Cherry Kit-Fong Hin
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Cherry Kit-Fong Hin has a total of 8 co-authors. Here are the top co-authors by number of shared publications:
- Anuprita Kanitkar
Department of Physical Therapy, College of Rehabilitation Sciences, University of Manitoba, Winnipeg, MB, Canada
4 shared publications - Nariman Sepehri
Department of Mechanical Engineering, University of Manitoba, Winnipeg, Manitoba R3T 5V6, Canada
4 shared publications - Sanjay Tejraj Parmar
SDM College of Physiotherapy, Shree Dharmasthala Manjunatheshwara University, Dharwad 580009, Karnataka, India
4 shared publications - Tony Szturm
College of Rehabilitation Sciences, Rady Faculty of Health Sciences, University of Manitoba, Winnipeg, MB, Canada
4 shared publications - Mrudula Kanakapura Peramalaiah
SDM College of Physiotherapy, Shri Dharmasthala Manjunatheshwara University, Dharwad, India
2 shared publications - Saman Muthukumarana
Department of Statistics, University of Manitoba, Winnipeg, Canada
2 shared publications
Latest Publications
- Open Access
- 19 March 2025
- Published by JMIR Publications Inc. in JMIR Neurotechnology
- Vol. 4, e67779
A Game-Based Mechatronic Device for Digital Rehabilitation of Hand Function After a Stroke: Design, Prototyping, and Feasibility Study
Background: This paper presents an easy-to-use, affordable robotic manipulandum device (RMD) equipped with smart monitoring and assistive technologies to engage in game-based exercise and repetitive task practice. The RMD has been designed to enhance a wide range of fine motor manual dexterity skills, including thumb, finger, and wrist movements. By focusing on finger and hand functions, it extends its utility beyond basic reaching or object transfer movements. Various interchangeable 3D-printed therapy handles of different shapes and sizes can be easily attached to the RMD drive shaft. These handle movements can be used to engage with numerous affordable, commercially available computer games, allowing patients to practice tasks that involve varying movement amplitudes, speeds, precision, and cognitive challenges. Additionally, the device is capable of automatically recording and storing the patient’s real-time performance data on any given computer, integrating assessment into treatment. Objective: A pilot study was conducted with 5 patients with stroke to examine the feasibility and benefits of a 6-week game-based exercise program using the proposed device. Methods: A feasibility study was conducted with 5 participants. Data were collected using the computer game–based upper extremity assessment of manual dexterity and Wolf Motor Function Test (WMFT) before and after the intervention lasting 6 weeks. Results: The pilot study demonstrated that clients’ expectations related to manual dexterity were met. The average improvement in the functional ability score of the WMFT was 14 (SD 3) points, with all participants exceeding the minimal clinically important difference. The average reduction in total time was 30 (SD 14) seconds, with 4 of 5 participants surpassing the minimal clinically important difference. For the computer game–based upper extremity assessment, the average improvement in success rate was 23% (SD 12%), and the average decrease in response time was 105 (SD 44) milliseconds. Conclusions: Findings revealed acceptable, engaging, game-based, and task-oriented training with a high level of compliance. Substantial improvements from pre- to postintervention were observed using the WMFT and assessments of manual dexterity.
- 19 March 2025
- Published by JMIR Publications Inc. in JMIR Neurotechnology
- Vol. 4, e67779
Open AccessA Game-Based Mechatronic Device for Digital Rehabilitation of Hand Function After a Stroke: Design, Prototyping, and Feasibility Study
Background: This paper presents an easy-to-use, affordable robotic manipulandum device (RMD) equipped with smart monitoring and assistive technologies to engage in game-based exercise and repetitive task practice. The RMD has been designed to enhance a wide range of fine motor manual dexterity skills, including thumb, finger, and wrist movements. By focusing on finger and hand functions, it extends its utility beyond basic reaching or object transfer movements. Various interchangeable 3D-printed therapy handles of different shapes and sizes can be easily attached to the RMD drive shaft. These handle movements can be used to engage with numerous affordable, commercially available computer games, allowing patients to practice tasks that involve varying movement amplitudes, speeds, precision, and cognitive challenges. Additionally, the device is capable of automatically recording and storing the patient’s real-time performance data on any given computer, integrating assessment into treatment. Objective: A pilot study was conducted with 5 patients with stroke to examine the feasibility and benefits of a 6-week game-based exercise program using the proposed device. Methods: A feasibility study was conducted with 5 participants. Data were collected using the computer game–based upper extremity assessment of manual dexterity and Wolf Motor Function Test (WMFT) before and after the intervention lasting 6 weeks. Results: The pilot study demonstrated that clients’ expectations related to manual dexterity were met. The average improvement in the functional ability score of the WMFT was 14 (SD 3) points, with all participants exceeding the minimal clinically important difference. The average reduction in total time was 30 (SD 14) seconds, with 4 of 5 participants surpassing the minimal clinically important difference. For the computer game–based upper extremity assessment, the average improvement in success rate was 23% (SD 12%), and the average decrease in response time was 105 (SD 44) milliseconds. Conclusions: Findings revealed acceptable, engaging, game-based, and task-oriented training with a high level of compliance. Substantial improvements from pre- to postintervention were observed using the WMFT and assessments of manual dexterity.
