CVCarolanne V. M. Vouriot

Carolanne V. M. Vouriot

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Carolanne V. M. Vouriot has a total of 4 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Uncertainties in exposure predictions arising from point measurements of carbon dioxide in classroom environments

    by Carolanne V. M. Vouriot, Maarten van Reeuwijk, Henry C. Burridge

    Predictions of airborne infection risk can be made based on the fraction of rebreathed air inferred from point measurements of carbon dioxide (CO ⁣ 2 ). We investigate the extent to which environmental factors, particularly spatial variations due to the ventilation provision, affect the uncertainty in these predictions. Spatial variations are expected to be especially problematic in naturally ventilated spaces, which include the majority of classrooms in the UK. An idealized classroom, broadly representative of the physics of (buoyancy-driven) displacement ventilation, is examined using computational fluid dynamics, with different ventilation configurations. Passive tracers are used to model both the CO ⁣ 2 generated by all 32 occupants and the breath of a single infectious individual (located in nine different regions). The distribution of infected breath is shown to depend strongly on the distance from the release location but is also affected by the pattern of the ventilating flow, including the presence of stagnating regions. However, far-field exposure predictions based on single point measurements of CO ⁣ 2 within the breathing zone are shown to rarely differ from the actual exposure to infected breath by more than a factor of two—we argue this uncertainty is small compared with other uncertainties inherent in modelling airborne infection risk.


  • Open Access

    Robustness of point measurements of carbon dioxide concentration for the inference of ventilation rates in a wintertime classroom

    by Carolanne V. M. Vouriot, Maarten van Reeuwijk, Henry C. Burridge

    Indoor air quality in schools and classrooms is paramount for the health and well-being of pupils and staff. CO2 monitors offer a cost-effective way to assess and manage ventilation provision. However, often only a single point measurement is available which might not be representative of the CO2 distribution within the room. A relatively generic UK classroom in wintertime is simulated using CFD. The natural ventilation provision is driven by buoyancy through high- and low-level openings in both an opposite-ended or single-ended configuration, in which only the horizontal location of the high-level vent is modified. CO2 is modelled as a passive scalar and is shown not to be `well-mixed' within the space. Perhaps surprisingly, the single-ended configuration leads to a `more efficient' ventilation, with lower average CO2 concentration. Measurements taken near the walls, often the location of CO2 monitors, are compared with those made throughout the classroom and found to be more representative of the ventilation rate if made above the breathing zone. These findings are robust with respect to ventilation flow rates and to the flow patterns observed, which were tested by varying the effective vent areas and the ratio of the vent areas.