Hajun Yoo
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Hajun Yoo has a total of 23 co-authors. Here are the top co-authors by number of shared publications:
- Donghyun Kim
Yonsei University
3 shared publications Hyunwoong Lee
School of Electrical and Electronic Engineering, Yonsei University, Seoul, Korea
2 shared publications- Kwanhwi Ko
School of Electrical and Electronic Engineering, Yonsei University, Seoul, Korea
2 shared publications Sukhyeon Ka
School of Electrical and Electronic Engineering, Yonsei University, Seoul, Korea
2 shared publications- Biagio Mandracchia
Laboratorio de Procesado de Imagen, Universidad de Valladolid
1 shared publication DuckJong Suh
Materials Research Team, Display Research Center Samsung Display Co., LTD. 1 Samsung‐ro, Giheung‐Gu Yongin‐si Gyeonggi‐do 17113 Republic of Korea
1 shared publication
Latest Publications
- Open Access
- 10 November 2026
- Published by Royal Society of Chemistry (RSC) in Lab on a Chip
- Vol. 26 (22) , 5875-5897
Three-dimensional imaging flow cytometry: current trends and future perspectives
This review distinguishes between scanning and nonscanning methods for 3D imaging flow cytometry (IFC) and evaluates their optical principles, trade-offs, and biological applications to outline future miniaturized, AI-enabled, autonomous platforms.
- 10 November 2026
- Published by Royal Society of Chemistry (RSC) in Lab on a Chip
- Vol. 26 (22) , 5875-5897
Open AccessThree-dimensional imaging flow cytometry: current trends and future perspectives
This review distinguishes between scanning and nonscanning methods for 3D imaging flow cytometry (IFC) and evaluates their optical principles, trade-offs, and biological applications to outline future miniaturized, AI-enabled, autonomous platforms.
- Open Access
- 20 October 2025
- Published by Springer Nature in Nature Communications
- Vol. 16 (1) , 1-11
Near-isotropic super-resolution microscopy with axial interference speckle illumination
Super-resolution microscopy has pushed the limits of biological imaging. However, achieving isotropic resolution across all spatial dimensions remains a challenge and often requires a complex and highly sensitive optical setup. Herein, we introduce axial interference speckle illumination-engineered structured illumination microscopy (AXIS-SIM), a minimal-modification approach that utilizes constructive interference from a simple back-reflecting mirror to enhance the axial resolution without additional phase control or complex beam shaping. AXIS-SIM provides superior optical sectioning and improves axial resolution beyond the typical axial resolution of conventional 3D-structured illumination microscopy (~300 nm), achieving lateral and axial resolutions of 108.5 and 140.1 nm, respectively. Furthermore, its robustness against alignment errors and sample-induced aberrations enables high-throughput 3D super-resolution imaging of diverse biological specimens. We demonstrate its potential by visualizing the 3D morphology of cell membranes, resolving the nanoscale distribution of lysosomes and microtubules and tracking lysosomal movements with enhanced axial clarity.
- 20 October 2025
- Published by Springer Nature in Nature Communications
- Vol. 16 (1) , 1-11
Open AccessNear-isotropic super-resolution microscopy with axial interference speckle illumination
Super-resolution microscopy has pushed the limits of biological imaging. However, achieving isotropic resolution across all spatial dimensions remains a challenge and often requires a complex and highly sensitive optical setup. Herein, we introduce axial interference speckle illumination-engineered structured illumination microscopy (AXIS-SIM), a minimal-modification approach that utilizes constructive interference from a simple back-reflecting mirror to enhance the axial resolution without additional phase control or complex beam shaping. AXIS-SIM provides superior optical sectioning and improves axial resolution beyond the typical axial resolution of conventional 3D-structured illumination microscopy (~300 nm), achieving lateral and axial resolutions of 108.5 and 140.1 nm, respectively. Furthermore, its robustness against alignment errors and sample-induced aberrations enables high-throughput 3D super-resolution imaging of diverse biological specimens. We demonstrate its potential by visualizing the 3D morphology of cell membranes, resolving the nanoscale distribution of lysosomes and microtubules and tracking lysosomal movements with enhanced axial clarity.
