocarbon gases generated by faults, , , and , referred to as the Normalised Energy Intensity (NEI). This study examines the application of the Positive Cumulative Sum of Difference (CUSUM) method to hydrocarbon NEI and carbon dioxide NEI for fault severity assessment. The study demonstrates the effectiveness of this approach by means of case studies on the basis of DGA results from two steel plants. In the case of NEI from hydrocarbon gases (), the positive CUSUM is compared with the NEI, the NEI score, and the cumulative NEI. In the case of NEI from carbon oxide gases (), Positive CUSUM is compared with NEI and the ratio of to . It was found that Positive CUSUM for is a much better indicator of the severity of defects than the NEI, the NEI score, and the cumulative NEI. In contrast, Positive CUSUM for gave excessively high values. However, combining NEI with the / ratio gave better monitoring results. Therefore, from an online DGA perspective, Positive CUSUM can be used to effectively monitor fault severity. - Open Access
Power Distribution System Improvement Planning Considering Financial Losses Due to Faults in Power Systems
This research article presents a method for selecting an improvement approach for the power distribution system by analyzing financial losses caused by faults in the system. These losses can be in two parts: the first part arises from power outages, which lead to lost sales, estimated opportunities, and expenses for resolving the outages, while the second part results from voltage sags that affect sensitive electrical equipment. The method involves simulating faults at various points in the distribution system and assessing their impact on industrial, commercial, and large-scale electricity consumers. The results demonstrate that by combining the total financial losses from both parts and comparing these losses before and after implementing system improvements, effective and economically viable decision-making information can be obtained for enhancing the power distribution system.
Open AccessPower Distribution System Improvement Planning Considering Financial Losses Due to Faults in Power Systems
This research article presents a method for selecting an improvement approach for the power distribution system by analyzing financial losses caused by faults in the system. These losses can be in two parts: the first part arises from power outages, which lead to lost sales, estimated opportunities, and expenses for resolving the outages, while the second part results from voltage sags that affect sensitive electrical equipment. The method involves simulating faults at various points in the distribution system and assessing their impact on industrial, commercial, and large-scale electricity consumers. The results demonstrate that by combining the total financial losses from both parts and comparing these losses before and after implementing system improvements, effective and economically viable decision-making information can be obtained for enhancing the power distribution system.
- Open Access
Enhancing Voltage and Power Stability in Distribution System with Photovoltaic from the Benefits of Battery Energy Storage
This paper presents a method of enhancing voltage and power stability in a distribution system with the photovoltaic benefits of battery energy storage. The objective is to use photovoltaic-distributed generation and a battery energy storage system in order to reduce power loss to a minimum and generate a voltage up to or above 0.95 p.u, which is the voltage standard in Thailand. This paper used MATLAB (Version R2024b-acdemic use) to conduct test experiments, and the system for the case studies is an IEEE 33-bus radial distribution system. There are five study cases in this paper. Case 1 is before the installation of the photovoltaic and battery energy storage system. Case 2 is the installation of the photovoltaic-distributed generator in four buses. Case 3 is the installation of the photovoltaic-distributed generator in only one bus. Case 4 is the installation of the photovoltaic distributed generator in two buses that have the most voltage drop. Case 5 is the installation of the photovoltaic-distributing generator in four buses and the battery energy storage system in two buses. The results show that Case 5 is the best because the voltage drop is never below 0.95 per unit or below the lowest power loss.
Open AccessEnhancing Voltage and Power Stability in Distribution System with Photovoltaic from the Benefits of Battery Energy Storage
This paper presents a method of enhancing voltage and power stability in a distribution system with the photovoltaic benefits of battery energy storage. The objective is to use photovoltaic-distributed generation and a battery energy storage system in order to reduce power loss to a minimum and generate a voltage up to or above 0.95 p.u, which is the voltage standard in Thailand. This paper used MATLAB (Version R2024b-acdemic use) to conduct test experiments, and the system for the case studies is an IEEE 33-bus radial distribution system. There are five study cases in this paper. Case 1 is before the installation of the photovoltaic and battery energy storage system. Case 2 is the installation of the photovoltaic-distributed generator in four buses. Case 3 is the installation of the photovoltaic-distributed generator in only one bus. Case 4 is the installation of the photovoltaic distributed generator in two buses that have the most voltage drop. Case 5 is the installation of the photovoltaic-distributing generator in four buses and the battery energy storage system in two buses. The results show that Case 5 is the best because the voltage drop is never below 0.95 per unit or below the lowest power loss.
