RZRaihanita Zahra

Raihanita Zahra

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Raihanita Zahra has a total of 17 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Efficacy of Intranasal Dexmedetomidine Premedication as an Adjunct on Intubation Process in Paediatric Patients: A Randomized, Double-blind, Placebo-controlled Trial

    by Octava Prima Arta, Raihanita Zahra, Christopher Kapuangan, Indro Mulyono, Arif H. M. Marsaban, Aldy Heriwardito

    Efficacy of Intranasal Dexmedetomidine Premedication as an Adjunct on Intubation Process in Paediatric Patients: A Randomized, Double-blind, Placebo-controlled Trial - Turkish Journal of Anaesthesiology and Reanimation

  • Open Access

    Influencing factors of patient safety in anesthesia services in a low- and middle-income country

    by Aldy Heriwardito, Andi Ade Wijaya Ramlan, Raihanita Zahra, Amelia Martira, Bintang Pramodana, Agung Bintartho, Raden Besthadi Sukmono, Joshua Eldad Frederich Lasanudin

    Patient safety in anesthesia remains a concern in low- and middle-income countries due to workforce shortages, limited equipment, and inconsistent protocols. In Jakarta, where demand for anesthesia is rising, baseline data on these parameters are lacking. This study aimed to identify gaps in human resources, equipment availability, and safety protocol adherence. A cross-sectional survey of all actively practicing anesthesiologists in Jakarta was conducted in January 2024, yielding 115 responses. The questionnaire, developed and face-validated through a focus group with senior anesthesiologists, covered three domains: human resources, facilities and equipment, and protocols. Internal reliability was assessed using Cronbach’s alpha. Participation was voluntary, responses were anonymous, and data were analyzed using descriptive statistics. Prolonged work hours were reported by a minority of respondents (6.1-7%), with 22.7% agreeing that anesthesiologists' workload is too high. Most rated human resource parameters positively (median 4/5), but access to basic monitoring devices for oxygenation, ventilation, circulation, and temperature was limited. Protocol adherence was generally high (median 4-5/5), though a small minority of institutions lacked incident reporting pathways, patient risk assessment, and post-surgical recovery rooms. Improving patient safety in Jakarta requires ensuring essential monitoring equipment, optimizing staffing to manage workload, and mandating full perioperative safety protocols across facilities.

  • Open Access

    Colorado Pediatric Airway Score (COPUR) as a Predictor of Intubation Difficulty in Children Aged 1-8 Years

    by Christopher Kapuangan, Aries Perdana, Fulki Fadhila, Andi Ade Wijaya Ramlan, Raihanita Zahra, Komang Ayu Ferdiana, Rahendra Rahendra

    Background: Airway management is critical in pediatric anesthesia, as failure can lead to severe complications, including cardiac arrest. Anticipating and preparing for difficult intubation is essential, particularly in children with unique anatomical and physiological characteristics. The Colorado Pediatric Airway Score (COPUR) is a predictive tool for assessing intubation difficulty in pediatric patients.Objective: This study evaluates the validity of COPUR in predicting difficult intubation in children.Methods: A cross-sectional diagnostic study was conducted on 121 pediatric patients (aged 1–8 years) undergoing general anesthesia at Cipto Mangunkusumo Hospital. COPUR assesses jaw structure, mouth opening, prior intubation history, uvula visibility, neck movement, and additional modifying factors (macroglossia, obesity, mucopolysaccharidosis, and protruding teeth). A COPUR score >7 was used to predict difficult intubation, while intubation difficulty was defined by an Intubation Difficulty Score (IDS) >5.Results: A COPUR score ≥8 predicted difficult intubation in 15.7% of patients, whereas actual difficult intubation occurred in 9.92%. A COPUR threshold of ≥7 provided optimal sensitivity (83.3%) and specificity (61.47%), outperforming the original cutoff of 8 (50% sensitivity, 87% specificity). The score demonstrated good discriminative ability (AUC-ROC: 0.770, 95% CI: 0.685–0.842) and suitable calibration (Hosmer-Lemeshow test, p = 0.584).Conclusion: The COPUR score is a valid tool for predicting difficult intubation in pediatric patients aged 1–8 years, demonstrating fairly good discrimination and calibration values.

  • Open Access

    Endotracheal intubation using a spiral endotracheal tube effectively reduces total tube handling time in children aged one month to six years using a McGrathTM video laryngoscope: a prospective randomized trial

    by Rahendra Rahendra, Fajar Sesario, Andi Ade Wijaya Ramlan, Raihanita Zahra, Christopher Kapuangan, Arif Hari Martono Marsaban, Aries Perdana

    Background: Airway management in the pediatric population is challenging because of the smaller size, different proportions of anatomical structures compared to adults, and a higher risk of hypoxemia. Efforts to improve the efficiency of pediatric intubation can be made by manually twisting a spiral endotracheal tube (ETT) using a flexible stylet to manipulate its shape and angle. Methods: This controlled trial randomized and assigned fifty children aged one month to six years who underwent elective surgery under general anesthesia into two groups (spiral ETT [sETT] and no-stylet ETT/standard ETT). The sETT was formed by twisting the ETT using a handmade tool. The primary objective of this study was to determine the effectiveness of the sETT compared to the standard ETT in reducing intubation time. Secondary objectives were ETT placement accuracy, first-attempt intubation success rate, and adverse effects.Results: The mean total tube handling time in the sETT group was significantly shorter compared to the no stylet ETT group (sETT 16.8 ± 3.6 vs. standard ETT 18.8 ± 3.7 seconds; t = 2.0; P = 0.049). sETT placement had a significantly greater central placement accuracy (odds ratio, 4.846; 95% confidence interval, 1.287-18.255; P = 0.015). However, first-attempt successful intubation rate (sETT 80% vs. standard ETT 64%, P = 0.208) and total intubation time (sETT: 46.5±5.2 vs. standard ETT 48.4±4.9 seconds; t = 1.3; P = 0.205) were not significantly different. No adverse effects were observed for either ETT type.Conclusions: This study demonstrated the effectiveness of the spiral ETT in reducing total tube handling time and improving ETT placement accuracy in children using video laryngoscopy.


  • Open Access

    Perioperative Fluid Management in Paediatric Liver Transplantation: A Systematic Review

    by Raihanita Zahra, Andi Ade Wijaya Ramlan, Christopher Kapuangan, Rahendra Rahendra, Komang Ayu Ferdiana, Arif Hari Martono Marsaban, Aries Perdana, Nathasha Brigitta Selene

    Perioperative Fluid Management in Paediatric Liver Transplantation: A Systematic Review - Turkish Journal of Anaesthesiology and Reanimation