- 19 February 2025
- Published by Wiley in Laser & Photonics Reviews
- Vol. 19 (10)
Metasurface‐Integrated Organic Light‐Emitting Diodes: Analysis of Spectral Effects on Theoretical and Experimental Performance
Organic light‐emitting diodes (OLEDs) have emerged as a leading display technology and become rapidly embraced in commercial applications. In this paper, we explore the integration of metasurface (MS) designs for polarizer‐free top‐emitting OLEDs (TOLEDs) with enhanced absorption of ambient light. From the performance evaluated by varying the geometrical parameters of the MS, it is found that the broadband absorption in the long wavelength range, associated with the localized surface plasmon mode of the MS, can be tuned by adjusting these parameters. Optimizing these parameters can effectively localize and enhance near‐fields at the MS edges, thereby reducing the reflectance of MS‐integrated TOLEDs (MI‐TOLEDs) under ambient light. An optimized MS may balance reduced reflectance with minimal emission loss from TOLEDs. Numerical results suggest that MI‐TOLEDs can improve spectral out‐coupled light intensity and overall angular enhancement of the out‐coupled power by at least 50% and 45%, respectively, over conventional TOLED. In the whole visible wavelength range, the MI‐TOLED shows 48% lower reflectance compared to conventional TOLED, which is confirmed by experimental data measured from the MS optical cavity. Changes in encapsulation thickness influence the surface plasmon polariton mode, shifting resonance conditions in the reflectance spectra within the short wavelength range.
- 19 February 2025
- Published by Wiley in Laser & Photonics Reviews
- Vol. 19 (10)
Metasurface‐Integrated Organic Light‐Emitting Diodes: Analysis of Spectral Effects on Theoretical and Experimental Performance
Organic light‐emitting diodes (OLEDs) have emerged as a leading display technology and become rapidly embraced in commercial applications. In this paper, we explore the integration of metasurface (MS) designs for polarizer‐free top‐emitting OLEDs (TOLEDs) with enhanced absorption of ambient light. From the performance evaluated by varying the geometrical parameters of the MS, it is found that the broadband absorption in the long wavelength range, associated with the localized surface plasmon mode of the MS, can be tuned by adjusting these parameters. Optimizing these parameters can effectively localize and enhance near‐fields at the MS edges, thereby reducing the reflectance of MS‐integrated TOLEDs (MI‐TOLEDs) under ambient light. An optimized MS may balance reduced reflectance with minimal emission loss from TOLEDs. Numerical results suggest that MI‐TOLEDs can improve spectral out‐coupled light intensity and overall angular enhancement of the out‐coupled power by at least 50% and 45%, respectively, over conventional TOLED. In the whole visible wavelength range, the MI‐TOLED shows 48% lower reflectance compared to conventional TOLED, which is confirmed by experimental data measured from the MS optical cavity. Changes in encapsulation thickness influence the surface plasmon polariton mode, shifting resonance conditions in the reflectance spectra within the short wavelength range.
- Open Access
- 16 October 2024
- Published by Royal Society of Chemistry (RSC) in The Analyst
- Vol. 149 (23) , 5649-5656
Surface-enhanced Raman spectroscopy with single cell manipulation by microfluidic dielectrophoresis
The combination of dielectrophoresis and surface-enhanced Raman spectroscopy provides an effective method for analyzing the Raman characteristics and the dielectrophoretic behavior of polystyrene beads and U-87MG cells in a microfluidic environment.
- 16 October 2024
- Published by Royal Society of Chemistry (RSC) in The Analyst
- Vol. 149 (23) , 5649-5656
Open AccessSurface-enhanced Raman spectroscopy with single cell manipulation by microfluidic dielectrophoresis
The combination of dielectrophoresis and surface-enhanced Raman spectroscopy provides an effective method for analyzing the Raman characteristics and the dielectrophoretic behavior of polystyrene beads and U-87MG cells in a microfluidic environment.