Andrew John Ruys
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Andrew John Ruys has a total of 37 co-authors. Here are the top co-authors by number of shared publications:
- Philip Boughton
The University of Sydney
5 shared publications Elizabeth C. Kolos
University of Sydney
2 shared publicationsG. Roger
Advanced Surgical Design and Manufacture Pty Ltd
2 shared publicationsGreg J. Roger
2 shared publications- Adhi Anindyajati
Department of Industrial Engineering, Universitas Atma Jaya Yogyakarta, Yogyakarta, Indonesia
1 shared publication Angela Hong
The University of Sydney
1 shared publication
Latest Publications
- Open Access
- 14 July 2017
- Published by Trans Tech Publications, Ltd. in Materials Science Forum
- Vol. 900, 17-22
Fabrication and Microstructure Evaluation of Fibrous Composite for Acetabular Labrum Implant
This paper will report the fabrication process and microstructure analysis of fibrous composite incorporating ultra-high molecular weight polyethylene (UHMWPE) fabric, electrospun polycaprolactone (PCL), and bioglass particles. Briefly, electrospinning was performed to form PCL fibre lamination in the surface of UHMWPE fabric. This UHMWPE/PCL material was then bioglass-coated. Sequentially, microstructure of the UHMWPE fabric, UHMWPE/PCL, and UHMWPE/PCL/bioglass was imaged and analysed. The composite showed aligned ultrafine PCL fibres and distribution of bioglass particles in the layer of electrospun PCL. The results of this study provide groundwork for more advanced investigation, as well as development of implant prototype.
- 14 July 2017
- Published by Trans Tech Publications, Ltd. in Materials Science Forum
- Vol. 900, 17-22
Open AccessFabrication and Microstructure Evaluation of Fibrous Composite for Acetabular Labrum Implant
This paper will report the fabrication process and microstructure analysis of fibrous composite incorporating ultra-high molecular weight polyethylene (UHMWPE) fabric, electrospun polycaprolactone (PCL), and bioglass particles. Briefly, electrospinning was performed to form PCL fibre lamination in the surface of UHMWPE fabric. This UHMWPE/PCL material was then bioglass-coated. Sequentially, microstructure of the UHMWPE fabric, UHMWPE/PCL, and UHMWPE/PCL/bioglass was imaged and analysed. The composite showed aligned ultrafine PCL fibres and distribution of bioglass particles in the layer of electrospun PCL. The results of this study provide groundwork for more advanced investigation, as well as development of implant prototype.
- Open Access
- 22 December 2016
- Published by Materials Research Forum, LLC
- Vol. 2, 545-550
Neutron Diffraction Measurements of Residual Stress and Mechanical Testing of Pressure Sintered Metal-Ceramic Composite Systems
- 22 December 2016
- Published by Materials Research Forum, LLC
- Vol. 2, 545-550
Open AccessNeutron Diffraction Measurements of Residual Stress and Mechanical Testing of Pressure Sintered Metal-Ceramic Composite Systems
- 13 December 2012
- Published by Trans Tech Publications, Ltd. in Journal of Biomimetics, Biomaterials and Tissue Engineering
- Vol. 16, 83-95
A Novel Patient-Specific Regenerative Meniscal Replacement System
Knee meniscal injuries account for the greatest number of surgical procedures performed by orthopaedic surgeons worldwide. Each year in excess of 400,000 operations are performed in Europe and over one million in the United States and yet no suitable replacement for the meniscus is available. Fibrocartilage tissue engineering holds great potential in the regeneration of meniscal tissue however current developments have been limited. Difficulties in imitating the anisotropic nature of the meniscus, patient specific geometry, attaining sterility assurance requirements remain as developmental challenges for meniscal scaffold devices. A novel approach was developed to rapidly form terminally sterilized pre-packaged scaffold templates into anatomically matched regenerative meniscal implants. Formed meniscal implants exhibited the structural and functional architecture of the native meniscus. Meniscal implants fabricated using this method displayed mechanical properties approaching to that of the native meniscus and imparted rotational stability. Fixation techniques influenced the biomechanical response of implants and 45S5 bioactive glass modification was found to enhance radio-opacity of the scaffold. Biocompatibility of the implant was confirmed using a fibroblast cell culture model.
