Rajeev Sharma
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Rajeev Sharma has a total of 8 co-authors. Here are the top co-authors by number of shared publications:
- Ayush Yadav
VIT-AP University
1 shared publication - Brundavanam Satyasai
School of Electronics Engineering, VIT-AP University, Amaravathi, Andhra Pradesh, India
1 shared publication - Deepak Mohan Soni
HP Govt Dental College and Hospital, Shimla, Himachal Pradesh, India
1 shared publication - Kodali Radha
Department of Electronics and Communication Engineering, Velagapudi Ramakrishna Siddhartha Engineering College, Vijayawada, India
1 shared publication - Konda Gurava Reddy Atla1 shared publication
- Krishna
VIT-AP University
1 shared publication
Latest Publications
- Open Access
- 24 February 2025
- Published by Elsevier in Alexandria Engineering Journal
- Vol. 120, 532-546
Motor imagery classification using a novel CNN in EEG-BCI with common average reference and sliding window techniques
- 24 February 2025
- Published by Elsevier in Alexandria Engineering Journal
- Vol. 120, 532-546
Open AccessMotor imagery classification using a novel CNN in EEG-BCI with common average reference and sliding window techniques
- 11 December 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 25 (2) , 3998-4005
CM-VGG16: ConvMixer-Enhanced VGG16 Model for Automatic Detection of Heart Valve Diseases From Phonocardiogram Signals
The absence of medical resources at remote places prevents many patients from receiving a prompt and accurate diagnosis of cardiovascular disorders. To address this, we proposed a novel deep learning model based on partially fine-tuned VGG16 and ConvMixer for the automatic identification of various heart valve diseases from phonocardiogram (PCG) signals. The method involves preprocessing PCG signals and converting them into Gammatone filterbank (GFB) based 2D time-frequency images. In order to generate time-frequency images, we utilized Gammatonegram, Gammtone Cepstral Coefficients (GTCC), and Gammatone Discrete Wavelet Coefficients (GDWC) techniques. These time-frequency images are augmented to reduce overfitting and then fed into a VGG16 model. Partial fine-tuning of the VGG16 model accelerates convergence and further improves performance. By extending the VGG16 model with ConvMixer, Global Average-Pooling, Dense, and Softmax layers, we enhance its capacity to capture intricate patterns. The ConvMixer enriches spatial and channel-wise features using Depthwise and Pointwise convolutions. We also performed an ablation analysis to highlight the effect of ConvMixer with VGG16. In addition, performance evaluation based on precision, recall, f1 score, test accuracy, and validation accuracy reveal the efficacy of the proposed method. Comparisons between Gammatonegram, GTCC and GDWC show superior performance of Gammatonegram, achieving a test accuracy of 99.60% and validation accuracy of 99.75%. Our approach demonstrates significant advances over existing methods, offering a promising solution for remote diagnosis of heart valve diseases.
- 11 December 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 25 (2) , 3998-4005
CM-VGG16: ConvMixer-Enhanced VGG16 Model for Automatic Detection of Heart Valve Diseases From Phonocardiogram Signals
The absence of medical resources at remote places prevents many patients from receiving a prompt and accurate diagnosis of cardiovascular disorders. To address this, we proposed a novel deep learning model based on partially fine-tuned VGG16 and ConvMixer for the automatic identification of various heart valve diseases from phonocardiogram (PCG) signals. The method involves preprocessing PCG signals and converting them into Gammatone filterbank (GFB) based 2D time-frequency images. In order to generate time-frequency images, we utilized Gammatonegram, Gammtone Cepstral Coefficients (GTCC), and Gammatone Discrete Wavelet Coefficients (GDWC) techniques. These time-frequency images are augmented to reduce overfitting and then fed into a VGG16 model. Partial fine-tuning of the VGG16 model accelerates convergence and further improves performance. By extending the VGG16 model with ConvMixer, Global Average-Pooling, Dense, and Softmax layers, we enhance its capacity to capture intricate patterns. The ConvMixer enriches spatial and channel-wise features using Depthwise and Pointwise convolutions. We also performed an ablation analysis to highlight the effect of ConvMixer with VGG16. In addition, performance evaluation based on precision, recall, f1 score, test accuracy, and validation accuracy reveal the efficacy of the proposed method. Comparisons between Gammatonegram, GTCC and GDWC show superior performance of Gammatonegram, achieving a test accuracy of 99.60% and validation accuracy of 99.75%. Our approach demonstrates significant advances over existing methods, offering a promising solution for remote diagnosis of heart valve diseases.
