Luisa de Roy
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Luisa de Roy has a total of 14 co-authors. Here are the top co-authors by number of shared publications:
Andreas Martin Seitz
Institute of Orthopaedic Research and Biomechanics, Centre of Trauma Research Ulm, Ulm University Medical Center, Ulm, Germany
2 shared publications- Andreas Martin Seitz
Institute of Orthopedic Research and Biomechanics, Center for Trauma Research, Ulm University Medical Center Ulm, Germany
2 shared publications Anita Ignatius
Institute of Orthopaedic Research and Biomechanics, Centre of Trauma Research Ulm, Ulm University Medical Center, Ulm, Germany
2 shared publications- Anita Ignatius
Institute of Orthopedic Research and Biomechanics, Ulm University Medical Center, Germany
2 shared publications - Martin Faschingbauer
Department of Orthopedic Surgery, RKU, Ulm University Medical Center, Ulm, Germany
2 shared publications Graciosa Quelhas Teixeira
Institute of Orthopaedic Research and Biomechanics, Centre of Trauma Research Ulm, Ulm University Medical Center, Ulm, Germany
1 shared publication
Latest Publications
- 29 September 2025
- Published by British Editorial Society of Bone & Joint Surgery in Orthopaedic Proceedings
- Vol. 107-B (SUPP_8) , 14
SYNOVIAL FLUID ALTERATIONS CONTRIBUTE TO TRIBOLOGICAL IMBALANCES IN OSTEOARTHRITIC CARTILAGE
Low friction in the knee joint arises from an interplay between articular cartilage (AC) and synovial fluid (SF). In osteoarthritis (OA), AC degradation and changes in SF composition alter this tribological interface. However, the specific impact of OA-related SF changes on AC friction under physiological loading is not fully understood. Therefore, the aim of this study was to investigate patient-specific correlations between SF composition, viscosity, and cartilage friction coefficients to identify key SF alterations contributing to increased friction as a potential risk factor for OA progression.Following IRB approval, SF samples and tibial plateaus were collected from 12 patients undergoing knee arthroplasty (age 75 ± 8 years; KL score: 3–4). SF samples were centrifuged and analyzed for biochemical properties and viscosity. Cylindrical cartilage samples (Ø 5mm) were extracted for friction tests in a cartilage-against-glass configuration using 0.1 ml patient-specific SF as lubricant. Simulated gait loading was applied, and friction coefficients (µ) were calculated at different gait phases and time points. Cartilage structure was assessed via thickness (h0) and ICRS score. Hyaluronic acid (HAC), lubricin (PRG4), and total protein concentration (TPC) were analyzed biochemically. SF viscosity was measured using a rheometer. Spearman correlation coefficients (ρ) were calculated to evaluate relationships among variables, with p < 0.05 considered significant.Strong negative correlations were observed between PRG4 concentration and µendGait, µendStance, and µendSwing Moderate correlations showed that µ0Stance was negatively associated with HAC, but positively associated with µendGait and µendStance. TPC showed moderate negative correlations with µ0 values. SF viscosity correlated negatively with µ0, except for η0.01 at 25°C. HAC strongly correlated with ICRS score and h0. Moderate negative correlations were found between SF viscosity and cartilage structure.The results confirm PRG4 as a critical boundary lubricant, with lower concentrations associated with higher friction, particularly after prolonged testing]. Reduced PRG4 and low SF viscosity impair lubrication, leading to higher friction which might promote OA progression. High TPC may disrupt lubrication layer formation by competing with other molecules. SF changes contribute to altered cartilage friction and may be risk factors for OA progression. These findings highlight the need for injectable tribo-supplements to restore SF composition and reduce joint friction, thereby advancing OA treatment.