- Open Access
Simulation and Analysis of the Optimal Electric Field from Modifications to the Winding Design for the Tesla Transformer
This research aims to present a study of the effects of the Tesla transformer in order to find the proper dimensions. We created a design of the Tesla transformer to reduce the high-voltage electric field-stress problem that happens between primary winding and secondary winding. Because the Tesla transformer is used to induce voltage between these two windings through the air, problems with insulation occur. The winding that has space is dielectric; while there is high voltage in a transformer, it causes flashover voltage between the high-voltage winding and low-voltage winding, which damages the transformer and other devices. Research process: Research was conducted to study the laydown model (positioning) of the two windings in the transformer. By considering this, we induced a proper Tesla transformer that was reproduced by using the FEMLAB program. Moreover, we compared the Tesla transformer reproduction, which created a voltage of 120 kV and a frequency of 120 kHz. The result from the comparison is a proper laydown position of the primary winding and voltage, which has been designed without the flashover. The whorl coil has to be wound at a 60-degree angle relative to the floor and can induce more voltage than other models. The voltage and corresponding electric field stress were measured for the primary winding at various angles relative to the floor (0-, 30-, 45-, 60-, and 90-degree angles) to determine the configuration. The results from the reproduction using the FEMLAB program and testing demonstrated that no flashover occurred between the high-voltage winding to the low-voltage winding when the primary winding was positioned at a 60-degree angle.
Open AccessSimulation and Analysis of the Optimal Electric Field from Modifications to the Winding Design for the Tesla Transformer
This research aims to present a study of the effects of the Tesla transformer in order to find the proper dimensions. We created a design of the Tesla transformer to reduce the high-voltage electric field-stress problem that happens between primary winding and secondary winding. Because the Tesla transformer is used to induce voltage between these two windings through the air, problems with insulation occur. The winding that has space is dielectric; while there is high voltage in a transformer, it causes flashover voltage between the high-voltage winding and low-voltage winding, which damages the transformer and other devices. Research process: Research was conducted to study the laydown model (positioning) of the two windings in the transformer. By considering this, we induced a proper Tesla transformer that was reproduced by using the FEMLAB program. Moreover, we compared the Tesla transformer reproduction, which created a voltage of 120 kV and a frequency of 120 kHz. The result from the comparison is a proper laydown position of the primary winding and voltage, which has been designed without the flashover. The whorl coil has to be wound at a 60-degree angle relative to the floor and can induce more voltage than other models. The voltage and corresponding electric field stress were measured for the primary winding at various angles relative to the floor (0-, 30-, 45-, 60-, and 90-degree angles) to determine the configuration. The results from the reproduction using the FEMLAB program and testing demonstrated that no flashover occurred between the high-voltage winding to the low-voltage winding when the primary winding was positioned at a 60-degree angle.
- Open Access
- 20 December 2024
- Published by MDPI AG in Preprints.org
Power Distribution System Improvement Planning Considering Financial Losses Due to Faults in Power System
This research article presents a method for selecting an improvement approach for the power distribution system by analyzing financial losses caused by faults in the system. These losses can be estimated in two parts: the first part arises from power outages, which lead to lost sales opportunities and expenses for resolving the outages, while the second part results from voltage sags that affect sensitive electrical equipment. The method involves simulating faults at various points in the distribution system and assessing their impact on industrial, commercial, and largescale electricity consumers. The results demonstrate that by combining the total financial losses from both parts and comparing these losses before and after implementing system improvements, effective and economically viable decision-making information can be obtained for enhancing the power distribution system.
- 20 December 2024
- Published by MDPI AG in Preprints.org
Open AccessPower Distribution System Improvement Planning Considering Financial Losses Due to Faults in Power System
This research article presents a method for selecting an improvement approach for the power distribution system by analyzing financial losses caused by faults in the system. These losses can be estimated in two parts: the first part arises from power outages, which lead to lost sales opportunities and expenses for resolving the outages, while the second part results from voltage sags that affect sensitive electrical equipment. The method involves simulating faults at various points in the distribution system and assessing their impact on industrial, commercial, and largescale electricity consumers. The results demonstrate that by combining the total financial losses from both parts and comparing these losses before and after implementing system improvements, effective and economically viable decision-making information can be obtained for enhancing the power distribution system.
