Anika Sun
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Anika Sun has a total of 11 co-authors. Here are the top co-authors by number of shared publications:
- Alaeddin Burak Irez
Department of Mechanical Engineering, Faculty of Mechanical Engineering Istanbul Technical University (ITU) Istanbul Turkey
3 shared publications - Ashlee S. Liao
Carnegie Mellon University
3 shared publications - Bhavya Chopra
Carnegie Mellon University
3 shared publications - Ji Min Seok
Carnegie Mellon University
3 shared publications - Kevin Dai
Carnegie Mellon University
3 shared publications - Michael J. Bennington
Carnegie Mellon University
3 shared publications
Latest Publications
- Open Access
- 24 March 2026
- Published by Wiley in Journal of Biomechanical Engineering
- Vol. 148 (7) , 1-26
Impacts of Sterilization Method on Material Properties of 3D Printable Resins With Prolonged Exposure to Cell Culture Environments
Low-cost 3D printing has become increasingly important in biomedical research, enabling rapid fabrication of custom cell culture devices, fixtures, and biohybrid robotic components. However, little is known about how common sterilization procedures and prolonged cell culture exposure impact the mechanical properties of commercially available resins. In this study, we analyzed five candidate 3D-printable resins—three rigid (Asiga DentaGUIDE, Liqcreate Bio-Med Clear, and Phrozen AquaGray 8K) and two elastomeric (Asiga DentaGUM and Formlabs Silicone 40A)—to evaluate the effects of ethanol/UV and autoclave sterilization on material properties in phosphate-buffered saline (PBS) at physiological conditions. Using stress–strain data from tensile and compressive mechanical tests, elastic moduli, ultimate tensile strength (UTS), and strain at break were compared across sterilization techniques. Results showed that sterilization significantly altered the mechanical properties of rigid resins, with Phrozen AquaGray 8K and Liqcreate Bio-Med Clear exhibiting large reductions in tensile stiffness and strength, while Asiga DentaGUIDE retained greater stability. In contrast, elastomeric resins were more robust: Asiga DentaGUM and Formlabs Silicone 40A demonstrated minimal or nonsignificant changes across sterilization methods, though post-treatment protocols influenced variability. Notably, several rigid resins also exhibited substantially lower moduli in PBS compared to manufacturer-reported values. These findings emphasize the need for experimental validation of 3D printed resin properties under intended use conditions and suggest that Asiga DentaGUIDE and Formlabs Silicone 40A are promising candidates for biohybrid applications. Overall, this work provides critical guidance for selecting sterilization-compatible materials for biomedical devices and biohybrid robotics.
- 24 March 2026
- Published by Wiley in Journal of Biomechanical Engineering
- Vol. 148 (7) , 1-26
Open AccessImpacts of Sterilization Method on Material Properties of 3D Printable Resins With Prolonged Exposure to Cell Culture Environments
Low-cost 3D printing has become increasingly important in biomedical research, enabling rapid fabrication of custom cell culture devices, fixtures, and biohybrid robotic components. However, little is known about how common sterilization procedures and prolonged cell culture exposure impact the mechanical properties of commercially available resins. In this study, we analyzed five candidate 3D-printable resins—three rigid (Asiga DentaGUIDE, Liqcreate Bio-Med Clear, and Phrozen AquaGray 8K) and two elastomeric (Asiga DentaGUM and Formlabs Silicone 40A)—to evaluate the effects of ethanol/UV and autoclave sterilization on material properties in phosphate-buffered saline (PBS) at physiological conditions. Using stress–strain data from tensile and compressive mechanical tests, elastic moduli, ultimate tensile strength (UTS), and strain at break were compared across sterilization techniques. Results showed that sterilization significantly altered the mechanical properties of rigid resins, with Phrozen AquaGray 8K and Liqcreate Bio-Med Clear exhibiting large reductions in tensile stiffness and strength, while Asiga DentaGUIDE retained greater stability. In contrast, elastomeric resins were more robust: Asiga DentaGUM and Formlabs Silicone 40A demonstrated minimal or nonsignificant changes across sterilization methods, though post-treatment protocols influenced variability. Notably, several rigid resins also exhibited substantially lower moduli in PBS compared to manufacturer-reported values. These findings emphasize the need for experimental validation of 3D printed resin properties under intended use conditions and suggest that Asiga DentaGUIDE and Formlabs Silicone 40A are promising candidates for biohybrid applications. Overall, this work provides critical guidance for selecting sterilization-compatible materials for biomedical devices and biohybrid robotics.