- 29 September 2025
- Published by British Editorial Society of Bone & Joint Surgery in Orthopaedic Proceedings
- Vol. 107-B (SUPP_8) , 14
SYNOVIAL FLUID ALTERATIONS CONTRIBUTE TO TRIBOLOGICAL IMBALANCES IN OSTEOARTHRITIC CARTILAGE
Low friction in the knee joint arises from an interplay between articular cartilage (AC) and synovial fluid (SF). In osteoarthritis (OA), AC degradation and changes in SF composition alter this tribological interface. However, the specific impact of OA-related SF changes on AC friction under physiological loading is not fully understood. Therefore, the aim of this study was to investigate patient-specific correlations between SF composition, viscosity, and cartilage friction coefficients to identify key SF alterations contributing to increased friction as a potential risk factor for OA progression.Following IRB approval, SF samples and tibial plateaus were collected from 12 patients undergoing knee arthroplasty (age 75 ± 8 years; KL score: 3–4). SF samples were centrifuged and analyzed for biochemical properties and viscosity. Cylindrical cartilage samples (Ø 5mm) were extracted for friction tests in a cartilage-against-glass configuration using 0.1 ml patient-specific SF as lubricant. Simulated gait loading was applied, and friction coefficients (µ) were calculated at different gait phases and time points. Cartilage structure was assessed via thickness (h0) and ICRS score. Hyaluronic acid (HAC), lubricin (PRG4), and total protein concentration (TPC) were analyzed biochemically. SF viscosity was measured using a rheometer. Spearman correlation coefficients (ρ) were calculated to evaluate relationships among variables, with p < 0.05 considered significant.Strong negative correlations were observed between PRG4 concentration and µendGait, µendStance, and µendSwing Moderate correlations showed that µ0Stance was negatively associated with HAC, but positively associated with µendGait and µendStance. TPC showed moderate negative correlations with µ0 values. SF viscosity correlated negatively with µ0, except for η0.01 at 25°C. HAC strongly correlated with ICRS score and h0. Moderate negative correlations were found between SF viscosity and cartilage structure.The results confirm PRG4 as a critical boundary lubricant, with lower concentrations associated with higher friction, particularly after prolonged testing]. Reduced PRG4 and low SF viscosity impair lubrication, leading to higher friction which might promote OA progression. High TPC may disrupt lubrication layer formation by competing with other molecules. SF changes contribute to altered cartilage friction and may be risk factors for OA progression. These findings highlight the need for injectable tribo-supplements to restore SF composition and reduce joint friction, thereby advancing OA treatment.
- 8 September 2025
- Published by British Editorial Society of Bone & Joint Surgery in Orthopaedic Proceedings
- Vol. 107-B (SUPP_6) , 53
A ROBOTIC TEST SETUP FOR BIOTRIBOLOGICAL INVESTIGATIONS ON COMPLEX SHAPED CARTILAGE SURFACES
Investigating the frictional properties of the articular cartilage (AC) contributes to the understanding of the knee joint's overall functionality [1]. However, a key challenge in tribological studies remains addressing the complex geometry of the tibial and femoral AC surfaces. Therefore, the aim of this study was to develop a robotic based tribological setup that allows for friction measurements on curved AC surfaces, without disrupting its structural integrity, under orthogonal contact conditions and controlled normal force application.A six-axis industrial robot was programmed to move a pin along trajectories orthogonal to a surface. First, for system validation the friction coefficients (µ=friction force/normal force) of polyoxymethylene (POM) pins on three different polyamide (PA) shapes were determined (Figure 1A). Second, the friction coefficients on six medial porcine tibial surfaces were assessed (Figure 1B). On each plateau, three trajectories were tested in intact conditions and after inducing an anteromedial defect with sandpaper on two trajectories. Phosphate-buffered saline was used as lubricant. In all tests, a normal force of 5 N and a sliding velocity of 1 mm/s was applied. Parametric statistical tests were used for data comparison with p<0.05 considered statistically significant.Friedman testing revealed no significant differences in the friction coefficients µ across the PA shapes (Figure 2A). Introducing an anteromedial AC defect significantly increased friction on the affected trajectories (µ +30%, t-testing: p < 0.05) The visualization of local friction coefficients along the trajectory demonstrated that the overall higher friction was attributable to higher µ values in the defect regionThe robotic tribometer was successfully validated, as the friction coefficients of the PA shapes showed no significant differences despite varying shape complexities. The robotic tribometer effectively measured friction on curved porcine tibial AC surfaces while maintaining the tissue integrity. Moreover, it was possible to detect localized friction changes caused by local structural damage. This methodological opportunity is particularly relevant for OA research, as localized AC damage is a defining characteristic of the disease [2]. Overall, the robotic tribometer offers a novel method for investigating the AC's frictional behaviour, which has the potential to enhance our understanding of the tissue's tribology in healthy and diseased conditions.For any figures or tables, please contact the authors directly.