- Open Access
- 10 December 2024
- Published by MDPI AG in Preprints.org
Enhancing Voltage and Power Stability in Distribution System with Photovoltaic from Benefits of Battery Energy Storage
This paper presents enhancing voltage and power stability in distribution system with photovoltaic from benefits of battery energy storage. This objective which is use photovoltaic distributed generation and battery energy storage system in order to reduce electric power loss to minimum loss and generate voltage up to or above 0.95 p.u which is thailand voltage standard. This paper has experiment in MATLAB test in the system for the case study is a IEEE 33 bus distribution system. There are 5 study case in this paper. Case 1 is before installation photovoltaic and battery energy storage system. Case 2 is installation photovoltaic distributed generator in 4 buses. Case 3 is installation photovoltaic distributed generator in only one bus. Case 4 is installation photovoltaic distributed generator in 2 buses that have most voltage drop. Case 5 is installation photovoltaic distributed generator in 4 buses and battery energy storage system in 2 buses. The result show case 5 is the best because none numbers of voltage drop is below 0.95 per unit and the lowest power loss.
- 10 December 2024
- Published by MDPI AG in Preprints.org
Open AccessEnhancing Voltage and Power Stability in Distribution System with Photovoltaic from Benefits of Battery Energy Storage
This paper presents enhancing voltage and power stability in distribution system with photovoltaic from benefits of battery energy storage. This objective which is use photovoltaic distributed generation and battery energy storage system in order to reduce electric power loss to minimum loss and generate voltage up to or above 0.95 p.u which is thailand voltage standard. This paper has experiment in MATLAB test in the system for the case study is a IEEE 33 bus distribution system. There are 5 study case in this paper. Case 1 is before installation photovoltaic and battery energy storage system. Case 2 is installation photovoltaic distributed generator in 4 buses. Case 3 is installation photovoltaic distributed generator in only one bus. Case 4 is installation photovoltaic distributed generator in 2 buses that have most voltage drop. Case 5 is installation photovoltaic distributed generator in 4 buses and battery energy storage system in 2 buses. The result show case 5 is the best because none numbers of voltage drop is below 0.95 per unit and the lowest power loss.
- Open Access
Shortening the Payback Period of Greenhouse Gas Reduction Benefits from Photovoltaic Rooftop Systems
This paper presents an analysis of shortening the payback period of greenhouse gas reduction benefits from photovoltaic rooftop systems. The objective was to evaluate the amount of carbon credits generated and their returns. The study includes an economic analysis and a comparison of the economic outcomes with and without the consideration of carbon credits from 149.80 kWp and 25.68 kWp photovoltaic rooftop systems. The study evaluated the amount of electrical energy produced by the photovoltaic rooftop systems, estimated using the PVsyst program version 7.3.1, at a factory in Pathum Thani Province, Thailand. The economic indices analyzed in this study include the payback period, net present value (NPV), benefit–cost ratio (B/C ratio), and internal rate of return (IRR). The analysis is divided into four case studies: Case 1 is the base case, and Cases 2, 3, and 4 consider carbon credits for 7, 14, and 25 years, respectively. The economic indices analyzed in Case 1 include the financial internal rate of return (FIRR), payback period, financial net present value (FNPV), and B/C ratio. In Cases 2, 3, and 4, the economic indices analyzed are the economic internal rate of return (EIRR), the economic net present value (ENPV), the B/C ratio, and the payback period. This paper outlines a new economic calculation approach that incorporates carbon credits produced by photovoltaic rooftop systems, which helps achieve break-even points more quickly. It also discusses the application of carbon credits in conjunction with renewable energy.
Open AccessShortening the Payback Period of Greenhouse Gas Reduction Benefits from Photovoltaic Rooftop Systems
This paper presents an analysis of shortening the payback period of greenhouse gas reduction benefits from photovoltaic rooftop systems. The objective was to evaluate the amount of carbon credits generated and their returns. The study includes an economic analysis and a comparison of the economic outcomes with and without the consideration of carbon credits from 149.80 kWp and 25.68 kWp photovoltaic rooftop systems. The study evaluated the amount of electrical energy produced by the photovoltaic rooftop systems, estimated using the PVsyst program version 7.3.1, at a factory in Pathum Thani Province, Thailand. The economic indices analyzed in this study include the payback period, net present value (NPV), benefit–cost ratio (B/C ratio), and internal rate of return (IRR). The analysis is divided into four case studies: Case 1 is the base case, and Cases 2, 3, and 4 consider carbon credits for 7, 14, and 25 years, respectively. The economic indices analyzed in Case 1 include the financial internal rate of return (FIRR), payback period, financial net present value (FNPV), and B/C ratio. In Cases 2, 3, and 4, the economic indices analyzed are the economic internal rate of return (EIRR), the economic net present value (ENPV), the B/C ratio, and the payback period. This paper outlines a new economic calculation approach that incorporates carbon credits produced by photovoltaic rooftop systems, which helps achieve break-even points more quickly. It also discusses the application of carbon credits in conjunction with renewable energy.
