Aravind Manjeri
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Aravind Manjeri has a total of 5 co-authors. Here are the top co-authors by number of shared publications:
- Sajan Daniel George
Manipal Academy of Higher Education
4 shared publications Ankur Saxena
Department of Mechanical Engineering, Manipal University Jaipur, Jaipur, India
1 shared publicationDhaneshwar Mishra
Department of Mechanical Engineering, Manipal University Jaipur, Jaipur, India
1 shared publication- Haider Butt
Department of Mechanical and Nuclear Engineering, Khalifa University of Science and Technology, Abu Dhabi, UAE
1 shared publication Kulwant Singh
Skill Faculty of Engineering & Technology, Shri Vishwakarma Skill University, Palwal, India
1 shared publication
Latest Publications
- Open Access
- 16 April 2025
- Published by Royal Society of Chemistry (RSC) in RSC Advances
- Vol. 15 (16) , 12765-12772
In situ reduced gold nanoparticles in PDMS contact lenses for color blindness management
Color vision deficiency, or color blindness, is an ocular condition in which individuals have difficulty distinguishing between certain colors. While there is currently no cure for this condition, various wearables can be used to improve the color perception of those affected. The most common wearables used are color-filtering glasses and lenses, which filter out the problematic wavelengths. The most prevalent form of color vision deficiency is red-green color blindness. In this study, gold nanoparticles were in situ reduced onto contact lens material, forming plasmonic contact lenses targeted for red-green color blindness management. The absorption of the plasmonic particles, which peaked at around 533 nm, filtered out specific wavelengths to significantly enhance the color perception of both deuteranopia and protanopia. The study also presented an approach of imaging through the plasmonic lenses, followed by color blindness vision simulation to replicate a colorblind individual's vision. When combined with the Ishihara test, this approach proved to effectively improve color perception with the use of plasmonic contact lenses. The study presents a facile method for creating stable, hydrophilic plasmonic contact lenses to manage color blindness. It also offers a unique way to simulate the impact of color filtering on the vision of individuals with color blindness.
- 16 April 2025
- Published by Royal Society of Chemistry (RSC) in RSC Advances
- Vol. 15 (16) , 12765-12772
Open AccessIn situ reduced gold nanoparticles in PDMS contact lenses for color blindness management
Color vision deficiency, or color blindness, is an ocular condition in which individuals have difficulty distinguishing between certain colors. While there is currently no cure for this condition, various wearables can be used to improve the color perception of those affected. The most common wearables used are color-filtering glasses and lenses, which filter out the problematic wavelengths. The most prevalent form of color vision deficiency is red-green color blindness. In this study, gold nanoparticles were in situ reduced onto contact lens material, forming plasmonic contact lenses targeted for red-green color blindness management. The absorption of the plasmonic particles, which peaked at around 533 nm, filtered out specific wavelengths to significantly enhance the color perception of both deuteranopia and protanopia. The study also presented an approach of imaging through the plasmonic lenses, followed by color blindness vision simulation to replicate a colorblind individual's vision. When combined with the Ishihara test, this approach proved to effectively improve color perception with the use of plasmonic contact lenses. The study presents a facile method for creating stable, hydrophilic plasmonic contact lenses to manage color blindness. It also offers a unique way to simulate the impact of color filtering on the vision of individuals with color blindness.
- Open Access
- 3 April 2025
- Published by Springer Nature in Microsystems & Nanoengineering
- Vol. 11 (1) , 1-16
Microfluidic contact lens: fabrication approaches and applications
Microfluidic contact lenses integrate microscale features that can efficiently and precisely manipulate, interact, and analyze the small volumes of tears available in the limited accessible space for the lens in the eye. The microfluidic network on contact lenses allows the miniaturization of biochemical operations on the wealth of physiological information available in the eye. Sensors integrated into channels enable real-time monitoring of ocular parameters, including glucose, pH, electrolytes, or other biomarkers. Additionally, microchannel-integrated contact lenses have demonstrated potential as power-free, continuous intraocular pressure monitoring platforms for the effective management of glaucoma. Furthermore, the controlled release of medications directly onto the eye from microfluidic contact lenses enhances therapeutic efficacy by increasing bioavailability. Despite current challenges such as scalable fabrication techniques, microfluidic contact lenses hold immense promise for ocular health, bridging the gap between diagnostics and treatment. This review summarizes the progress made in the design and fabrication of microfluidic contact lenses, with a special emphasis on the methods adopted to fabricate microfluidic contact lenses. Furthermore, the various applications of microfluidic contact lenses, ocular disease diagnosis, and drug delivery in particular are discussed in detail. Aside from outlining the state-of-the-art research activities in this area, challenges and future directions are discussed here.
