Hongliang Wang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Hongliang Wang has a total of 39 co-authors. Here are the top co-authors by number of shared publications:
Feng Zhang
State Key Laboratory of Extreme Environment Optoelectronic Dynamic Measurement Technology and Instrument, North University of China, Taiyuan, China
5 shared publicationsQi Ding
4 shared publicationsRunze Yang
4 shared publicationsPeng Zhang
State Key Laboratory of Extreme Environment Optoelectronic Dynamic Measurement Technology and Instrument, North University of China, Taiyuan, China
3 shared publications- Wendong Zhang
North University of China
3 shared publications Jie Li
2 shared publications
Latest Publications
- 29 October 2026
- Published by Elsevier in Journal of Hydrology
- Vol. 681
HydroFlow: A robust and lightweight network for river surface velocimetry on edge devices via semi-supervised learning
- 29 October 2026
- Published by Elsevier in Journal of Hydrology
- Vol. 681
HydroFlow: A robust and lightweight network for river surface velocimetry on edge devices via semi-supervised learning
- 28 March 2026
- Published by Elsevier in Ceramics International
- Vol. 52 (13) , 23343-23352
High-temperature PZT-based 1–3 piezoelectric composites enabled by a PI/PEEK hybrid matrix for downhole ultrasonic transducers
- 28 March 2026
- Published by Elsevier in Ceramics International
- Vol. 52 (13) , 23343-23352
High-temperature PZT-based 1–3 piezoelectric composites enabled by a PI/PEEK hybrid matrix for downhole ultrasonic transducers
- 26 March 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 75 (00189456) , 1-18
Rapid High-Resolution Breast Imaging With Ring-Array Multi-Subarray Synthetic-Aperture Frequency-Domain Ultrasound Computed Tomography Method
Ultrasound computed tomography (USCT) using ring array technology has shown great potential in breast diagnosis. This study addresses the problems of low imaging resolution and long acquisition time in USCT for breast diagnosis by proposing a frequency domain imaging method based on a ring array and multi-subarray synthetic aperture. This method achieves omnidirectional transmission and reception through beam focusing synthesis, enabling tomographic scanning, supporting complete 3D CT reconstruction, and simulating the performance of a large-aperture system with a small array, achieving sub-millimeter-level imaging resolution. By combining a frequency delay-compensated beamforming method and a designed adjustment strategy, effective signal components are filtered from the large amount of data received by the ring array, completing lossless signal conversion between the time and frequency domains, reducing the reconstruction time to less than 6 seconds, a 7.4-fold improvement over traditional time-domain methods and approximately 2.6 times faster than existing clinical breast CT systems. Experiments show that The breast tissue membrane reconstruction demonstrates high fidelity, and Preliminary clinical pilot study and MRI results are trend-level agreement in boundary, and spatial distribution, validating the effectiveness and accuracy of this method in clinical practice.
- 26 March 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 75 (00189456) , 1-18
Rapid High-Resolution Breast Imaging With Ring-Array Multi-Subarray Synthetic-Aperture Frequency-Domain Ultrasound Computed Tomography Method
Ultrasound computed tomography (USCT) using ring array technology has shown great potential in breast diagnosis. This study addresses the problems of low imaging resolution and long acquisition time in USCT for breast diagnosis by proposing a frequency domain imaging method based on a ring array and multi-subarray synthetic aperture. This method achieves omnidirectional transmission and reception through beam focusing synthesis, enabling tomographic scanning, supporting complete 3D CT reconstruction, and simulating the performance of a large-aperture system with a small array, achieving sub-millimeter-level imaging resolution. By combining a frequency delay-compensated beamforming method and a designed adjustment strategy, effective signal components are filtered from the large amount of data received by the ring array, completing lossless signal conversion between the time and frequency domains, reducing the reconstruction time to less than 6 seconds, a 7.4-fold improvement over traditional time-domain methods and approximately 2.6 times faster than existing clinical breast CT systems. Experiments show that The breast tissue membrane reconstruction demonstrates high fidelity, and Preliminary clinical pilot study and MRI results are trend-level agreement in boundary, and spatial distribution, validating the effectiveness and accuracy of this method in clinical practice.