- 13 December 2012
- Published by Trans Tech Publications, Ltd. in Journal of Biomimetics, Biomaterials and Tissue Engineering
- Vol. 16, 83-95
A Novel Patient-Specific Regenerative Meniscal Replacement System
Knee meniscal injuries account for the greatest number of surgical procedures performed by orthopaedic surgeons worldwide. Each year in excess of 400,000 operations are performed in Europe and over one million in the United States and yet no suitable replacement for the meniscus is available. Fibrocartilage tissue engineering holds great potential in the regeneration of meniscal tissue however current developments have been limited. Difficulties in imitating the anisotropic nature of the meniscus, patient specific geometry, attaining sterility assurance requirements remain as developmental challenges for meniscal scaffold devices. A novel approach was developed to rapidly form terminally sterilized pre-packaged scaffold templates into anatomically matched regenerative meniscal implants. Formed meniscal implants exhibited the structural and functional architecture of the native meniscus. Meniscal implants fabricated using this method displayed mechanical properties approaching to that of the native meniscus and imparted rotational stability. Fixation techniques influenced the biomechanical response of implants and 45S5 bioactive glass modification was found to enhance radio-opacity of the scaffold. Biocompatibility of the implant was confirmed using a fibroblast cell culture model.
- 26 July 2012
- Published by Trans Tech Publications, Ltd. in Journal of Biomimetics, Biomaterials and Tissue Engineering
- Vol. 14, 31-42
A Novel Dynamic 3-Dimensional Construct for Respiratory Tissue Engineering
Tissue engineering of airway tissues poses many complex challenges. As tissue form is determined by function and vice versa, it is necessary to consider mechanical and physiological constraints in conjunction with standard biologic and biochemical factors when culturing tissues in vitro. This study involved the development and validation of a novel 3-dimensional (3-D) construct with the capacity to periodically expose a cell scaffold to air and medium at application of physiologic strain rates. The ultimate objective was to mimic respiratory conditions experienced by airway tissues during breathing whilst ensuring compatibility with proven cell culture techniques. The Biaxx design consists of an elastomeric porous synthetic scaffold integrated with a unique biopolymer coupling unit which engages with an IAXSYS bioreactor actuator. Uniform biaxial strain was imparted by the coupling unit whilst simultaneously creating a periodic air-liquid interface. Biaxx scaffolds with and without a coating of particulate 45S5 bioglass were employed in an assay to assess cell attachment and proliferation whilst subject to periodic strain. Physiologic lung tissue strain of 5-15% was achieved for over 200,000 cycles at 0.2Hz. Preliminary biological studies with H460 human lung carcinoma cells confirmed cell attachment, growth and proliferation on this promising construct.
- 26 July 2012
- Published by Trans Tech Publications, Ltd. in Journal of Biomimetics, Biomaterials and Tissue Engineering
- Vol. 14, 31-42
A Novel Dynamic 3-Dimensional Construct for Respiratory Tissue Engineering
Tissue engineering of airway tissues poses many complex challenges. As tissue form is determined by function and vice versa, it is necessary to consider mechanical and physiological constraints in conjunction with standard biologic and biochemical factors when culturing tissues in vitro. This study involved the development and validation of a novel 3-dimensional (3-D) construct with the capacity to periodically expose a cell scaffold to air and medium at application of physiologic strain rates. The ultimate objective was to mimic respiratory conditions experienced by airway tissues during breathing whilst ensuring compatibility with proven cell culture techniques. The Biaxx design consists of an elastomeric porous synthetic scaffold integrated with a unique biopolymer coupling unit which engages with an IAXSYS bioreactor actuator. Uniform biaxial strain was imparted by the coupling unit whilst simultaneously creating a periodic air-liquid interface. Biaxx scaffolds with and without a coating of particulate 45S5 bioglass were employed in an assay to assess cell attachment and proliferation whilst subject to periodic strain. Physiologic lung tissue strain of 5-15% was achieved for over 200,000 cycles at 0.2Hz. Preliminary biological studies with H460 human lung carcinoma cells confirmed cell attachment, growth and proliferation on this promising construct.
- 16 January 2011
- Published by Trans Tech Publications, Ltd. in Journal of Biomimetics, Biomaterials and Tissue Engineering
- Vol. 9, 81-91
Development of a Bioabsorbable Glass-Reinforced-Glass Intra-Osseous Scaffold for Fracture Healing
Intramedullary (IM) nails are routinely used to stabilize long bone fractures. They can however lead to stress shielding, pain, migration, obstruct hematopoietic tissue, become a loci for infection, and require subsequent surgical retrieval. Novel intra-osseous scaffold (IOS™) prototypes for fracture healing have been developed to function as a regenerative scaffold to enhance callous formation under mechanically stabilized conditions then resorb. Prototype fixation pins and rod systems were formed from glass-reinforced-glass. Flexion, torsion and shear tests were performed to evaluate the composite pins and rods. A modular rod design was successfully deployed and dilated while in a deformable state. When fitted and gripping the intramedullary canal then set in a rigid state. An obliquely sectioned ovine femur was used as a long bone fracture model for deployment and mechanical verification. Flexural support provided by the intramedullary scaffold was superior to multiple k-wire fixation, while the k-wire approach was more stabilizing under torsional loads. Glass reinforced glass samples were mechanically tested after soaking for up to 4 weeks in saline. Strength and modulus of the composite was reduced to approximately 25% of initial values after 2 weeks.