- 3 April 2025
- Published by Springer Nature in Microsystems & Nanoengineering
- Vol. 11 (1) , 1-16
Open AccessMicrofluidic contact lens: fabrication approaches and applications
Microfluidic contact lenses integrate microscale features that can efficiently and precisely manipulate, interact, and analyze the small volumes of tears available in the limited accessible space for the lens in the eye. The microfluidic network on contact lenses allows the miniaturization of biochemical operations on the wealth of physiological information available in the eye. Sensors integrated into channels enable real-time monitoring of ocular parameters, including glucose, pH, electrolytes, or other biomarkers. Additionally, microchannel-integrated contact lenses have demonstrated potential as power-free, continuous intraocular pressure monitoring platforms for the effective management of glaucoma. Furthermore, the controlled release of medications directly onto the eye from microfluidic contact lenses enhances therapeutic efficacy by increasing bioavailability. Despite current challenges such as scalable fabrication techniques, microfluidic contact lenses hold immense promise for ocular health, bridging the gap between diagnostics and treatment. This review summarizes the progress made in the design and fabrication of microfluidic contact lenses, with a special emphasis on the methods adopted to fabricate microfluidic contact lenses. Furthermore, the various applications of microfluidic contact lenses, ocular disease diagnosis, and drug delivery in particular are discussed in detail. Aside from outlining the state-of-the-art research activities in this area, challenges and future directions are discussed here.
- Open Access
- 19 October 2024
- Published by American Chemical Society (ACS) in ACS Applied Bio Materials
- Vol. 7 (11) , 7324-7331
Hydrogel-Embedded Polydimethylsiloxane Contact Lens for Ocular Drug Delivery
Topical administration is the commonly preferred method of administering ophthalmic formulations, with the majority of available medications in the form of eye drops or ointments. However, the topical application of ophthalmological medications has less bioavailability and a short residence time because of the physiological and anatomical constraints of the eye, making efficient ophthalmic drug delivery a challenging task. Microfluidic contact lenses have the advantage of delivering drugs into the eye in a controlled and on-demand manner. Here, we showcase the use of hydrogel-embedded microcavities on PDMS-based contact lenses for ocular drug delivery applications. The fabrication technique adopted here is the spontaneous formation of the spherical cavity by hydrogel monomer droplet, followed by the simultaneous thermal curing of hydrogel and PDMS, creating a spherical cavity as small as 150 μm. The spherical cavity is embedded with pH-responsive hydrogel for on-demand drug delivery. The drug loaded in the hydrogel matrix is released into the ocular environment by diffusion. The spherical cavity with a narrow opening restricts the diffusion to a minimum under normal ocular pH conditions(pH > 6). When the ocular pH reduces (pH < 6), the pH-responsive hydrogel inside the spherical cavity deswell and accelerates the drug release.
- 19 October 2024
- Published by American Chemical Society (ACS) in ACS Applied Bio Materials
- Vol. 7 (11) , 7324-7331
Open AccessHydrogel-Embedded Polydimethylsiloxane Contact Lens for Ocular Drug Delivery
Topical administration is the commonly preferred method of administering ophthalmic formulations, with the majority of available medications in the form of eye drops or ointments. However, the topical application of ophthalmological medications has less bioavailability and a short residence time because of the physiological and anatomical constraints of the eye, making efficient ophthalmic drug delivery a challenging task. Microfluidic contact lenses have the advantage of delivering drugs into the eye in a controlled and on-demand manner. Here, we showcase the use of hydrogel-embedded microcavities on PDMS-based contact lenses for ocular drug delivery applications. The fabrication technique adopted here is the spontaneous formation of the spherical cavity by hydrogel monomer droplet, followed by the simultaneous thermal curing of hydrogel and PDMS, creating a spherical cavity as small as 150 μm. The spherical cavity is embedded with pH-responsive hydrogel for on-demand drug delivery. The drug loaded in the hydrogel matrix is released into the ocular environment by diffusion. The spherical cavity with a narrow opening restricts the diffusion to a minimum under normal ocular pH conditions(pH > 6). When the ocular pH reduces (pH < 6), the pH-responsive hydrogel inside the spherical cavity deswell and accelerates the drug release.
- Open Access
- 22 March 2024
- Published by Royal Society of Chemistry (RSC) in Lab on a Chip
- Vol. 24 (8) , 2327-2334
A surface-engineered contact lens for tear fluid biomolecule sensing
Adhesive contrast contact lens fabricated by selective lubricant grafting splits tear film on specified zone by secretion and blinking. Integrating the contact lens with the spectroscopic technique offers an efficient platform for biomolecule sensing.
- 22 March 2024
- Published by Royal Society of Chemistry (RSC) in Lab on a Chip
- Vol. 24 (8) , 2327-2334
Open AccessA surface-engineered contact lens for tear fluid biomolecule sensing
Adhesive contrast contact lens fabricated by selective lubricant grafting splits tear film on specified zone by secretion and blinking. Integrating the contact lens with the spectroscopic technique offers an efficient platform for biomolecule sensing.