- 8 September 2025
- Published by British Editorial Society of Bone & Joint Surgery in Orthopaedic Proceedings
- Vol. 107-B (SUPP_6) , 53
A ROBOTIC TEST SETUP FOR BIOTRIBOLOGICAL INVESTIGATIONS ON COMPLEX SHAPED CARTILAGE SURFACES
Investigating the frictional properties of the articular cartilage (AC) contributes to the understanding of the knee joint's overall functionality [1]. However, a key challenge in tribological studies remains addressing the complex geometry of the tibial and femoral AC surfaces. Therefore, the aim of this study was to develop a robotic based tribological setup that allows for friction measurements on curved AC surfaces, without disrupting its structural integrity, under orthogonal contact conditions and controlled normal force application.A six-axis industrial robot was programmed to move a pin along trajectories orthogonal to a surface. First, for system validation the friction coefficients (µ=friction force/normal force) of polyoxymethylene (POM) pins on three different polyamide (PA) shapes were determined (Figure 1A). Second, the friction coefficients on six medial porcine tibial surfaces were assessed (Figure 1B). On each plateau, three trajectories were tested in intact conditions and after inducing an anteromedial defect with sandpaper on two trajectories. Phosphate-buffered saline was used as lubricant. In all tests, a normal force of 5 N and a sliding velocity of 1 mm/s was applied. Parametric statistical tests were used for data comparison with p<0.05 considered statistically significant.Friedman testing revealed no significant differences in the friction coefficients µ across the PA shapes (Figure 2A). Introducing an anteromedial AC defect significantly increased friction on the affected trajectories (µ +30%, t-testing: p < 0.05) The visualization of local friction coefficients along the trajectory demonstrated that the overall higher friction was attributable to higher µ values in the defect regionThe robotic tribometer was successfully validated, as the friction coefficients of the PA shapes showed no significant differences despite varying shape complexities. The robotic tribometer effectively measured friction on curved porcine tibial AC surfaces while maintaining the tissue integrity. Moreover, it was possible to detect localized friction changes caused by local structural damage. This methodological opportunity is particularly relevant for OA research, as localized AC damage is a defining characteristic of the disease [2]. Overall, the robotic tribometer offers a novel method for investigating the AC's frictional behaviour, which has the potential to enhance our understanding of the tissue's tribology in healthy and diseased conditions.For any figures or tables, please contact the authors directly.
- Open Access
- 18 January 2025
- Published by Elsevier in Osteoarthritis and Cartilage Open
- Vol. 7 (1) , 100568
Friction of osteoarthritic cartilage with patient-specific synovial fluid: Effect of different loading conditions
- 18 January 2025
- Published by Elsevier in Osteoarthritis and Cartilage Open
- Vol. 7 (1) , 100568
Open AccessFriction of osteoarthritic cartilage with patient-specific synovial fluid: Effect of different loading conditions
- Open Access
- 18 October 2024
- Published by Elsevier in Acta Biomaterialia
- Vol. 190, 293-302
Structure-function of cartilage in osteoarthritis: An ex-vivo correlation analysis between its structural, viscoelastic and frictional properties
- 18 October 2024
- Published by Elsevier in Acta Biomaterialia
- Vol. 190, 293-302
Open AccessStructure-function of cartilage in osteoarthritis: An ex-vivo correlation analysis between its structural, viscoelastic and frictional properties