- Open Access
- 18 February 2025
- Published by JMIR Publications Inc. in JMIR Rehabilitation and Assistive Technologies
- Vol. 12, e65358
Evaluation of a Game-Based Mechatronic Device for Rehabilitation of Hand-Arm Function in Children With Cerebral Palsy: Feasibility Randomized Controlled Trial
Background: Children with neurodevelopmental disorders, such as cerebral palsy (CP), often experience motor impairments in manual dexterity, which hinder daily tasks and social interactions. Traditional rehabilitation methods require repetitive task practice, which can be difficult for children to sustain due to low engagement. Game-based rehabilitation devices and robots offer a promising alternative by combining therapy with digital play, improving motivation and compliance. However, many systems fail to incorporate actual object manipulation, which is essential for motor learning through sensory feedback. To address this limitation, a low-cost, easy-to-use robotic manipulandum device (RMD) was developed. The RMD enables real-time object manipulation during gameplay while providing assistive force, allowing the practice of a wide range of manual dexterity skills beyond gross reaching. This system offers an engaging and effective rehabilitation approach to enhance hand function in children with CP. Objective: This study aimed to provide evidence for the feasibility and therapeutic value of the RMD game–based exercise program for children with CP. Methods: In total, 34 children with CP, aged 4 to 10 years, were randomly assigned to the experimental group (XG) or the control group (CG). The XG received a computer game–based exercise program using the RMD, focusing on object manipulation tasks, while the CG received task-specific training similar to constraint-induced movement therapy. Both groups received their respective therapy programs 3 times per week for 8 weeks. Semistructured interviews with parents and children, along with qualitative analysis, were conducted to evaluate their experiences with the exercise program. The following outcome measures were used: (1) the Peabody Developmental Motor Scale-2 (PDMS-2) grasping and visual-motor integration subtests and (2) the computer game–based upper extremity (CUE) assessment of manual dexterity. Results: No dropouts occurred during the 8-week program. Both groups showed significant improvements in the PDMS-2 subtests (P<.001) and the CUE assessment of manual dexterity, including success rates (tennis ball: P=.001; cone: P<.001; medicine ball: P=.001; and peanut ball: P<.001) and movement errors (tennis ball: P=.01; cone: P<.001; medicine ball: P=.04; and peanut ball: P<.001). The XG outperformed the CG, showing greater improvements in PDMS-2 grasping (P=.002) and visual-motor integration (P=.01). In the CUE assessment, the XG demonstrated higher success rates (medicine ball: P=.001 and peanut ball: P=.02) and fewer movement errors (cone: P<.001). Parents reported an increase in the children’s independence in daily tasks. Conclusions: This study demonstrates the feasibility, acceptability, and positive outcomes of the RMD game–based exercise program for improving hand function in children with CP. The findings support further research and development of computer game–assisted rehabilitation technologies. Trial Registration: Clinical Trials Registry - India CTRI/2021/07/034903; https://ctri.nic.in/Clinicaltrials/pmaindet2.php?EncHid=NTc4ODU
- 18 February 2025
- Published by JMIR Publications Inc. in JMIR Rehabilitation and Assistive Technologies
- Vol. 12, e65358
Open AccessEvaluation of a Game-Based Mechatronic Device for Rehabilitation of Hand-Arm Function in Children With Cerebral Palsy: Feasibility Randomized Controlled Trial
Background: Children with neurodevelopmental disorders, such as cerebral palsy (CP), often experience motor impairments in manual dexterity, which hinder daily tasks and social interactions. Traditional rehabilitation methods require repetitive task practice, which can be difficult for children to sustain due to low engagement. Game-based rehabilitation devices and robots offer a promising alternative by combining therapy with digital play, improving motivation and compliance. However, many systems fail to incorporate actual object manipulation, which is essential for motor learning through sensory feedback. To address this limitation, a low-cost, easy-to-use robotic manipulandum device (RMD) was developed. The RMD enables real-time object manipulation during gameplay while providing assistive force, allowing the practice of a wide range of manual dexterity skills beyond gross reaching. This system offers an engaging and effective rehabilitation approach to enhance hand function in children with CP. Objective: This