- 16 January 2011
- Published by Trans Tech Publications, Ltd. in Journal of Biomimetics, Biomaterials and Tissue Engineering
- Vol. 9, 81-91
Development of a Bioabsorbable Glass-Reinforced-Glass Intra-Osseous Scaffold for Fracture Healing
Intramedullary (IM) nails are routinely used to stabilize long bone fractures. They can however lead to stress shielding, pain, migration, obstruct hematopoietic tissue, become a loci for infection, and require subsequent surgical retrieval. Novel intra-osseous scaffold (IOS™) prototypes for fracture healing have been developed to function as a regenerative scaffold to enhance callous formation under mechanically stabilized conditions then resorb. Prototype fixation pins and rod systems were formed from glass-reinforced-glass. Flexion, torsion and shear tests were performed to evaluate the composite pins and rods. A modular rod design was successfully deployed and dilated while in a deformable state. When fitted and gripping the intramedullary canal then set in a rigid state. An obliquely sectioned ovine femur was used as a long bone fracture model for deployment and mechanical verification. Flexural support provided by the intramedullary scaffold was superior to multiple k-wire fixation, while the k-wire approach was more stabilizing under torsional loads. Glass reinforced glass samples were mechanically tested after soaking for up to 4 weeks in saline. Strength and modulus of the composite was reduced to approximately 25% of initial values after 2 weeks.
- 25 October 2010
- Published by Trans Tech Publications, Ltd. in Journal of Biomimetics, Biomaterials and Tissue Engineering
- Vol. 7, 55-79
An Interlocking Ligamentous Spinal Disk Arthroplasty with Neural Network Infrastructure
An elastomeric spinal disk prosthesis design (BioFI™) with vertebral interlocking anchors has been modified using an embedded TiNi wire array. Bioinert styrenic block copolymer (Kraton®) and polycarbonate urethane (Bionate®) thermoplastic elastomer (TPE) matrices were utilized. Fatigue resistant NiTi wire was pretreated to induce superelastic martensitic microstructure. Stent-like helical structures were produced for incorporation within homogenous TPE matrix. Composite prototypes were fabricated in a vacuum hot press using transfer moulding techniques. Implant prototypes were subject to axial compression using a BOSE ® ELF3400. The NiTi reinforced implants exhibited reduction in axial strain, compliance, and creep compared to TPE controls. The axial properties of the NiTi reinforced Bionate® BioFI™ implant best approximated those of a spinal disk followed by Kraton®-NiTi, Bionate® and Kraton® prototypes. An ovine lumbar segment biomechanical model was used to characterize the disk prosthesis prototypes. Specimens were subject to 7.5Nm pure moments in axial rotation, flexion-extension and lateral bending with a custom jig mounted on an Instron® 8874. The motion preserving ligamentous nature of this arthroplasty prototype was not inhibited by NiTi reinforcement. Joint stiffness for all prototypes was significantly less than the intact and discectomy controls. This was due to lack of vertebral anchor rigidity rather than BioFI™ motion segment matrix type or reinforcement. Implant stress profiles for axial compression and axial torsion conditions were obtained using finite element methods. The biomechanical testing and finite element modelling both support existing BioFI™ design specifications for higher modulus vertebral anchors, endplates and motion segment periphery with gradation to a low modulus core within the motion segment. This closer approximation of the native spinal disk form translates to improvements in prosthesis biomechanical fidelity and longevity. Axial compressive strain induced within a TiNi reinforced Kraton® BioFI™ was found to be linearly proportional to the NiTi helical coil electrical resistance. This neural network capability delivers opportunities to monitor and telemeterize in situ multiaxis joint structural performance and in vivo spine biomechanics.
