Mykolas Akulauskas
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Mykolas Akulauskas has a total of 21 co-authors. Here are the top co-authors by number of shared publications:
- Vygandas Rutkunas
Professor, Department of Prosthodontics, Institute of Odontology, Faculty of Medicine, Vilnius University, Vilnius, Lithuania
3 shared publications - Darius Jegelevičius
Faculty of Electrical and Electronics Engineering, Biomedical Engineering Institute, Kaunas University of Technology, Kaunas, Lithuania
2 shared publications - Liudas Auškalnis
Department of Prosthodontics, Institute of Odontology, Faculty of Medicine, Vilnius University, Vilnius, Lithuania
2 shared publications - Agne Gedrimiene
Department of Prosthodontics, Institute of Odontology, Faculty of Medicine, Vilnius University, Vilnius, Lithuania
1 shared publication - Aiste Kernen-Gintaute
Department of Prosthetic Dentistry, Center for Dental Medicine, Medical Center - University of Freiburg, Faculty of Medicine, University of Freiburg, Freiburg, Germany
1 shared publication - Andrius Kubilius
Department of Prosthodontics, Institute of Odontology, Faculty of Medicine, Vilnius University, Vilnius, Lithuania
1 shared publication
Latest Publications
- 12 June 2026
- Published by Elsevier in Journal of Dentistry
- Vol. 175, 106802
Accuracy of full-arch digital implant impression and bite registration: effect of different reference object strategies and intraoral scanners
- 12 June 2026
- Published by Elsevier in Journal of Dentistry
- Vol. 175, 106802
Accuracy of full-arch digital implant impression and bite registration: effect of different reference object strategies and intraoral scanners
- 19 June 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 25 (15) , 28518-28528
Quality Evaluation of Intraoral Scanners Using Reverse-Engineered Scan Body
The incorporation of intraoral scanners (IOS) into dental implantology has notably increased the efficiency of clinical workflows. One of the key features of any IOS system is their accuracy, which defines how well scanner digitizes the scanned surfaces. In this study, CARES RC Mono intraoral scan bodies (ISB) extracted from digitized dental arches were used to evaluate the digitization accuracy of one laboratory scanner (E4) and four intraoral scanners (Trios 3, Trios 4, Carestream 3600 and Primescan). The proposed accuracy evaluation method reverse-engineers the surface of the extracted intraoral scan body. It starts by identifying well-defined intraoral scan body surfaces, then creates their respective geometric primitives, and uses them to generate a CAD (computer-aided design) model on top of the scanned surface. Two measurement types were used: the accuracy of the created CAD model and the 3D surface deviation between each defined ISB part and the CAD model. This approach bypasses the conventional fine alignment method in favor of a more elaborate and versatile evaluation algorithm, which can be used to evaluate any cylindrical-shaped ISB. Nine parameters were evaluated for each extracted scan body. Based on these evaluations, E4 demonstrated the best results, followed by Primescan scanner. The remaining scanners showed only minor differences in accuracy between them.
- 19 June 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 25 (15) , 28518-28528
Quality Evaluation of Intraoral Scanners Using Reverse-Engineered Scan Body
The incorporation of intraoral scanners (IOS) into dental implantology has notably increased the efficiency of clinical workflows. One of the key features of any IOS system is their accuracy, which defines how well scanner digitizes the scanned surfaces. In this study, CARES RC Mono intraoral scan bodies (ISB) extracted from digitized dental arches were used to evaluate the digitization accuracy of one laboratory scanner (E4) and four intraoral scanners (Trios 3, Trios 4, Carestream 3600 and Primescan). The proposed accuracy evaluation method reverse-engineers the surface of the extracted intraoral scan body. It starts by identifying well-defined intraoral scan body surfaces, then creates their respective geometric primitives, and uses them to generate a CAD (computer-aided design) model on top of the scanned surface. Two measurement types were used: the accuracy of the created CAD model and the 3D surface deviation between each defined ISB part and the CAD model. This approach bypasses the conventional fine alignment method in favor of a more elaborate and versatile evaluation algorithm, which can be used to evaluate any cylindrical-shaped ISB. Nine parameters were evaluated for each extracted scan body. Based on these evaluations, E4 demonstrated the best results, followed by Primescan scanner. The remaining scanners showed only minor differences in accuracy between them.
- Top Cited PapersOpen Access
- 4 January 2025
- Published by Elsevier in Journal of Dentistry
- Vol. 153, 105559
Accuracy of digital and conventional implant impressions in edentulous jaws: A clinical comparative study
- 4 January 2025
- Published by Elsevier in Journal of Dentistry
- Vol. 153, 105559
Top Cited PapersOpen AccessAccuracy of digital and conventional implant impressions in edentulous jaws: A clinical comparative study
- Open Access
- 1 January 2024
- Published by XMLink in The Journal of Advanced Prosthodontics
- Vol. 16 (5) , 302-310
Effect of reference objects on the accuracy of digital implant impressions in partially edentulous arches
Rutkūnas V, et al. J Adv Prosthodont. 2024 Oct;16(5):302-310. https://doi.org/10.4047/jap.2024.16.5.302
- 1 January 2024
- Published by XMLink in The Journal of Advanced Prosthodontics
- Vol. 16 (5) , 302-310
Open AccessEffect of reference objects on the accuracy of digital implant impressions in partially edentulous arches
Rutkūnas V, et al. J Adv Prosthodont. 2024 Oct;16(5):302-310. https://doi.org/10.4047/jap.2024.16.5.302
- 24 August 2022
- Published by Elsevier in Journal of Dentistry
- Vol. 126, 104267
The effect of different implant impression splinting techniques and time on the dimensional accuracy: An in vitro study
- 24 August 2022
- Published by Elsevier in Journal of Dentistry
- Vol. 126, 104267
The effect of different implant impression splinting techniques and time on the dimensional accuracy: An in vitro study