- Open Access
- 4 February 2026
- Published by Elsevier in SSRN Electronic Journal
Physics-Informed Microstructure Modeling and Data-DrivenOptimization of 1–3 Piezoelectric Composites for ExtremeEnvironments
Piezoelectric 1–3 composites for downhole sensing must maintain reliable electromechanical coupling under extreme temperature and pressure, yet classical micromechanics often becomes inaccurate in high-contrast ceramic–polymer systems and high-fidelity simulations are too costly for largedesign exploration. Here we propose an integrated workflow that couples improved micromechanical modeling, a physics-guided deep neural network (PG-DNN), and surrogate-based multi-objectiveoptimization for rapid structure–property prediction and design. An aspect-ratio-corrected Eshelbyformulation, interfacial polarization correction, and thermo–pressure coupling laws are used to builda curated database spanning 117 material combinations and wide microstructural/operating ranges.The PG-DNN embeds constitutive relations and stability constraints to predict six key performancemetrics within milliseconds with high accuracy and generalization. Optimization identifies PMN35PT/epoxy with high volume fraction and high aspect ratio as the best overall performer under representative downhole conditions, while sensitivity and uncertainty analyses reveal a “shrinkage” ofthe feasible design space and a shift of dominant mechanisms with operating conditions.
- 4 February 2026
- Published by Elsevier in SSRN Electronic Journal
Open AccessPhysics-Informed Microstructure Modeling and Data-DrivenOptimization of 1–3 Piezoelectric Composites for ExtremeEnvironments
Piezoelectric 1–3 composites for downhole sensing must maintain reliable electromechanical coupling under extreme temperature and pressure, yet classical micromechanics often becomes inaccurate in high-contrast ceramic–polymer systems and high-fidelity simulations are too costly for largedesign exploration. Here we propose an integrated workflow that couples improved micromechanical modeling, a physics-guided deep neural network (PG-DNN), and surrogate-based multi-objectiveoptimization for rapid structure–property prediction and design. An aspect-ratio-corrected Eshelbyformulation, interfacial polarization correction, and thermo–pressure coupling laws are used to builda curated database spanning 117 material combinations and wide microstructural/operating ranges.The PG-DNN embeds constitutive relations and stability constraints to predict six key performancemetrics within milliseconds with high accuracy and generalization. Optimization identifies PMN35PT/epoxy with high volume fraction and high aspect ratio as the best overall performer under representative downhole conditions, while sensitivity and uncertainty analyses reveal a “shrinkage” ofthe feasible design space and a shift of dominant mechanisms with operating conditions.
- Top Cited Papers
- 3 February 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 75 (00189456) , 1-12
Directionally Regularized Two-Stage Calibration for Cross-Shaped MGT Sensor Arrays With Physics-Inspired Error Modeling
Accurate calibration of magnetic gradient tensor (MGT) sensor arrays requires correcting both the magnitude and directional responses of individual triaxial magnetometers. Conventional scalar-based calibration methods focus solely on fitting the magnitude of the magnetic field vector, lacking control over directional accuracy and thereby compromising the reliability of MGT construction under field conditions. To overcome these limitations, this paper proposes a directionally regularized two-stage calibration framework specifically for cross-shaped MGT fluxgate sensor arrays. A physically interpretable twelve-parameter error model is formulated to decouple sensor-internal distortions from array-level orientation misalignments. Crucially, a directional regularization term is incorporated into the calibration objective function to enforce vector alignment across the array. Furthermore, a high-precision triaxial fluxgate sensor is employed as an internal reference, enabling fully self-contained calibration without external field generators or scalar magnetometers. For accurate estimation of the calibration parameters, a two-stage optimization strategy based on Differential Evolution (DE) is developed, in which all parameters are coarsely estimated via magnitude consistency in the first stage, followed by refined alignment of array orientations via directional regularization in the second stage. Field experiments conducted over six independent trials validate the effectiveness and reproducibility of the proposed framework, yielding an overall mean magnitude RMSE of approximately 5.92 nT and a mean angular deviation of 0.07°. These results confirm that the proposed framework enables accurate and robust compensation of MGT sensor arrays in practical environments.
- 3 February 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 75 (00189456) , 1-12
Top Cited PapersDirectionally Regularized Two-Stage Calibration for Cross-Shaped MGT Sensor Arrays With Physics-Inspired Error Modeling
Accurate calibration of magnetic gradient tensor (MGT) sensor arrays requires correcting both the magnitude and directional responses of individual triaxial magnetometers. Conventional scalar-based calibration methods focus solely on fitting the magnitude of the magnetic field vector, lacking control over directional accuracy and thereby compromising the reliability of MGT construction under field conditions. To overcome these limitations, this paper proposes a directionally regularized two-stage calibration framework specifically for cross-shaped MGT fluxgate sensor arrays. A physically interpretable twelve-parameter error model is formulated to decouple sensor-internal distortions from array-level orientation misalignments. Crucially, a directional regularization term is incorporated into the calibration objective function to enforce vector alignment across the array. Furthermore, a high-precision triaxial fluxgate sensor is employed as an internal reference, enabling fully self-contained calibration without external field generators or scalar magnetometers. For accurate estimation of the calibration parameters, a two-stage optimization strategy based on Differential Evolution (DE) is developed, in which all parameters are coarsely estimated via magnitude consistency in the first stage, followed by refined alignment of array orientations via directional regularization in the second stage. Field experiments conducted over six independent trials validate the effectiveness and reproducibility of the proposed framework, yielding an overall mean magnitude RMSE of approximately 5.92 nT and a mean angular deviation of 0.07°. These results confirm that the proposed framework enables accurate and robust compensation of MGT sensor arrays in practical environments.
