Xiaoyu Qiu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Xiaoyu Qiu has a total of 10 co-authors. Here are the top co-authors by number of shared publications:
- Fengzhang Luo
State Key Laboratory of Smart Power Distribution Equipment and System, Tianjin University, Tianjin 300072, China
3 shared publications - Jiali Duan
State Grid Tianjin Electric Power Company, Tianjin 300010, China
2 shared publications - Zhe Wang
State Grid Tianjin Electric Power Company, Tianjin 300010, China
2 shared publications Fengzhang Luo
1 shared publication- Qingwei Wang
Shenzhen Power Supply Bureau Co., Ltd., Shenzhen 518048, China
1 shared publication - Shengyuan Wang1 shared publication
Latest Publications
- Top Cited PapersOpen Access
- 6 January 2026
- Published by Elsevier in International Journal of Electrical Power & Energy Systems
- Vol. 174
Long-term scenario generation for distribution network loads based on interpretable diffusion models
- 6 January 2026
- Published by Elsevier in International Journal of Electrical Power & Energy Systems
- Vol. 174
Top Cited PapersOpen AccessLong-term scenario generation for distribution network loads based on interpretable diffusion models
- Open Access
Optimal Configuration Model for Flexible Interconnected Distribution Transformer Areas Based on Load Aggregation
The large-scale integration of new power loads, such as electric vehicles and energy storage devices, has led to challenges including insufficient regulation capacity and low resource coordination efficiency in low-voltage distribution transformer areas. To address these issues, this paper proposes an optimal configuration model for flexible interconnected distribution transformer areas based on load aggregation. First, a flexible interconnection architecture is constructed using multi-port power electronic conversion devices, enabling mutual power support and voltage stabilization between adjacent areas. Second, a load aggregator scheduling model is established to quantitatively assess the dispatchable potential of electric vehicle charging loads. On this basis, a multi-objective optimization configuration model is formulated with the objectives of minimizing the comprehensive cost of the system and minimizing the average peak-valley difference of substation transformer loads. Case study results demonstrate that the proposed model significantly improves both economic efficiency and operational reliability. Compared to the traditional independent operation mode, the coordinated optimization scheme reduces the comprehensive system cost by 29.6% and narrows the average load peak-valley difference by 50.8%. These findings verify the synergistic effectiveness of flexible interconnection and load aggregation technologies in enhancing equipment utilization, reducing distribution losses, and improving power supply resilience.
Open AccessOptimal Configuration Model for Flexible Interconnected Distribution Transformer Areas Based on Load Aggregation
The large-scale integration of new power loads, such as electric vehicles and energy storage devices, has led to challenges including insufficient regulation capacity and low resource coordination efficiency in low-voltage distribution transformer areas. To address these issues, this paper proposes an optimal configuration model for flexible interconnected distribution transformer areas based on load aggregation. First, a flexible interconnection architecture is constructed using multi-port power electronic conversion devices, enabling mutual power support and voltage stabilization between adjacent areas. Second, a load aggregator scheduling model is established to quantitatively assess the dispatchable potential of electric vehicle charging loads. On this basis, a multi-objective optimization configuration model is formulated with the objectives of minimizing the comprehensive cost of the system and minimizing the average peak-valley difference of substation transformer loads. Case study results demonstrate that the proposed model significantly improves both economic efficiency and operational reliability. Compared to the traditional independent operation mode, the coordinated optimization scheme reduces the comprehensive system cost by 29.6% and narrows the average load peak-valley difference by 50.8%. These findings verify the synergistic effectiveness of flexible interconnection and load aggregation technologies in enhancing equipment utilization, reducing distribution losses, and improving power supply resilience.
- Open Access
Collaborative Forecasting of Multiple Energy Loads in Integrated Energy Systems Based on Feature Extraction and Deep Learning
Accurate load forecasting is crucial for the safe, stable, and economical operation of integrated energy systems. However, directly applying single models to predict coupled cooling, heating, and electric loads under complex influencing factors often yields unsatisfactory results. This paper proposes a collaborative load forecasting method based on feature extraction and deep learning. First, the complete ensemble empirical mode decomposition with adaptive noise algorithm decomposes load data, and a dynamic time warping-based k-medoids clustering algorithm reconstructs subsequences aligned with system load components. Second, a correlation analysis identifies the key influencing factors for model input. Then, a multi-task parallel learning framework combining a regression convolutional neural network and long short-term memory networks is developed to predict reconstructed subsequences. Case studies demonstrate that the proposed model achieves mean absolute percentage errors (MAPE) of 2.24%, 2.75%, and 1.69% for electricity, cooling, and heating loads on summer workdays, with mean accuracy (MA) values of 97.76%, 97.25%, and 98.31%, respectively. For winter workdays, the MAPE values are 2.92%, 1.66%, and 2.87%, with MA values of 97.08%, 98.34%, and 97.13%. Compared to traditional single-task models, the weighted mean accuracy (WMA) improves by 2.01% and 2.33% in summer and winter, respectively, validating its superiority. This method provides a high-precision tool for the planning and operation of integrated energy systems.