study aimed to provide evidence for the feasibility and therapeutic value of the RMD game–based exercise program for children with CP. Methods: In total, 34 children with CP, aged 4 to 10 years, were randomly assigned to the experimental group (XG) or the control group (CG). The XG received a computer game–based exercise program using the RMD, focusing on object manipulation tasks, while the CG received task-specific training similar to constraint-induced movement therapy. Both groups received their respective therapy programs 3 times per week for 8 weeks. Semistructured interviews with parents and children, along with qualitative analysis, were conducted to evaluate their experiences with the exercise program. The following outcome measures were used: (1) the Peabody Developmental Motor Scale-2 (PDMS-2) grasping and visual-motor integration subtests and (2) the computer game–based upper extremity (CUE) assessment of manual dexterity. Results: No dropouts occurred during the 8-week program. Both groups showed significant improvements in the PDMS-2 subtests (P<.001) and the CUE assessment of manual dexterity, including success rates (tennis ball: P=.001; cone: P<.001; medicine ball: P=.001; and peanut ball: P<.001) and movement errors (tennis ball: P=.01; cone: P<.001; medicine ball: P=.04; and peanut ball: P<.001). The XG outperformed the CG, showing greater improvements in PDMS-2 grasping (P=.002) and visual-motor integration (P=.01). In the CUE assessment, the XG demonstrated higher success rates (medicine ball: P=.001 and peanut ball: P=.02) and fewer movement errors (cone: P<.001). Parents reported an increase in the children’s independence in daily tasks. Conclusions: This study demonstrates the feasibility, acceptability, and positive outcomes of the RMD game–based exercise program for improving hand function in children with CP. The findings support further research and development of computer game–assisted rehabilitation technologies. Trial Registration: Clinical Trials Registry - India CTRI/2021/07/034903; https://ctri.nic.in/Clinicaltrials/pmaindet2.php?EncHid=NTc4ODU
- Open Access
- 21 October 2024
- Published by JMIR Publications Inc. in JMIR Preprints
A Game-Based Mechatronic Device for Interactive Rehabilitation of Hand Function Post Stroke: Design, Prototyping and Feasibility Study (Preprint)
BACKGROUND This paper presents an easy-to-use, affordable Rehabilitation Manipulandum Device (RMD) equipped with smart monitoring and assistive technologies to engage in game-based exercise and repetitive task practice. The RMD has been designed to enhance a wide range of fine motor manual dexterity skills, including thumb, finger, and wrist movements. By focusing on finger and hand functions, it extends its utility beyond basic reaching or object transfer movements. Various interchangeable 3D-printed therapy handles of different shapes and sizes can be easily attached to the RMD drive shaft. These handle movements can be utilized to engage with numerous affordable, commercially available computer games, allowing patients to practice tasks that involve varying movement amplitudes, speeds, precision, and cognitive challenges. Additionally, the device is capable of automatically recording and storing the patient's real-time performance data on any given computer, integrating assessment into treatment. OBJECTIVE A pilot study was conducted with five stroke patients to examine the feasibility and benefits of a 6-week game-based exercise program using the proposed device. METHODS A feasibility study was conducted with 5 participants. Data was collected using the CUE assessment and WMFT pre and post intervention lasting 6 weeks. RESULTS The pilot study demonstrated that clients’ expectations related to manual dexterity were met. CONCLUSIONS Findings revealed acceptable, engaging, game-based, and task-oriented training with a high level of compliance. Substantial improvements from pre- to post-intervention were observed using the Wolf Motor Function Test and assessments of manual dexterity. CLINICALTRIAL Clinical Trials Registry - NCT05071885
- 21 October 2024
- Published by JMIR Publications Inc. in JMIR Preprints
Open AccessA Game-Based Mechatronic Device for Interactive Rehabilitation of Hand Function Post Stroke: Design, Prototyping and Feasibility Study (Preprint)
