Rong Chen
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Rong Chen has a total of 6 co-authors. Here are the top co-authors by number of shared publications:
- Chengjun Wang
School of Computer Science, Xiangtan University, Xiangtan, China
1 shared publication - Lijing Bu
School of Automation and Electronic Information, Xiangtan University, Xiangtan, China
1 shared publication - Mingjun Deng
School of Automation and Electronic Information, Xiangtan University, Xiangtan 411105, China
1 shared publication - Yin Yang
National Center for Applied Mathematics in Hunan, Hunan International Scientific and Technological Innovation Cooperation Base of Computational Science, School of Mathematics and Computational Science, Xiangtan University, Xiangtan, China
1 shared publication - Zhengpeng Zhang
Xiangtan University
1 shared publication - Zhiyuan Chen
School of Automation and Electronic Information, Xiangtan University, Xiangtan, China
1 shared publication
Latest Publications
- 30 October 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Geoscience and Remote Sensing
- Vol. 62 (01962892) , 1-11
Spaceborne SAR Radiometric Cross-Calibration Considering Typical Scattering Effects in Building Areas
With the increasing number of spaceborne SAR systems, traditional absolute radiometric calibration methods based on calibration fields are becoming increasingly difficult to meet the demand for long-term monitoring of radiometric accuracy in spaceborne SAR images. SAR radiometric cross calibration methods based on the stability characteristics of big data are expected to solve this problem. In this study, a space-borne SAR radiometric cross calibration method considering typical scattering effects in building areas was proposed by analyzing the imaging mechanism of SAR images of building areas. The experiment using Sentinel-1A/1B data has verified that extracting stable pixels based on this method can effectively improve the stability of the calibration benchmark, and it has been determined that mean centroid of building areas based on the sliding window is a more stable calibration benchmark. The stability of this calibration benchmark is 0.23dB, which is more stable than that of tropical rainforests; In addition, a SAR radiometric cross calibration scheme was designed, and experiments were conducted based on this scheme. The experimental results showed that the absolute calibration accuracy of cross calibration on the same satellite was 0.25dB, and that of cross calibration on different satellites was 0.36dB.
- 30 October 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Geoscience and Remote Sensing
- Vol. 62 (01962892) , 1-11
Spaceborne SAR Radiometric Cross-Calibration Considering Typical Scattering Effects in Building Areas
With the increasing number of spaceborne SAR systems, traditional absolute radiometric calibration methods based on calibration fields are becoming increasingly difficult to meet the demand for long-term monitoring of radiometric accuracy in spaceborne SAR images. SAR radiometric cross calibration methods based on the stability characteristics of big data are expected to solve this problem. In this study, a space-borne SAR radiometric cross calibration method considering typical scattering effects in building areas was proposed by analyzing the imaging mechanism of SAR images of building areas. The experiment using Sentinel-1A/1B data has verified that extracting stable pixels based on this method can effectively improve the stability of the calibration benchmark, and it has been determined that mean centroid of building areas based on the sliding window is a more stable calibration benchmark. The stability of this calibration benchmark is 0.23dB, which is more stable than that of tropical rainforests; In addition, a SAR radiometric cross calibration scheme was designed, and experiments were conducted based on this scheme. The experimental results showed that the absolute calibration accuracy of cross calibration on the same satellite was 0.25dB, and that of cross calibration on different satellites was 0.36dB.