RLRochelle Lykawka

Rochelle Lykawka

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Rochelle Lykawka has a total of 22 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Establishing typical dose values in fluoroscopy-guided paediatric central venous catheter placement procedures in a large university hospital

    by Georgia A.A. Alves, Rochelle Lykawka, Thatiane A. Pianoschi, João V.B. Valença, Carlos Ubeda, Mauricio Anés, Alexandre Bacelar, Henrique Trombini

  • Open Access

    Metodologia para Validação de Equipamento de Proteção Individual Ocular Para Uso Com Laser em Procedimentos Médicos

    by Cássio Moura, Maiara Cecchin, Rochelle Lykawka, Alexandre Bacelar

    Feixes de laser são amplamente utilizados em instituições de saúde e exigem proteção adequada para o operador e o paciente. Normas internacionais fornecem orientações sobre como exercer essa proteção, especialmente em relação ao olho, que é muito sensível à radiação óptica. Óculos devem fornecer proteção suficiente para comprimentos de onda específicos do feixe de laser utilizado no procedimento médico. Neste trabalho, apresentamos um protocolo sobre como avaliar se um óculos é adequado para um emissor de laser específico. Valores reais foram utilizados nos cálculos e devem ser adaptados para cada situação.

  • Open Access

    Diagnostic reference levels in interventional radiology: a systematic review

    by Iana Quintanilha de Borba, Rochelle Lykawka, Nayron Medeiros Soares, Joaquim Maurício da Motta Leal Filho, Alexandre Bacelar, Matheus de Lima Ruffini, Adolfo Moraes de Souza, Fabiano Reis, Juliana Ávila Duarte

    Objective: To comprehensively and impartially analyze the scientific evidence available for establishing diagnostic reference levels (DRLs) in interventional radiology. Method: This was a systematic review conducted in accordance with the Preferred Reporting Items for Systematic Reviews and Meta-Analyses guidelines. The search focused on studies related to interventional radiology and DRLs in PubMed/Medline and Embase. Studies involving computed tomography-guided procedures, studies with incomplete data, and systematic reviews were excluded. Two independent reviewers evaluated the studies, resolving discrepancies with a third reviewer. Articles were tabulated with information such as title, publication year, procedures, DRL values, and type of equipment used. Results: A total of 475 articles were identified. After duplicates had been excluded and eligibility criteria had been applied, the final sample comprised 30 articles. Most DRL values (73%) were reported at the local level, as defined by International Commission on Radiological Protection criteria, representing typical dose values from a sample within one or a few institutions. A total of 113 procedures were identified, with endovascular aneurysm repair and nephrostomy being the most frequently reported. We identified DRLs at national and regional scales, predominantly within Europe. Influencing factors included technology, operator experience, specific protocols, and optimization strategies. The analysis also identified a lack of longitudinal studies assessing changes over time. The use of dose management software emerged as an effective tool for facilitating data collection and DRL establishment. Conclusion: The lack of standardized procedural terminology hindered direct DRL comparisons. Our findings highlight a predominance of European studies and emphasize the need for broader international efforts to improve DRL implementation.


  • Open Access

    Fatores que influenciam a exatidão do indicador dos descritores de dose em radiologia intervencionista: Avaliação de Protocolos

    by Julia Forell, Rochelle Lykawka, Alexandre Bacelar, Maurício Anés, Janine Dias, Isadora Veiga da Rosa, Raíssa Xavier Contassot, Thatiane A. Pianoschi

    O controle de qualidade na Radiologia Intervencionista é um pilar fundamental para mitigar os riscos associados às doses de radiação administradas tanto aos pacientes quanto à equipe clínica. Testes como exatidão do indicador de produto dose-área, do kerma no ponto de referência de entrada no paciente e valores de taxa de kerma no ar de referência são de extrema importância para a segurança do paciente e do corpo clínico e necessitam de instruções para a sua realização. No entanto, não existe na literatura nacional a descrição de uma metodologia padronizada para conduzir testes que assegurem a precisão e a segurança dos procedimentos. Desta forma, este trabalho tem como objetivo avaliar e testar os protocolos disponíveis na literatura internacional para os testes citados, em diferentes equipamentos entre arcos cirúrgicos e angiógrafos. A metodologia envolve uma parte experimental referente à exatidão dos testes e da discrepância relativa entre os protocolos, e uma parte observacional, que avalia os itens necessários para um bom funcionamento dos equipamentos intervencionistas. A partir dos resultados encontrados, pode-se perceber que as medidas dos descritores de dose apresentaram comportamentos distintos entre os protocolos e entre equipamentos, devido a diversas variáveis que influenciam na resposta, como a incerteza da área irradiada, a precisão dos monitores e a calibração dos medidores utilizados. De acordo com a análise observacional, dois equipamentos se encontram em conformidade parcial ou não conformidade. A partir deste trabalho foi possível perceber que ainda há muito o que se discutir sobre os testes de controle de qualidade. A preocupação com a radioproteção e a otimização de doses em fluoroscopia, tanto dos profissionais como dos pacientes exige um eficiente controle de qualidade no equipamento, visando um desempenho satisfatório e adequado nos serviços de radiologia intervencionista, reduzindo, assim, exposições desnecessárias e doses elevadas.