- 25 October 2010
- Published by Trans Tech Publications, Ltd. in Journal of Biomimetics, Biomaterials and Tissue Engineering
- Vol. 7, 55-79
An Interlocking Ligamentous Spinal Disk Arthroplasty with Neural Network Infrastructure
An elastomeric spinal disk prosthesis design (BioFI™) with vertebral interlocking anchors has been modified using an embedded TiNi wire array. Bioinert styrenic block copolymer (Kraton®) and polycarbonate urethane (Bionate®) thermoplastic elastomer (TPE) matrices were utilized. Fatigue resistant NiTi wire was pretreated to induce superelastic martensitic microstructure. Stent-like helical structures were produced for incorporation within homogenous TPE matrix. Composite prototypes were fabricated in a vacuum hot press using transfer moulding techniques. Implant prototypes were subject to axial compression using a BOSE ® ELF3400. The NiTi reinforced implants exhibited reduction in axial strain, compliance, and creep compared to TPE controls. The axial properties of the NiTi reinforced Bionate® BioFI™ implant best approximated those of a spinal disk followed by Kraton®-NiTi, Bionate® and Kraton® prototypes. An ovine lumbar segment biomechanical model was used to characterize the disk prosthesis prototypes. Specimens were subject to 7.5Nm pure moments in axial rotation, flexion-extension and lateral bending with a custom jig mounted on an Instron® 8874. The motion preserving ligamentous nature of this arthroplasty prototype was not inhibited by NiTi reinforcement. Joint stiffness for all prototypes was significantly less than the intact and discectomy controls. This was due to lack of vertebral anchor rigidity rather than BioFI™ motion segment matrix type or reinforcement. Implant stress profiles for axial compression and axial torsion conditions were obtained using finite element methods. The biomechanical testing and finite element modelling both support existing BioFI™ design specifications for higher modulus vertebral anchors, endplates and motion segment periphery with gradation to a low modulus core within the motion segment. This closer approximation of the native spinal disk form translates to improvements in prosthesis biomechanical fidelity and longevity. Axial compressive strain induced within a TiNi reinforced Kraton® BioFI™ was found to be linearly proportional to the NiTi helical coil electrical resistance. This neural network capability delivers opportunities to monitor and telemeterize in situ multiaxis joint structural performance and in vivo spine biomechanics.
- 8 December 2009
- Published by Trans Tech Publications, Ltd. in Journal of Biomimetics, Biomaterials and Tissue Engineering
- Vol. 4, 21-26
Characterisation of Foamed Porous Alumina Tissue Scaffolds
A porous tissue scaffold depends on its ability to provide functional balance between mechanical strength, pore properties and interconnectivity of pores. High porosity levels, typically greater than 90% and pore sizes above 100µm are required for tissue growth and fixation. Alumina is a stable and very strong bioceramic which, when doped with calcium and phosphate ions, can potentially combine bioactivity with high porosity and high strength. Highly porous alumina foams were synthesized through heat induced chemical breakdown of precursor salt solutions. Pore sizes achieved for foamed alumina with moderate mole fractions are generally larger than 100µm. Foamed alumina with mole fractions on the extreme high and low ends shows lower average pore sizes. Compressive strength of synthesized foams falls in the range of 100kPa to 230kPa, significantly higher than porous biodegradable polymer tissue scaffolds. The significance of this work is that scaffolds can be produced with the unique combination of high porosity, high strength and biocompatibility.
- 8 December 2009
- Published by Trans Tech Publications, Ltd. in Journal of Biomimetics, Biomaterials and Tissue Engineering
- Vol. 4, 21-26
Characterisation of Foamed Porous Alumina Tissue Scaffolds
A porous tissue scaffold depends on its ability to provide functional balance between mechanical strength, pore properties and interconnectivity of pores. High porosity levels, typically greater than 90% and pore sizes above 100µm are required for tissue growth and fixation. Alumina is a stable and very strong bioceramic which, when doped with calcium and phosphate ions, can potentially combine bioactivity with high porosity and high strength. Highly porous alumina foams were synthesized through heat induced chemical breakdown of precursor salt solutions. Pore sizes achieved for foamed alumina with moderate mole fractions are generally larger than 100µm. Foamed alumina with mole fractions on the extreme high and low ends shows lower average pore sizes. Compressive strength of synthesized foams falls in the range of 100kPa to 230kPa, significantly higher than porous biodegradable polymer tissue scaffolds. The significance of this work is that scaffolds can be produced with the unique combination of high porosity, high strength and biocompatibility.