BACKGROUND This paper presents an easy-to-use, affordable Rehabilitation Manipulandum Device (RMD) equipped with smart monitoring and assistive technologies to engage in game-based exercise and repetitive task practice. The RMD has been designed to enhance a wide range of fine motor manual dexterity skills, including thumb, finger, and wrist movements. By focusing on finger and hand functions, it extends its utility beyond basic reaching or object transfer movements. Various interchangeable 3D-printed therapy handles of different shapes and sizes can be easily attached to the RMD drive shaft. These handle movements can be utilized to engage with numerous affordable, commercially available computer games, allowing patients to practice tasks that involve varying movement amplitudes, speeds, precision, and cognitive challenges. Additionally, the device is capable of automatically recording and storing the patient's real-time performance data on any given computer, integrating assessment into treatment. OBJECTIVE A pilot study was conducted with five stroke patients to examine the feasibility and benefits of a 6-week game-based exercise program using the proposed device. METHODS A feasibility study was conducted with 5 participants. Data was collected using the CUE assessment and WMFT pre and post intervention lasting 6 weeks. RESULTS The pilot study demonstrated that clients’ expectations related to manual dexterity were met. CONCLUSIONS Findings revealed acceptable, engaging, game-based, and task-oriented training with a high level of compliance. Substantial improvements from pre- to post-intervention were observed using the Wolf Motor Function Test and assessments of manual dexterity. CLINICALTRIAL Clinical Trials Registry - NCT05071885
- Open Access
- 13 August 2024
- Published by JMIR Publications Inc. in JMIR Preprints
Evaluation of a Game-Based Mechatronic Device for Rehabilitation of Hand-Arm Function in Children With Cerebral Palsy: Feasibility Randomized Controlled Trial (Preprint)
Journal of Medical Internet Research - International Scientific Journal for Medical Research, Information and Communication on the Internet #Preprint #PeerReviewMe: Warning: This is a unreviewed preprint. Readers are warned that the document has not been peer-reviewed by expert/patient reviewers or an academic editor, may contain misleading claims, and is likely to undergo changes before final publication, if accepted, or may have been rejected/withdrawn. Readers with interest and expertise are encouraged to sign up as peer-reviewer, if the paper is within an open peer-review period. Please cite this preprint only for review purposes or for grant applications and CVs (if you are the author). Background: Children with neurodevelopmental disorders, such as cerebral palsy (CP), often experience motor impairments in manual dexterity, which hinder daily tasks and social interactions. Traditional rehabilitation methods require repetitive task practice, which can be difficult for children to sustain due to low engagement. Game-based rehabilitation devices and robots offer a promising alternative by combining therapy with digital play, improving motivation and compliance. However, many systems fail to incorporate actual object manipulation, which is essential for motor learning through sensory feedback. To address this limitation, a low-cost, easy-to-use robotic manipulandum device (RMD) was developed. The RMD enables real-time object manipulation during gameplay while providing assistive force, allowing the practice of a wide range of manual dexterity skills beyond gross reaching. This system offers an engaging and effective rehabilitation approach to enhance hand function in children with CP. Objective: This study aimed to provide evidence for the feasibility and therapeutic value of the RMD game–based exercise program for children with CP. Methods: In total, 34 children with CP, aged 4 to 10 years, were randomly assigned to the experimental group (XG) or the control group (CG). The XG received a computer game–based exercise program using the RMD, focusing on object manipulation tasks, while the CG received task-specific training similar to constraint-induced movement therapy. Both groups received their respective therapy programs 3 times per week for 8 weeks. Semistructured interviews with parents and children, along with qualitative analysis, were conducted to evaluate their experiences with the exercise program. The following outcome measures were used: (1) the Peabody Developmental Motor Scale-2 (PDMS-2) grasping and visual-motor integration subtests and (2) the computer game–based upper extremity (CUE) assessment of manual dexterity. Results: No dropouts occurred during the 8-week program. Both groups showed significant improvements in the PDMS-2 subtests (P<.001) and the CUE assessment of manual dexterity, including success rates (tennis ball: P=.001; cone: P<.001; medicine ball: P=.001; and peanut ball: P<.001) and movement errors (tennis ball: P=.01; cone: P<.001; medicine ball: P=.04; and peanut ball: P<.001). The XG outperformed the CG, showing greater improvements in PDMS-2 grasping (P=.002) and visual-motor integration (P=.01). In the CUE assessment, the XG demonstrated higher success rates (medicine ball: P=.001 and peanut ball: P=.02) and fewer movement errors (cone: P<.001). Parents reported an increase in the children’s independence in daily tasks. Conclusions: This study demonstrates the feasibility, acceptability, and positive outcomes of the RMD game–based exercise program for improving hand function in children with CP. The findings support further research and development of computer game–assisted rehabilitation technologies. Trial Registration: Clinical Trials Registry - India CTRI/2021/07/034903; https://ctri.nic.in/Clinicaltrials/pmaindet2.php?EncHid=NTc4ODU
