RMRinat A. Miftakhov

Rinat A. Miftakhov

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Rinat A. Miftakhov has a total of 21 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Comparison of DNA Analysis on Biochips with Brush Polymer Cells and Cross-Linked Polymer Cells

    by R. A. Miftakhov, G. F. Shtylev, I. Yu. Shishkin, V. E. Shershov, V. E. Kuznetsova, S. A. Surzhikov, V. A. Vasiliskov, O. A. Zasedateleva, A. Yu. Ikonnikova, T. V. Nasedkina, et al.

    Objective: The regulation of substrate surface properties in biochip technology opens the possibility of optimizing platforms for efficient biomolecule recognition. The research aims to explore the potential of using brush polymers to improve the sensitivity and speed of DNA analysis on biochips. Methods: Brush polymer cells for biochips were prepared by UV-initiated polymerization of monomers from the surface on polyethylene terephthalate substrates. Cross-linked hydrogel polymer cells for biochips were prepared on polybutylene terephthalate substrates by copolymerization of gel components with DNA probes. The probes in brush polymer cells were immobilized through activated carboxyl groups. A 124 nucleotides long DNA target corresponding to the 7th exon of the human ABO gene was used for hybridization analysis. Hybridization of the target DNA was studied on biochips with cells made of brush polymers and cross-linked polyacrylamide hydrogels. The results were evaluated by digital fluorescence microscopy. Results and Discussion: Higher intensity of fluorescence signals and higher ratio of signals of cells with perfect duplexes to those of cells with imperfect duplexes were observed in cells made of brush polymers compared to cells made of three-dimensional cross-linked polymers. Achievement of hybridization signal up to 90% of saturation occurred at the same time in both cell types. Conclusions: Hybridization analysis on brush polymer cells in biochip technology showed increased sensitivity in detecting single nucleotide mutations.

  • Open Access

    Protein Biochips with Three-Dimensional Hydrogel or Polymer Brush Elements for the Detection of Human Serum Immunoglobulin E Specific to Inhalation Allergens

    by Rinat A. Miftakhov, Georgiy F. Shtylev, Daria A. Kachulyak, Ivan Yu. Shishkin, Vadim A. Vasiliskov, Veronika I. Butvilovskaya, Viktoriya E. Kuznetsova, Valeriy E. Shershov, Victor E. Barsky, Sergey A. Polyakov, et al.

    The development of rapid analysis of human serum for the presence of allergen-specific Immunoglobulin E (IgE) is currently important. Consequently, we developed two types of three-dimensional (3D) protein biochips. The first one is a 3D hydrogel biochip containing hydrogel droplets with protein molecules (allergens, immunoglobulins and others). These droplets are disposed on elements consisting of short polymer brushes grafting from a surface of polybutylene terephthalate polymer. The immobilization of proteins was induced by short-wave ultraviolet (UV) radiation. On such a biochip, the kinetics of allergen–sIgE complex formation reached 60% of saturation for 6 h. Also, we developed a 3D brush microchip containing on the surface of a polyethylene terephthalate polymer the brush elements with protein molecules covalently immobilized by opening oxirane cycles by amino and thiol nucleophilic groups contained in proteins. In the case of the 3D brush microchip, the kinetics of allergen–sIgE complex formation reached 100% of saturation for 3 h, and fluorescent signals were 2–3 times higher than those of the 3D hydrogel biochip for some allergens. Thus, the comparative analysis revealed that 3D brush biochips are more useful for further studies of protein–protein interaction than 3D hydrogel ones.


  • Open Access

    Protein Biochips with Three-Dimensional Hydrogel or Polymer Brush Elements for the Detection of Human Serum IgE Specific to Inhalation Allergens

    by Rinat A. Miftakhov, Georgiy F. Shtylev, Daria A. Kachulyak, Ivan Yu. Shishkin, Vadim A. Vasiliskov, Veronika I. Butvilovskaya, Viktoriya E. Kuznetsova, Valeriy E. Shershov, Victor E. Barsky, Sergey A. Polyakov, et al.

    The development of rapid analysis of human serum for the presence of allergen-specific IgE is currently important. Consequently, we developed two types of 3D protein biochips. The first one is a 3D hydrogel biochip containing hydrogel droplets with protein molecules (allergens, immunoglobulins and others). These droplets are disposed on elements consisting of short polymer brushes grafting from a surface of polybutylene terephthalate polymer. The immobilization of proteins was induced by short-wave UV radiation. On such a biochip, the kinetics of allergen-sIgE complex formation reached 70% of saturation for 6 hours. Also we developed a 3D brush microchip containing on the surface of a polyethylene terephthalate polymer the brush elements with protein molecules covalently immobilized by opening oxirane cycles by amino and thiol nucleophilic groups contained in proteins. In the case of 3D brush microchip the kinetics of allergen-sIgE complex formation reached 100% of saturation for 3 hours, and fluorescent signals were 2-3 times higher than those of the 3D hydrogel biochip. Thus, the comparative analysis revealed that 3D brush biochips are more useful for further studies of protein-protein interactions than 3D hydrogel ones.