XZXinyi Zhu

Xinyi Zhu

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Xinyi Zhu has a total of 13 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    A Complementary Approach for Characterizing Dark Count Rate in First-Photon-Gated Single-Photon Detectors

    by Hanping Zhang, Xinyi Zhu, Yurong Wang, E Wu, Guang Wu

    In single-photon detection, dark count represents a critical limitation, particularly for high-sensitivity applications. Conventional estimators based on the binary per-gate observable become ill-conditioned when the dark count per-gate probability approaches unity, a situation common in first-photon-gated detectors with extended gate width. This work proposes a complementary characterization method based on the statistical expectation of dark count arrival time. This approach captures the cumulative temporal behavior of dark count across multiple gating cycles, providing a more accurate estimation of the dark count rate. Both numerical simulations and experimental results demonstrate that our method yields significantly more stable and precise measurements compared to the conventional approach. Specifically, while the conventional method introduces errors up to ±4% at larger gate widths, the proposed timing-based method converges to a significantly lower residual error of approximately −0.17%. These findings offer a promising route to enhance the characterization and performance of first-photon-gated single-photon detectors in practical applications.


  • Unknown weak light pulse measurement using time interval distribution photon counting

    by Xinyi Zhu, Yurong Wang, Xue Li, Zhaohui Li, Haifeng Pan, Xiuliang Chen, Pengcheng Zhang, Kun Huang, Guang Wu

    In this paper, we present a method for measuring weak light pulses using a single-photon detector, with a focus on detecting non-synchronized repetitive pulsed light. The proposed approach, based on interval distribution counting, enables accurate reconstruction of both the repetition rate and phase of weak pulses, facilitating the determination of the average photon number and pulse width. Specifically, the error in reconstructing the repetition rate is below ±0.01%, while the error in measuring the photon number per pulse remains below ±0.8%.


  • Open Access

    Two-Way Single-Photon Laser Time Transfer for High-Speed Moving Platforms

    by Xinyi Zhu, Yurong Wang, Zhaohui Li, Xue Li, Guang Wu

    The two-way laser time transfer technology, based on single-photon detection, is among the techniques requiring the least weight and power consumption for ultra-long-distance clock synchronization. It holds promise as the most viable technology for high-accuracy inter-satellite clock synchronization, particularly for small satellites that are highly sensitive to weight and power consumption. In this study, we analyze laser time transfer in fast-moving platforms and find that not only does the relative motion speed between platforms significantly impact the clock offset measurement, but also the components of each platform’s relative motion velocity are critical. We introduce a lightweight scenario for laser time transfer, capable of achieving high-precision and high-accuracy interstellar clock offset measurements within a 5000 km range using high repetition rate microchip lasers and single-pixel single-photon detectors. With a speed accuracy of ±0.06 m/s, the precision of clock offset measurement surpasses 3 ps at full width at half maximum (FWHM), making it suitable for high-speed and high-precision clock synchronization between near-Earth satellites.