- Open Access
- 13 August 2025
- Published by Springer Nature in Scientific Data
- Vol. 12 (1) , 1416
Cytotoxic and Mechanical Properties of Resins 3D Printed with Low-Cost Hardware for C2C12 Biohybrid Actuators
For biohybrid actuators, the properties of synthetic materials interfacing with living cells are crucial due to cellular chemical and mechanical sensitivities. 3D-printable resins exhibit a wide range of properties, but mechanical properties are frequently reported before sterilization. Additionally, biocompatibility must be assessed for specific use cases, including in the context of the cell type and printing procedures. Therefore, this data descriptor details a new dataset of cytotoxicity and material properties of six commercially-available resins (three rigid and three elastomeric) printed on a Phrozen Sonic Mini 8K and sterilized using 70% ethanol exposure or autoclaving. Experiments were designed to model C2C12-biohybrid conditions. Cytotoxicity analyses were conducted by directly culturing C2C12 with sterilized samples. For material characterization, uniaxial tension and compression tests with post-hoc Hookean and Yeoh models and print fidelity assessments were conducted for nonsterile and sterile samples. The mechanical properties were assessed after submersion in phosphate-buffered saline to mimic conditions in biohybrid applications. Overall, this dataset provided comprehensive testing on cytotoxicity and material properties for 3D-printable resins in C2C12-biohybrid applications.
- 13 August 2025
- Published by Springer Nature in Scientific Data
- Vol. 12 (1) , 1416
Open AccessCytotoxic and Mechanical Properties of Resins 3D Printed with Low-Cost Hardware for C2C12 Biohybrid Actuators
For biohybrid actuators, the properties of synthetic materials interfacing with living cells are crucial due to cellular chemical and mechanical sensitivities. 3D-printable resins exhibit a wide range of properties, but mechanical properties are frequently reported before sterilization. Additionally, biocompatibility must be assessed for specific use cases, including in the context of the cell type and printing procedures. Therefore, this data descriptor details a new dataset of cytotoxicity and material properties of six commercially-available resins (three rigid and three elastomeric) printed on a Phrozen Sonic Mini 8K and sterilized using 70% ethanol exposure or autoclaving. Experiments were designed to model C2C12-biohybrid conditions. Cytotoxicity analyses were conducted by directly culturing C2C12 with sterilized samples. For material characterization, uniaxial tension and compression tests with post-hoc Hookean and Yeoh models and print fidelity assessments were conducted for nonsterile and sterile samples. The mechanical properties were assessed after submersion in phosphate-buffered saline to mimic conditions in biohybrid applications. Overall, this dataset provided comprehensive testing on cytotoxicity and material properties for 3D-printable resins in C2C12-biohybrid applications.