- 21 July 2009
- Published by Trans Tech Publications, Ltd. in Journal of Biomimetics, Biomaterials and Tissue Engineering
- Vol. 3, 37-49
Biomimetic Functionally Graded Materials: Synthesis by Impeller-Dry-Blending
Functionally graded materials (FGMs) can be found naturally in many biological structures, for example bamboo and the mollusc shell. They are defined as having a compositional or microstructural gradient, for example the gradation in fibre content in bamboo stems. A continuous bulk functionally graded material has the potential to be an ideal orthopaedic implant for load bearing applications. Due to the fabrication complexities involved in the production of these continuous bulk functionally graded materials, commercialisation and fabrication are still proving to be a challenge to researchers worldwide. This paper presents an overview of the redesigned novel commercially viable process known as the Impeller-Dry-Blending (IDB) process. Results presented in this paper of fabricated functionally graded materials illustrate the potential of IDB to produce continuous bulk functionally graded materials consisting of either compositional or porosity concentration changes. The successful fabrication of these continuous bulk functionally graded materials at such a low cost clearly demonstrates the commercial viability of the IDB process.
- 21 July 2009
- Published by Trans Tech Publications, Ltd. in Journal of Biomimetics, Biomaterials and Tissue Engineering
- Vol. 3, 37-49
Biomimetic Functionally Graded Materials: Synthesis by Impeller-Dry-Blending
Functionally graded materials (FGMs) can be found naturally in many biological structures, for example bamboo and the mollusc shell. They are defined as having a compositional or microstructural gradient, for example the gradation in fibre content in bamboo stems. A continuous bulk functionally graded material has the potential to be an ideal orthopaedic implant for load bearing applications. Due to the fabrication complexities involved in the production of these continuous bulk functionally graded materials, commercialisation and fabrication are still proving to be a challenge to researchers worldwide. This paper presents an overview of the redesigned novel commercially viable process known as the Impeller-Dry-Blending (IDB) process. Results presented in this paper of fabricated functionally graded materials illustrate the potential of IDB to produce continuous bulk functionally graded materials consisting of either compositional or porosity concentration changes. The successful fabrication of these continuous bulk functionally graded materials at such a low cost clearly demonstrates the commercial viability of the IDB process.
- 18 May 2009
- Published by Trans Tech Publications, Ltd. in Journal of Biomimetics, Biomaterials and Tissue Engineering
- Vol. 2, 73-93
Biomimetic Design of Haute-Temperature Lightweight Ceramics: A Review
Functionally graded materials (FGMs) are composite materials in which the properties are varied continuously from one face to the other via a compositional gradient. Functionally graded structures can be found in nature as evident in the cross-sections of bone, teeth and many plant stems, for example bamboo. Initially conceived for the purpose of thermal barrier coatings on spaceplanes, FGMs are finding more applications in other fields such as in polymers, biomedical and semiconductors. In this review, we take a look at two kinds of ceramics, carbon-carbon and fused silica, their properties and processing methods, as well as the possibility of incorporating them in a functionally graded material for use in high-temperature applications. Both carbon and fused silica have similarly low thermal expansion coefficients which will (1) allow the degree of thermal mismatch between the graded layers to be minimized and; (2) reduce the thermomechanical shock that will occur in the presence of a steep temperature gradient.
- 18 May 2009
- Published by Trans Tech Publications, Ltd. in Journal of Biomimetics, Biomaterials and Tissue Engineering
- Vol. 2, 73-93
Biomimetic Design of Haute-Temperature Lightweight Ceramics: A Review
Functionally graded materials (FGMs) are composite materials in which the properties are varied continuously from one face to the other via a compositional gradient. Functionally graded structures can be found in nature as evident in the cross-sections of bone, teeth and many plant stems, for example bamboo. Initially conceived for the purpose of thermal barrier coatings on spaceplanes, FGMs are finding more applications in other fields such as in polymers, biomedical and semiconductors. In this review, we take a look at two kinds of ceramics, carbon-carbon and fused silica, their properties and processing methods, as well as the possibility of incorporating them in a functionally graded material for use in high-temperature applications. Both carbon and fused silica have similarly low thermal expansion coefficients which will (1) allow the degree of thermal mismatch between the graded layers to be minimized and; (2) reduce the thermomechanical shock that will occur in the presence of a steep temperature gradient.
- 15 December 2003
- Published by Trans Tech Publications, Ltd. in Key Engineering Materials
- Vol. 254-256, 343-346
Novel Calcium Phosphate Fibres from a Biomimetic Process: Manufacture and Cell Attachment
- 15 December 2003
- Published by Trans Tech Publications, Ltd. in Key Engineering Materials
- Vol. 254-256, 343-346
Novel Calcium Phosphate Fibres from a Biomimetic Process: Manufacture and Cell Attachment