- Open Access
- 25 November 2024
- Published by MDPI AG in Preprints.org
Analysis of Electric Field Distribution on Primary Windings of High-Voltage High-Frequency Transformers with Variables Characteristics
This paper present analysis of electric field distribution on windings of primary side of high frequency, and voltage transformers with variables characteristics. To study the effect of high transformer voltage, induce and high frequency for finding suitable dimension. The objective is analysis of electricity field distribution at the low voltage at the angle 0, 30, 45, 60, and 90 degrees, Comparing voltage flow out of the putting primary coil. Comparing external frequency of primary coil putting. Comparing result of distribution electricity field model between primary coil (Lp) and secondary coil. By consideration from induce that proper for Tesla transformer reproduce by using FEMLAB program. Comparing the Tesla transformer reproduce which is created the frequency 120 kHz and voltage at 120 kV. Analysis use FEMLAB program. The result isn’t flash over between the low and high voltage winding.
- 25 November 2024
- Published by MDPI AG in Preprints.org
Open AccessAnalysis of Electric Field Distribution on Primary Windings of High-Voltage High-Frequency Transformers with Variables Characteristics
This paper present analysis of electric field distribution on windings of primary side of high frequency, and voltage transformers with variables characteristics. To study the effect of high transformer voltage, induce and high frequency for finding suitable dimension. The objective is analysis of electricity field distribution at the low voltage at the angle 0, 30, 45, 60, and 90 degrees, Comparing voltage flow out of the putting primary coil. Comparing external frequency of primary coil putting. Comparing result of distribution electricity field model between primary coil (Lp) and secondary coil. By consideration from induce that proper for Tesla transformer reproduce by using FEMLAB program. Comparing the Tesla transformer reproduce which is created the frequency 120 kHz and voltage at 120 kV. Analysis use FEMLAB program. The result isn’t flash over between the low and high voltage winding.
- Open Access
- 25 October 2024
- Published by MDPI AG in Preprints.org
Shortening the Payback Period of Greenhouse Gas Reduction Benefits from Photovoltaic Rooftop System
This paper presents shortening the payback period of greenhouse gas reduction benefits from photovoltaic rooftop system. The objective was to evaluate the amount and returns of carbon credits. Economic analysis, and comparison of economic analysis with and without consideration of carbon credits from a 149.80 kWp, and 25.68 kWp photovoltaic rooftop system. This study evaluated the amount of electrical energy produced by a photovoltaic rooftop system estimated from the PVsyst program of the factory in Pathum Thani Province, Thailand. The economic indices that the researcher analyzed include the payback period, net present value (NPV), benefit cost ratio (B/C ratio), internal rate of return (IRR). It is divided into four cases studies: Case 1 is the base case, and Cases 2, 3, and 4 are considered carbon credits for 7, 14, and 25 years, respectively. The economic indices analyzed in Case 1 include financial internal rate of return (FIRR), payback period, financial net present value (FNPV), and B/C ratio. The economic indices analyzed in Cases 2, 3, and 4 are the economic internal rate of return (EIRR), economic net present value (ENPV), B/C ratio, payback periods, respectively. This paper outlines a new economic calculation approach that considers carbon credits produced by photovoltaic rooftop system to reach break-even points more quickly, and the application of carbon credits in conjunction with renewable energy.
- 25 October 2024
- Published by MDPI AG in Preprints.org
Open AccessShortening the Payback Period of Greenhouse Gas Reduction Benefits from Photovoltaic Rooftop System
This paper presents shortening the payback period of greenhouse gas reduction benefits from photovoltaic rooftop system. The objective was to evaluate the amount and returns of carbon credits. Economic analysis, and comparison of economic analysis with and without consideration of carbon credits from a 149.80 kWp, and 25.68 kWp photovoltaic rooftop system. This study evaluated the amount of electrical energy produced by a photovoltaic rooftop system estimated from the PVsyst program of the factory in Pathum Thani Province, Thailand. The economic indices that the researcher analyzed include the payback period, net present value (NPV), benefit cost ratio (B/C ratio), internal rate of return (IRR). It is divided into four cases studies: Case 1 is the base case, and Cases 2, 3, and 4 are considered carbon credits for 7, 14, and 25 years, respectively. The economic indices analyzed in Case 1 include financial internal rate of return (FIRR), payback period, financial net present value (FNPV), and B/C ratio. The economic indices analyzed in Cases 2, 3, and 4 are the economic internal rate of return (EIRR), economic net present value (ENPV), B/C ratio, payback periods, respectively. This paper outlines a new economic calculation approach that considers carbon credits produced by photovoltaic rooftop system to reach break-even points more quickly, and the application of carbon credits in conjunction with renewable energy.