- 1 January 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 26 (16) , 1
A CMUT-Based Dual-mode Sensor with Wide Range and High Sensitivity for Absolute Pressure Measurement
- 1 January 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 26 (16) , 1
A CMUT-Based Dual-mode Sensor with Wide Range and High Sensitivity for Absolute Pressure Measurement
- 1 January 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 26 (15) , 1
Performance Enhancement Strategies for Resonant Absolute Pressure Sensor
- 1 January 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 26 (15) , 1
Performance Enhancement Strategies for Resonant Absolute Pressure Sensor
- Open Access
- 16 December 2025
- Published by Elsevier in Materials & Design
- Vol. 261
Fabrication technology of capacitive micromachined ultrasonic transducers (CMUTs): A review
- 16 December 2025
- Published by Elsevier in Materials & Design
- Vol. 261
Open AccessFabrication technology of capacitive micromachined ultrasonic transducers (CMUTs): A review
- 2 December 2025
- Published by Elsevier in Journal of Hydrology
- Vol. 665
Improving river surface flow velocity measurement by coupling optimal search line algorithm with space-time image velocimetry
- 2 December 2025
- Published by Elsevier in Journal of Hydrology
- Vol. 665
Improving river surface flow velocity measurement by coupling optimal search line algorithm with space-time image velocimetry
- 1 August 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. PP (1530437X) , 1
In-situ Packaged LiNbO₃ SAW Resonators for Strain and Temperature Sensing under Wide-Range Thermal Conditions
Surface acoustic wave devices have a wide range of application prospects in ultra-low temperature environments. This paper uses COMSOL software simulation to realize the preparation of Y128°LiNiO3 surface acoustic wave resonator (SAWR), and uses silicon oxide wafers to prepare the packaging cap. The in-situ packaged SAWR preparation is completed by adhesive bonding. The tensile strength of the packaged structure can reach 7.49MPa. A normal temperature strain experimental platform and a high and low temperature experimental platform are built to experimentally explore the strain characteristics of the resonator at room temperature and the temperature sensing characteristics of low and high temperatures. The experimental results show that the mounting structure will affect the range of strain sensing, and the in-situ packaged SAWR is not suitable for large strain test environments. In the range of 0 to 1000με, its frequency is basically linear with strain, and the linear sensitivity (SSF) is -161Hz/με, and the strain frequency coefficient (SCF) is 0.49ppm/ε. The in-situ packaged SAWR can work normally at -196°C. Its frequency-temperature relationship in the range of -196°C~-150°C is not completely linear, and there is a high-order temperature sensitivity. The frequency-temperature relationship in the temperature range of -150°C~140°C has a strong linear characteristic, and its linear temperature sensitivity is -26.8kHz/°C. It has good application prospects in wide temperature band wireless passive temperature sensors across zero degrees and normal temperature strain sensing.
- 1 August 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. PP (1530437X) , 1
In-situ Packaged LiNbO₃ SAW Resonators for Strain and Temperature Sensing under Wide-Range Thermal Conditions
Surface acoustic wave devices have a wide range of application prospects in ultra-low temperature environments. This paper uses COMSOL software simulation to realize the preparation of Y128°LiNiO3 surface acoustic wave resonator (SAWR), and uses silicon oxide wafers to prepare the packaging cap. The in-situ packaged SAWR preparation is completed by adhesive bonding. The tensile strength of the packaged structure can reach 7.49MPa. A normal temperature strain experimental platform and a high and low temperature experimental platform are built to experimentally explore the strain characteristics of the resonator at room temperature and the temperature sensing characteristics of low and high temperatures. The experimental results show that the mounting structure will affect the range of strain sensing, and the in-situ packaged SAWR is not suitable for large strain test environments. In the range of 0 to 1000με, its frequency is basically linear with strain, and the linear sensitivity (SSF) is -161Hz/με, and the strain frequency coefficient (SCF) is 0.49ppm/ε. The in-situ packaged SAWR can work normally at -196°C. Its frequency-temperature relationship in the range of -196°C~-150°C is not completely linear, and there is a high-order temperature sensitivity. The frequency-temperature relationship in the temperature range of -150°C~140°C has a strong linear characteristic, and its linear temperature sensitivity is -26.8kHz/°C. It has good application prospects in wide temperature band wireless passive temperature sensors across zero degrees and normal temperature strain sensing.