Latest Publications

  • Preparation and Testing of a Miniature High-Frequency Pulsed X-Ray Tube Based on Carbon Nanotube Cold Cathode

    by Kang Wang, Yunpeng Liu, Xiushan Wang, Menglai Tao, Xiaobin Tang

    In this study, a compact high-frequency pulsed X-ray tube based on carbon nanotube (CNT) field emission was developed. A high-adhesion CNT cathode electron emitter was fabricated using an optimized slurry method and a grooved metal substrate, resulting in improved emission stability. The cathode exhibited a turn-on field of 1.78 V/μm, a field enhancement factor of 6014, and current fluctuations of less than 4% after conditioning. A miniature X-ray tube prototype with a diameter of 15 mm and a height of 47 mm was built in a dynamic vacuum environment. The pulse characteristics, imaging performance, and X-ray communication capabilities are all evaluated. The prototype achieved an amplitude-frequency response bandwidth of 1.05 MHz at 3 dB. The imaging showed a minimum focal spot size of 0.879 mm × 1.153 mm, and high-speed imaging confirmed motion artifact suppression at pulse widths down to 300 μs. Reliable X-ray data transmission was demonstrated at data rates ranging from 1 to 6 Mbps, with PRBS7 encoding and bit error rates below 10⁻³. These results highlight the device’s potential for high-speed imaging, low-dose diagnostics, and X-ray communication.


  • Design and Testing of Metal Photocathode X-Ray Source Based on Microchannel Plate

    by Hao Yu, Yunpeng Liu, Xiushan Wang, Junxu Mu, Jiaxin Bai, Ao Xia, Kang Wang, Xiaobin Tang

    This work developed a microchannel plate-based metal photocathode X-ray source (MCP-MPXS). The MCP-MPXS structure was optimized using the non-dominated sorting genetic algorithm (NSGA)-II algorithm. A prototype was then built based on the optimization results, and the current characteristics, X-ray pulse properties, and X-ray imaging performance of the MCP-MPXS were investigated using a dynamic vacuum system. The MCP-MPXS achieved a current gain exceeding $10^{{4}}$ and had not yet reached its performance limit. With an X-ray pulse modulation frequency (MF) exceeding 10 MHz, the MCP-MPXS outperformed current grid-controlled modulated and most photocathode X-ray sources (PXSs). Modulation rates of several tens of megahertz can be achieved by refining the LED drive circuit. Furthermore, the MCP-MPXS obtained the best focal spot with a focusing ring voltage of 2000 V, which was consistent with the simulation results and verified the effectiveness of the optimization algorithm. The optimal focal spot is $0.53\times 0.79$ mm with an imaging resolution of up to 3.9 lp/mm. The system is also capable of dynamic imaging with X-ray pulse widths as short as $50~\mu $ s. Results show that the developed MCP-MPXS solves the problem of insufficient output intensity of traditional MPXSs, realizes high-speed X-ray modulation, and is capable of high-resolution X-ray imaging. This X-ray source has broad application prospects in X-ray communication and high-speed X-ray imaging.