- 13 August 2024
- Published by JMIR Publications Inc. in JMIR Preprints
Open AccessEvaluation of a Game-Based Mechatronic Device for Rehabilitation of Hand-Arm Function in Children With Cerebral Palsy: Feasibility Randomized Controlled Trial (Preprint)
Journal of Medical Internet Research - International Scientific Journal for Medical Research, Information and Communication on the Internet #Preprint #PeerReviewMe: Warning: This is a unreviewed preprint. Readers are warned that the document has not been peer-reviewed by expert/patient reviewers or an academic editor, may contain misleading claims, and is likely to undergo changes before final publication, if accepted, or may have been rejected/withdrawn. Readers with interest and expertise are encouraged to sign up as peer-reviewer, if the paper is within an open peer-review period. Please cite this preprint only for review purposes or for grant applications and CVs (if you are the author). Background: Children with neurodevelopmental disorders, such as cerebral palsy (CP), often experience motor impairments in manual dexterity, which hinder daily tasks and social interactions. Traditional rehabilitation methods require repetitive task practice, which can be difficult for children to sustain due to low engagement. Game-based rehabilitation devices and robots offer a promising alternative by combining therapy with digital play, improving motivation and compliance. However, many systems fail to incorporate actual object manipulation, which is essential for motor learning through sensory feedback. To address this limitation, a low-cost, easy-to-use robotic manipulandum device (RMD) was developed. The RMD enables real-time object manipulation during gameplay while providing assistive force, allowing the practice of a wide range of manual dexterity skills beyond gross reaching. This system offers an engaging and effective rehabilitation approach to enhance hand function in children with CP. Objective: This study aimed to provide evidence for the feasibility and therapeutic value of the RMD game–based exercise program for children with CP. Methods: In total, 34 children with CP, aged 4 to 10 years, were randomly assigned to the experimental group (XG) or the control group (CG). The XG received a computer game–based exercise program using the RMD, focusing on object manipulation tasks, while the CG received task-specific training similar to constraint-induced movement therapy. Both groups received their respective therapy programs 3 times per week for 8 weeks. Semistructured interviews with parents and children, along with qualitative analysis, were conducted to evaluate their experiences with the exercise program. The following outcome measures were used: (1) the Peabody Developmental Motor Scale-2 (PDMS-2) grasping and visual-motor integration subtests and (2) the computer game–based upper extremity (CUE) assessment of manual dexterity. Results: No dropouts occurred during the 8-week program. Both groups showed significant improvements in the PDMS-2 subtests (P<.001) and the CUE assessment of manual dexterity, including success rates (tennis ball: P=.001; cone: P<.001; medicine ball: P=.001; and peanut ball: P<.001) and movement errors (tennis ball: P=.01; cone: P<.001; medicine ball: P=.04; and peanut ball: P<.001). The XG outperformed the CG, showing greater improvements in PDMS-2 grasping (P=.002) and visual-motor integration (P=.01). In the CUE assessment, the XG demonstrated higher success rates (medicine ball: P=.001 and peanut ball: P=.02) and fewer movement errors (cone: P<.001). Parents reported an increase in the children’s independence in daily tasks. Conclusions: This study demonstrates the feasibility, acceptability, and positive outcomes of the RMD game–based exercise program for improving hand function in children with CP. The findings support further research and development of computer game–assisted rehabilitation technologies. Trial Registration: Clinical Trials Registry - India CTRI/2021/07/034903; https://ctri.nic.in/Clinicaltrials/pmaindet2.php?EncHid=NTc4ODU