PAPaul André

Paul André

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Paul André has a total of 8 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Mathematical and Computational Study of Magnetohydrodynamic Flow and Mass Transfer Past a Semi-Infinite Vertical Plate

    by Yves Garnard Irilan, Paul André

    This study presents a comprehensive numerical investigation of transient magnetohydrodynamic (MHD) flow of an electrically conducting, incompressible, and viscous fluid past a semi-infinite vertical plate in the presence of mass transfer and a transverse magnetic field. The interaction between electromagnetic forces and buoyancy-driven flow is analyzed within the framework of unsteady natural convection. The analysis assumes that viscous dissipation and induced magnetic field effects are negligible, which is appropriate for flows characterized by low magnetic Reynolds numbers. The governing conservation equations for momentum, energy, and species concentration are formulated in dimensionless form, resulting in a system of coupled, nonlinear, and time-dependent partial differential equations. To accurately capture the transient behavior and strong coupling between physical variables, an implicit finite difference method is employed. This numerical scheme provides unconditional stability, high computational efficiency, and rapid convergence, making it well suited for simulating complex MHD convection problems. The computational approach allows precise resolution of velocity, temperature, and concentration fields within the boundary layer region. Special attention is given to the influence of buoyancy forces associated with external cooling conditions, corresponding to positive values of the thermal Grashof number (Gr > 0), which characterize free convection regimes where density gradients drive the flow. T

  • Open Access

    Effects of Cold Work and Artificial Aging on Microabrasive Wear of 6201 Aluminum Conductor

    by Paul Andre, Clayton Rovigatti Leiva, José Alexander Araújo, Jorge Luiz de Almeida Ferreira, Cosme Roberto Moreira da Silva

    Aluminum conductor cables are exposed to environmental conditions in service, where wind-induced vibrations generate multiaxial stresses and cause partial sliding between the stranded layers. Such dynamic loading can lead to fatigue or wear failure, particularly at the contact zones between wire layers. The influence of heat treatment and cold work on the wear of these aluminum wires remains unstudied. This work aims to evaluate the microabrasive wear of rolled and heat-treated 6201 aluminum alloy wires used in conductor cables. The wear tests were performed using free-ball microabrasive wear equipment and alumina (Al2O3) abrasive paste at a concentration of 0.40 g/mL of distilled water. The parameters used were as follows: 100 Cr6 steel balls with a diameter of 25.4 mm, sample inclination of 60°, normal force of 0.3 N, and shaft speed of 0.185 m/s or 280 rpm. The test time was set at 20 min, 30 min, 40 min, 50 min, and 60 min. The wear test data were processed using the Achard equation. The microabrasive wear test results indicate that the wear coefficient decreased by 19.1% after the artificial aging process, compared with the solution-treated alloy (95% CI: 15.5–22.3%), and this reduction was statistically significant (p < 0.001). After the combined treatment of rolling and artificial aging, the alloy had a drop in wear coefficient of 36.1% compared to the same solution-treated alloy (95% CI: 32.6–39.6%), representing the largest statistically significant improvement among the tested conditions (p < 0.001). Cold work (rolling) reduces the mobility of dislocations, requiring greater stress to deform the material, thereby increasing its stiffness and wear resistance. In this 6201 alloy, it is inferred that artificial aging led to the formation of Guinier-Preston zones, which evolved into the formation of metastable β” precipitates in needle-like form, coherent with the matrix. As the aging process progresses, the β’ particles evolve into larger β particles that are no longer coherent with the matrix. The combined processes of rolling and aging decrease the wear coefficient. Statistical analysis demonstrated that microstructural conditions explain approximately half of the total variability in the wear coefficient (η2 = 0.495), indicating that the wear performance under the present experimental configuration is primarily governed by intrinsic strengthening mechanisms rather than experimental variability.


  • Open Access

    The Effect of DLC Surface Coatings on Microabrasive Wear of Ti-22Nb-6Zr Obtained by Powder Metallurgy

    by Silvio José Gobbi, Jorge Luiz de Almeida Ferreira, José Alexander Araújo, Paul André, Vinicius André Rodrigues Henriques, Vladimir Jesus Trava Airoldi, Cosme Roberto Moreira da Silva

    Titanium alloys have a high cost of production and exhibit low resistance to abrasive wear. The objective of this work was to carry out diamond-like carbon (DLC) coating, with dissimilar thicknesses, on Ti-22Nb-6Zr titanium alloys produced by powder metallurgy, and to evaluate its microabrasive wear resistance. The samples were compacted, cold pressed, and sintered, producing substrates for coating. The DLC coatings were carried out by PECVD (plasma-enhanced chemical vapor deposition). Free sphere microabrasive wear tests were performed using alumina (Al2O3) abrasive suspension. The DLC-coated samples were characterized by scanning electron microscopy (SEM), Vickers microhardness, coatings adhesion tests, confocal laser microscopy, atomic force microscopy (AFM), and Raman spectroscopy. The coatings did not show peeling-off or delamination in adhesion tests. The PECVD deposition was effective, producing sp2 and sp3 mixed carbon compounds characteristic of diamond-like carbon. The coatings provided good structural quality, homogeneity in surface roughness, excellent coating-to-substrate adhesion, and good tribological performance in microabrasive wear tests. The low wear coefficients obtained in this work demonstrate the excellent potential of DLC coatings to improve the tribological behavior of biocompatible titanium alloy parts (Ti-22Nb-6Zr) produced with a low modulus of elasticity (closer to the bone) and with near net shape, given by powder metallurgy processing.