- 3 November 2024
- Published by Springer Nature
- p. 97-119
IoT-Based Intelligent Home Automation System Using IFTTT with Google Assistant
- 3 November 2024
- Published by Springer Nature
- p. 97-119
IoT-Based Intelligent Home Automation System Using IFTTT with Google Assistant
- Open Access
- 19 January 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 12, 13986-14004
Raw Waveform-Based Custom Scalogram CRNN in Cardiac Abnormality Diagnosis
Cardiovascular disease is a significant cause of death worldwide, emphasizing the crucial need for timely detection and diagnosis of heart abnormalities. This study presents a new approach that utilizes deep learning models to diagnose cardiac issues by analyzing raw phonocardiogram (PCG) signals. The proposed method introduces a novel technique called custom scalogram-based convolutional recurrent neural network (CS-CRNN). Diverging from conventional techniques, this model directly handles the raw PCG signals. These signals undergo a transformation into scalogram images within the initial layer of the CRNN architecture, without incorporating any learnable parameters. The results obtained from the CS-CRNN model are compared with traditional feature-based recurrent neural network (RNN) models. The comparison demonstrates comparable performance in both binary classification (normal and abnormal categories) and multiclass classification (5 categories). The CS-CRNN model directly handles raw PCG data and employs data augmentation to enhance performance on small datasets. It achieves an accuracy of 99.6% for binary classification and 98.6% and 99.7% before and after optimization for multiclass classification on the augmented dataset. The results show that the CS-CRNN model offers comparable performance to traditional methods, making it a promising tool for diagnosing cardiac abnormalities.
- 19 January 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 12, 13986-14004
Open AccessRaw Waveform-Based Custom Scalogram CRNN in Cardiac Abnormality Diagnosis
Cardiovascular disease is a significant cause of death worldwide, emphasizing the crucial need for timely detection and diagnosis of heart abnormalities. This study presents a new approach that utilizes deep learning models to diagnose cardiac issues by analyzing raw phonocardiogram (PCG) signals. The proposed method introduces a novel technique called custom scalogram-based convolutional recurrent neural network (CS-CRNN). Diverging from conventional techniques, this model directly handles the raw PCG signals. These signals undergo a transformation into scalogram images within the initial layer of the CRNN architecture, without incorporating any learnable parameters. The results obtained from the CS-CRNN model are compared with traditional feature-based recurrent neural network (RNN) models. The comparison demonstrates comparable performance in both binary classification (normal and abnormal categories) and multiclass classification (5 categories). The CS-CRNN model directly handles raw PCG data and employs data augmentation to enhance performance on small datasets. It achieves an accuracy of 99.6% for binary classification and 98.6% and 99.7% before and after optimization for multiclass classification on the augmented dataset. The results show that the CS-CRNN model offers comparable performance to traditional methods, making it a promising tool for diagnosing cardiac abnormalities.
- Open Access
- 15 November 2022
- Published by SASPR Edu International Pvt. Ltd in EAS Journal of Dentistry and Oral Medicine
- Vol. 4 (6) , 132-140
Retraction of Anterior Teeth with Temporary Anchorage Devices (TADS) – A Review
- 15 November 2022
- Published by SASPR Edu International Pvt. Ltd in EAS Journal of Dentistry and Oral Medicine
- Vol. 4 (6) , 132-140
Open AccessRetraction of Anterior Teeth with Temporary Anchorage Devices (TADS) – A Review