Alex Lua
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Alex Lua has a total of 11 co-authors. Here are the top co-authors by number of shared publications:
- Alba Sierra
Department of Urology, Hospital Clinic-University of Barcelona, Barcelona, Spain
1 shared publication - Catalina Solano
Groupe de Recherche Clinique sur la Lithiase Urinaire, GRC n°20, Hôpital Tenon, Sorbonne Université, Paris, France
1 shared publication - Etienne Xavier Keller
Department of Urology, University Hospital Zürich, University of Zürich, Zürich, Switzerland
1 shared publication - Eugenio Ventimiglia
Department of Surgical Sciences Uppsala University Uppsala Sweden
1 shared publication - Frédéric Panthier
Service d’Urologie, Assistance-Publique Hôpitaux de Paris, Hôpital Tenon, Sorbonne Université, Paris, France
1 shared publication - Jia-Lun Kwok
Tan Tock Seng Hospital
1 shared publication
Latest Publications
- 30 October 2024
- Published by Springer Nature in World Journal of Urology
- Vol. 42 (1) , 1-10
Optimal deflection techniques for flexible and navigable suction ureteral access sheaths (FANS): a comparative in vitro PEARLS analysis
Purpose Flexible and navigable suction ureteral access sheaths (FANS) have been introduced without current evidence on how to optimize deflection. Aim was to evaluate in vitro deflection angles with 2 different FANS techniques–sheath advancement and ureteroscope deflection; and effects of sheath size-ureteroscope combinations. Methods We evaluated in vitro deflection angles of 10/12Fr, 11/13Fr and 12/14Fr FANS (Hunan Reborn Medical Co. Ltd) with six single-use flexible ureteroscopes (Pusen Uscope 7.5Fr, OTU WiScope 7.5Fr, OTU WiScope 8.6Fr, Innovex EU-scope 8.7Fr, Red Pine RP-U-C12 8.7Fr and Boston Scientific Lithovue 9.5Fr). Two deflection techniques were tested: (1) sheath advancement—advancing the sheath forward over a maximally deflected ureteroscope, and (2) ureteroscope deflection—maximally deflecting the ureteroscope from various starting positions relative to tip of the sheath. Results Intra and inter-scope comparisons of maximum deflection angles were significantly different (all ANOVA p < 0.01). Largest maximum angles for all ureteroscopes were with the sheath advancement technique (range 218°–277°), and second largest for most scopes using the ureteroscope deflection technique at tip (range 111°–212°), mostly deviating from manufacturer specifications (range 270°–275°). 10/12Fr and 11/13Fr sheath sizes were more flexible than 12/14Fr. Largest angles were with 11/13Fr sheath–OTU8.6Fr/Innovex8.7Fr combinations. Conclusion Optimal deflection with FANS is achieved using either a sheath advancement technique, or ureteroscope deflection technique at tip. Despite using these optimized techniques, deflection angles specified by manufacturers seem hardly achievable. The sheath advancement technique and 11/13Fr sheath–OTU8.6Fr/Innovex8.7Fr combinations may be better suited for lower pole situations. Urologists should be aware of these differences and apply the findings to their FANS technique.
- 30 October 2024
- Published by Springer Nature in World Journal of Urology
- Vol. 42 (1) , 1-10
Optimal deflection techniques for flexible and navigable suction ureteral access sheaths (FANS): a comparative in vitro PEARLS analysis
Purpose Flexible and navigable suction ureteral access sheaths (FANS) have been introduced without current evidence on how to optimize deflection. Aim was to evaluate in vitro deflection angles with 2 different FANS techniques–sheath advancement and ureteroscope deflection; and effects of sheath size-ureteroscope combinations. Methods We evaluated in vitro deflection angles of 10/12Fr, 11/13Fr and 12/14Fr FANS (Hunan Reborn Medical Co. Ltd) with six single-use flexible ureteroscopes (Pusen Uscope 7.5Fr, OTU WiScope 7.5Fr, OTU WiScope 8.6Fr, Innovex EU-scope 8.7Fr, Red Pine RP-U-C12 8.7Fr and Boston Scientific Lithovue 9.5Fr). Two deflection techniques were tested: (1) sheath advancement—advancing the sheath forward over a maximally deflected ureteroscope, and (2) ureteroscope deflection—maximally deflecting the ureteroscope from various starting positions relative to tip of the sheath. Results Intra and inter-scope comparisons of maximum deflection angles were significantly different (all ANOVA p < 0.01). Largest maximum angles for all ureteroscopes were with the sheath advancement technique (range 218°–277°), and second largest for most scopes using the ureteroscope deflection technique at tip (range 111°–212°), mostly deviating from manufacturer specifications (range 270°–275°). 10/12Fr and 11/13Fr sheath sizes were more flexible than 12/14Fr. Largest angles were with 11/13Fr sheath–OTU8.6Fr/Innovex8.7Fr combinations. Conclusion Optimal deflection with FANS is achieved using either a sheath advancement technique, or ureteroscope deflection technique at tip. Despite using these optimized techniques, deflection angles specified by manufacturers seem hardly achievable. The sheath advancement technique and 11/13Fr sheath–OTU8.6Fr/Innovex8.7Fr combinations may be better suited for lower pole situations. Urologists should be aware of these differences and apply the findings to their FANS technique.