Open AccessCollaborative Forecasting of Multiple Energy Loads in Integrated Energy Systems Based on Feature Extraction and Deep Learning
Accurate load forecasting is crucial for the safe, stable, and economical operation of integrated energy systems. However, directly applying single models to predict coupled cooling, heating, and electric loads under complex influencing factors often yields unsatisfactory results. This paper proposes a collaborative load forecasting method based on feature extraction and deep learning. First, the complete ensemble empirical mode decomposition with adaptive noise algorithm decomposes load data, and a dynamic time warping-based k-medoids clustering algorithm reconstructs subsequences aligned with system load components. Second, a correlation analysis identifies the key influencing factors for model input. Then, a multi-task parallel learning framework combining a regression convolutional neural network and long short-term memory networks is developed to predict reconstructed subsequences. Case studies demonstrate that the proposed model achieves mean absolute percentage errors (MAPE) of 2.24%, 2.75%, and 1.69% for electricity, cooling, and heating loads on summer workdays, with mean accuracy (MA) values of 97.76%, 97.25%, and 98.31%, respectively. For winter workdays, the MAPE values are 2.92%, 1.66%, and 2.87%, with MA values of 97.08%, 98.34%, and 97.13%. Compared to traditional single-task models, the weighted mean accuracy (WMA) improves by 2.01% and 2.33% in summer and winter, respectively, validating its superiority. This method provides a high-precision tool for the planning and operation of integrated energy systems.
- Open Access
- 14 November 2024
- Published by MDPI AG in Applied Sciences
- Vol. 14 (22) , 10503
Optimal Configuration of Soft Open Point and Energy Storage Based on Snowflake-Shaped Grid Characteristics and Sensitivity Analysis
With the continuous penetration of flexible resources, the distribution network is gradually forming a two-way interactive supply and demand relationship with the transmission network and users. The deployment of soft open point (SOP) and energy storage represents a crucial strategy for voltage regulation and power flow control in distribution networks. This article puts forth a methodology for optimizing the configuration of SOP and energy storage based on the characteristics of the snowflake-shaped grid and sensitivity analysis. Firstly, the location of the SOP is determined based on the characteristics of the interconnection nodes between snowflake websites. Secondly, the voltage sensitivity analysis is employed to identify nodes that have a significant impact on the system voltage distribution, thereby enabling the selection of an optimal energy storage site. Subsequently, a multi-objective optimization configuration model for SOP and energy storage is established, taking into account the economic efficiency and load balancing of the power grid. Finally, the method is verified using a snowflake-shaped grid in Tianjin. In comparison with the plan that solely considers the economic aspects of the power grid, the method proposed in this article can reduce the degree of load balancing by 50.93% while simultaneously increasing the annual comprehensive cost by only 24.35%.
- 14 November 2024
- Published by MDPI AG in Applied Sciences
- Vol. 14 (22) , 10503
Open AccessOptimal Configuration of Soft Open Point and Energy Storage Based on Snowflake-Shaped Grid Characteristics and Sensitivity Analysis
With the continuous penetration of flexible resources, the distribution network is gradually forming a two-way interactive supply and demand relationship with the transmission network and users. The deployment of soft open point (SOP) and energy storage represents a crucial strategy for voltage regulation and power flow control in distribution networks. This article puts forth a methodology for optimizing the configuration of SOP and energy storage based on the characteristics of the snowflake-shaped grid and sensitivity analysis. Firstly, the location of the SOP is determined based on the characteristics of the interconnection nodes between snowflake websites. Secondly, the voltage sensitivity analysis is employed to identify nodes that have a significant impact on the system voltage distribution, thereby enabling the selection of an optimal energy storage site. Subsequently, a multi-objective optimization configuration model for SOP and energy storage is established, taking into account the economic efficiency and load balancing of the power grid. Finally, the method is verified using a snowflake-shaped grid in Tianjin. In comparison with the plan that solely considers the economic aspects of the power grid, the method proposed in this article can reduce the degree of load balancing by 50.93% while simultaneously increasing the annual comprehensive cost by only 24.35%.