IAIvica Anic

Ivica Anic

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Ivica Anic has a total of 18 co-authors. Here are the top co-authors by number of shared publications:

  • Anja Baraba

    University of Zagreb School of Dental Medicine, Department of Endodontics and Restorative Dentistry, Gundulićeva 5, 10000 Zagreb, Croatia

    4 shared publications
  • Ivana Miletić

    School of Dental Medicine, University of Zagreb, Gundulićeva 5, 10000 Zagreb, Croatia

    4 shared publications
  • Ana Budimir

    Clinical Department for Clinical Microbiology, Prevention and Control of Infectious Diseases, University Hospital Centre Zagreb, University of Zagreb School of Medicine, Zagreb, Croatia

    1 shared publication
  • Anja Sesar

    Dent Polyclin Zagreb, Dept Endodont Oral Patol & Periodontol, Zagreb, Croatia

    1 shared publication
  • Davor Zeljezic

    Division of Toxicology, Institute for Medical Research and Occupational Health, 10000 Zagreb, Croatia

    1 shared publication
  • Gabrijela Kapetanović Petričević

    Univ Zagreb, Sch Dent Med, Dept Endodont & Restorat Dent, Gunduliceva 5, Zagreb 10000, Croatia

    1 shared publication

Latest Publications

  • Open Access

    Antibacterial Efficacy of Rotary and Reciprocating Instrumentation Techniques

    by Anja Sesar, Ana Budimir, Ivica Anić, Gabrijela Kapetanović Petričević, Ivona Bago

    Objectives: To clinically evaluate the effectiveness of rotary (ProTaper Next [PTN]) and reciprocating (Wave One Gold [WOG]) instrumentation techniques in eliminating bacteria from the root canals of teeth with apical periodontitis during a single-visit root canal treatment. Materials and methods: Forty patients were randomly assigned to the WOG or PTN instrumentation techniques groups. A single- visit root canal treatment was performed on all the patients. In both groups, root canals were irrigated with 10 ml of sodium hypochlorite (NaOCl) and the final irrigation protocol was applied. Microbiological samples from the root canal were collected initially (Sample 1), after chemo-mechanical instrumentation (Sample 2), and after the final irrigation protocol (Sample 3). Quantification of bacteria at each stage of root canal treatment was performed using the culture method (colony-forming units [CFUs]), and bacterial species were identified using MALDI-TOF mass spectrometry. Results: There were 50 aerobic and anaerobic bacterial species identified. Chemo-mechanical root canal treatment with both instrumentation techniques and the final irrigation protocol significantly reduced the number of CFUs (p0.05). Conclusion: Although both root canal instrumentation techniques were highly effective in removing bacteria from the necrotic canals of teeth with chronic apical periodontitis, no complete eradication of bacteria was found in any sample.


  • Influence of Different Pulse Durations of Er:YAG Laser Based on Variable Square Pulse Technology on Microtensile Bond Strength of a Self-Etch Adhesive to Dentin

    by Anja Baraba, Walter Dukić, Nicoletta Chieffi, Marco Ferrari, Ivica Anić, Ivana Miletić

    Objective: The aim of the study was to evaluate the microtensile bond strength of a composite resin to dentin modified with three different pulse durations of the Er:YAG laser based on variable square pulse technology and with one self-etch adhesive. Materials and methods: The entire occlusal enamel was removed to obtain flat dentin surface for 48 human molar teeth. The teeth were randomly divided into four experimental groups ( n =12 per group), according to the pretreatment of dentin: (1) control group; (2) super short pulse (SSP) (50 μsec); (3) medium short pulse (MSP) (100 μsec); and (4) short pulse (SP) (300 μsec) with Er:YAG laser. The energy of the laser used was 80 mJ with average power of 0.8 W. The microtensile bond strength was tested with a universal testing machine. Two specimens from each experimental group were subjected to scanning electron microscopic (SEM) examination, to observe the irradiated surface. Results: Dentin surface treated with SSP showed significantly lower microtensile bond strength values (24±9.8 MPa) in comparison with the control group and SP group (35.3±12.8 and 32.9±10.7 MPa, respectively), ( p 0.05). Conclusions: The use of SP and MSP of the Er:YAG laser with one step self-etch adhesive does not impair or improve the microtensile bond strength in dentin, whereas SSP may not be suitable for dentin surface treatment prior to bonding procedures.