- Open Access
Cytotoxicity and Characterization of 3D-Printable Resins Using a Low-Cost Printer for Muscle-based Biohybrid Devices
Biohybrid devices integrate biological and synthetic materials. The selection of an appropriate synthetic material to interface with living cells and tissues is crucial due to cellular chemical and mechanical sensitivities. As such, the stiffness of the material and its biocompatibility while in direct contact must be considered. In this study, the material properties and biocompatibility of six commercially available, 3D printable resins (three rigid and three elastomeric) were assessed for their suitability for biohybrid actuators. To characterize the material, uniaxial tension and compression tests with post-hoc Hookean and Yeoh model analyses were conducted for both nonsterile and sterilized (ethanol-soaking or autoclaved) samples. The mechanical properties of the elastomeric resins were minimally impacted by the different sterilization techniques. However, both Phrozen AquaGray 8K and Liqcreate Bio-Med Clear rigid resins were significantly softer in tensile tests after sterilization, and AquaGray became far more ductile. Asiga DentaGUIDE was much more stable in its mechanical properties than the other rigid resins. It was also shown that long-term exposure to saline solutions leads to a decrease in the Young’s moduli of these rigid resins before any sterilization has occurred. The print fidelity was also assessed for nonsterile and sterilized samples via manual scoring to determine the impacts of the sterilization processes on the part fidelity. Sterilization techniques had a minimal impact on print fidelity for both elastomeric and ridged resins with two exceptions. In both Formlabs Silicone 40A IPA/BuOAc post-treatment and Phrozen AquaGrey 8K groups, ethanol/UV-sterilization caused more degradation compared to autoclave-sterilization. In addition to the material analyses, cytotoxicity analyses using calcein AM and ethidium homodimer-1 fluorescence markers were conducted by directly culturing C2C12, a common myoblast cell line used in bioactuators, with sterilized resin samples. Of the elastomeric resins, only Formlabs Silicone 40A was shown to have minimal impacts on cell viability. For the rigid resins, Asiga DentaGUIDE, Liqcreate Bio-Med Clear, and ethanol-sterilized Phrozen AquaGray 8K demonstrated minimal impacts on cell viability. Based on these analyses, Asiga DentaGUIDE and Formlabs Silicone 40A demonstrate potential for applications in biohybrid muscle-based actuators when using low-cost 3D printers.
Open AccessCytotoxicity and Characterization of 3D-Printable Resins Using a Low-Cost Printer for Muscle-based Biohybrid Devices
Biohybrid devices integrate biological and synthetic materials. The selection of an appropriate synthetic material to interface with living cells and tissues is crucial due to cellular chemical and mechanical sensitivities. As such, the stiffness of the material and its biocompatibility while in direct contact must be considered. In this study, the material properties and biocompatibility of six commercially available, 3D printable resins (three rigid and three elastomeric) were assessed for their suitability for biohybrid actuators. To characterize the material, uniaxial tension and compression tests with post-hoc Hookean and Yeoh model analyses were conducted for both nonsterile and sterilized (ethanol-soaking or autoclaved) samples. The mechanical properties of the elastomeric resins were minimally impacted by the different sterilization techniques. However, both Phrozen AquaGray 8K and Liqcreate Bio-Med Clear rigid resins were significantly softer in tensile tests after sterilization, and AquaGray became far more ductile. Asiga DentaGUIDE was much more stable in its mechanical properties than the other rigid resins. It was also shown that long-term exposure to saline solutions leads to a decrease in the Young’s moduli of these rigid resins before any sterilization has occurred. The print fidelity was also assessed for nonsterile and sterilized samples via manual scoring to determine the impacts of the sterilization processes on the part fidelity. Sterilization techniques had a minimal impact on print fidelity for both elastomeric and ridged resins with two exceptions. In both Formlabs Silicone 40A IPA/BuOAc post-treatment and Phrozen AquaGrey 8K groups, ethanol/UV-sterilization caused more degradation compared to autoclave-sterilization. In addition to the material analyses, cytotoxicity analyses using calcein AM and ethidium homodimer-1 fluorescence markers were conducted by directly culturing C2C12, a common myoblast cell line used in bioactuators, with sterilized resin samples. Of the elastomeric resins, only Formlabs Silicone 40A was shown to have minimal impacts on cell viability. For the rigid resins, Asiga DentaGUIDE, Liqcreate Bio-Med Clear, and ethanol-sterilized Phrozen AquaGray 8K demonstrated minimal impacts on cell viability. Based on these analyses, Asiga DentaGUIDE and Formlabs Silicone 40A demonstrate potential for applications in biohybrid muscle-based actuators when using low-cost 3D printers.