  • Evaluation of cytotoxic and genotoxic effects of two resin-based root-canal sealers and their components on human leucocytes in vitro

    by A. Baraba, D. Želježić, N. Kopjar, M. Mladinić, I. Anić, I. Miletić

    To evaluate the in vitro genotoxicity and cytotoxicity of two resin-based root canal sealers and to determine the type of cell death they induce. The sealers tested were Epiphany and RealSeal. Each component of the material (Epiphany Primer, Epiphany Thinning Resin, Epiphany Sealant, RealSeal Primer, RealSeal Thinning Resin and RealSeal Root Canal Sealant), components in permutual combinations and all components mixed together were tested on human peripheral blood leucocytes using ethidium bromide/acridine orange viability staining and comet assay. Simultaneously, untreated negative control cultures were analysed in the same manner. DNA damage was evaluated following 4 h of treatment and after 24 h in the absence of the components of the materials. After 4 h of treatment, except thinning resin, each individual component and the different combinations of components induced a significant increase in DNA migration ability (P < 0.05). After 24 h, combination of primer, thinning resin and sealant of both materials caused cell death inducing intense apoptosis. After 24 h, cells exposed to Epiphany Sealant and RealSeal Root Canal Sealant, both in polymerized and unpolymerized form, exhibited a level of DNA damage that was similar to the control. Primer and thinning resin of both resin-based root canal sealers and their combinations were cytotoxic and induced apoptosis. Both sealants had no significant effect on the viability of the human leucocytes.


  • Active versus passive microleakage of Resilon/Epiphany and gutta‐percha/AH Plus

    by Lumnije Kqiku, Peter Städtler, Hans Jürgen Gruber, Anja Baraba, Ivica Anic, Ivana Miletic

    The purpose of this in vitro study was to assess the active versus passive dye microleakage and apical sealing ability of laterally condensed gutta‐percha/AH Plus versus Resilon/Epiphany. One hundred and twenty teeth were instrumented and divided into experimental, positive and negative control groups. In group 1, the teeth were obturated with gutta‐percha/AH Plus and in group 2 the teeth were obturated with Resilon/Epiphany. The apical seal was evaluated with a passive and active dye penetration test. Absorbance of the extracted dye was determined with a spectrophotometer. Resilon/Epiphany showed less dye penetration in comparison with the gutta‐percha/AH Plus group (P < 0.05). There were no statistically significant differences between the passive and active dye penetration tests (P > 0.05). In this in vitro study, canals obturated with Resilon/Epiphany showed less apical leakage than those obturated with gutta‐percha/AH Plus, regardless of the type of dye penetration test used.


  • Ablative Potential of the Erbium–Doped Yttrium Aluminium Garnet Laser and Conventional Handpieces: A Comparative Study

    by Anja Baraba, Ivana Miletic, Silvana Jukic Krmek, Tadej Perhavec, Zelimir Bozic, Ivica Anic

    Objectives: To compare the ability of the Variable Square Pulse technology (VSP-technology)–based erbium-doped yttrium aluminium garnet (Er:YAG) laser working in maximum speed (MAX) mode (1000 mJ, 300 μs, 20 Hz) and the high-speed handpiece to ablate enamel, to compare the ability of for the VSP-technology-based Er:YAG laser working in MAX mode and the low-speed handpiece to ablate dentin, and to analyze in vitro effects of Er:YAG ablation of enamel and dentine surfaces using scanning electron microscopy (SEM). Background Data: A VSP-technology-based Er:YAG laser operating in MAX mode should be appropriate for achieving the maximum ablating speed in hard dental tissues. Materials and Methods: The experiment was conducted on extracted, cleaned, sterilized human molar teeth. Cavity preparations were made in hard dental tissues using the VSP-technology Er:YAG laser in MAX mode, in enamel using the high-speed handpiece, and in dentin using the low-speed handpiece at different time intervals. A laser triangulation profilometer was used to determine cavity volumes. The cavity surfaces of five specimens were examined using SEM. Results: The Er:YAG laser removed a volume of enamel that was 3.3 times as large as that removed by the high-speed handpiece in the same period of time. In dentin, the Er:YAG laser removed 8 to 18 times as much volume as the steel bur in the same period of time. The Er:YAG ablation rate in dentin was faster than in enamel. SEM of laser prepared cavities showed a well-defined surface, free of the smear layer. Conclusions: The VSP-technology-based Er:YAG laser, working in MAX mode, is more efficient than mechanical drills for enamel and dentin ablation.