Rui Fan
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Rui Fan has a total of 10 co-authors. Here are the top co-authors by number of shared publications:
- Fujun Ma
College of Electrical and Information Engineering, Hunan University, Changsha, China
3 shared publications - Gelin Huang
College of Electrical and Information Engineering, Hunan University, Changsha, China
3 shared publications - Junpan Wang
College of Electrical and Information Engineering, Hunan University, Changsha, China
2 shared publications - Qixiang Yang
College of Electrical and Information Engineering, Hunan University, Changsha, China
2 shared publications - Zhengxiao Zhang
College of Electrical and Information Engineering, Hunan University, Changsha, China
2 shared publications - Qiaoling Peng
College of Electrical and Information Engineering, Hunan University, Changsha, China
1 shared publication
Latest Publications
- 4 November 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industrial Electronics
- Vol. 73 (3) , 3883-3894
Hybrid Pulse Density Modulation of T-Type Resonant Inverter for Induction Heating
Pulse density modulation (PDM) is commonly used in induction heating (IH) to enhance inverter efficiency. However, PDM can cause significant fluctuations in the output current, especially under light-load conditions, leading to current intermittency and thereby causing the phase-locked loop to lose lock. Due to the limited output levels of the full-bridge inverters, the PDM improvement schemes applicable to LLC resonant tanks are constrained. To address this issue, an IH topology based on a T-type resonant inverter is proposed in this article. By coordinating the operation of each leg, this topology extends the output levels of the inverter while ensuring soft switching for all power devices. Aiming at the problems of PDM, a hybrid PDM (HPDM) is introduced, which can optimize the pulse sequence distribution and level configuration, effectively reduce current fluctuation amplitude and mitigate current intermittency. Moreover, a reconfigurable LLC-L resonant tank is proposed, utilizing dynamic impedance adjustment to promote more uniform pulse sequence distribution, and further alleviating current fluctuations. The experimental results validate the effectiveness of the proposed method. Compared with PDM, HPDM reduces current ripple by more than half and also improves system efficiency.
- 4 November 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industrial Electronics
- Vol. 73 (3) , 3883-3894
Hybrid Pulse Density Modulation of T-Type Resonant Inverter for Induction Heating
Pulse density modulation (PDM) is commonly used in induction heating (IH) to enhance inverter efficiency. However, PDM can cause significant fluctuations in the output current, especially under light-load conditions, leading to current intermittency and thereby causing the phase-locked loop to lose lock. Due to the limited output levels of the full-bridge inverters, the PDM improvement schemes applicable to LLC resonant tanks are constrained. To address this issue, an IH topology based on a T-type resonant inverter is proposed in this article. By coordinating the operation of each leg, this topology extends the output levels of the inverter while ensuring soft switching for all power devices. Aiming at the problems of PDM, a hybrid PDM (HPDM) is introduced, which can optimize the pulse sequence distribution and level configuration, effectively reduce current fluctuation amplitude and mitigate current intermittency. Moreover, a reconfigurable LLC-L resonant tank is proposed, utilizing dynamic impedance adjustment to promote more uniform pulse sequence distribution, and further alleviating current fluctuations. The experimental results validate the effectiveness of the proposed method. Compared with PDM, HPDM reduces current ripple by more than half and also improves system efficiency.
- 11 June 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 40 (10) , 14881-14893
A Full-Range ZVS Comprehensive Control Strategy for Dual-Port LLLC Induction Heating System
The full-range zero voltage switching (ZVS) comprehensive control strategy is proposed for a high-power dual-port LLLC induction heating system which allows the system to operate efficiently across the entire power range. Under heavy load, a novel dual-phase-shift (DPS) control strategy is proposed in this article. Using time-domain analysis, the minimum circulating current curve and the ZVS range under DPS conditions are derived. The optimal phase-shift angle relationship is determined by combining the minimum circulating current and the full-range ZVS region. However, under DPS control, the minimum output power is one-quarter of its full load capacity due to the lack of internal phase-shift in inverter II. To overcome this limitation, a frequency-doubling pulse frequency modulation (FD-PFM) control strategy is proposed under light load. Frequency-doubling control is implemented through time-division multiplexing between the two inverters, which enables the resonance circuit frequency to be doubled without altering the switching frequency of each inverter. The FD-PFM approach facilitates a faster response to power variation with frequency, enabling the system to adjust power in a narrower frequency range. This enables smooth, wide-range power adjustment across the entire system and ensures ZVS operation across the full power range. A 14 kW prototype was developed, and the experimental results align closely with the theoretical analysis.
- 11 June 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 40 (10) , 14881-14893
A Full-Range ZVS Comprehensive Control Strategy for Dual-Port LLLC Induction Heating System
The full-range zero voltage switching (ZVS) comprehensive control strategy is proposed for a high-power dual-port LLLC induction heating system which allows the system to operate efficiently across the entire power range. Under heavy load, a novel dual-phase-shift (DPS) control strategy is proposed in this article. Using time-domain analysis, the minimum circulating current curve and the ZVS range under DPS conditions are derived. The optimal phase-shift angle relationship is determined by combining the minimum circulating current and the full-range ZVS region. However, under DPS control, the minimum output power is one-quarter of its full load capacity due to the lack of internal phase-shift in inverter II. To overcome this limitation, a frequency-doubling pulse frequency modulation (FD-PFM) control strategy is proposed under light load. Frequency-doubling control is implemented through time-division multiplexing between the two inverters, which enables the resonance circuit frequency to be doubled without altering the switching frequency of each inverter. The FD-PFM approach facilitates a faster response to power variation with frequency, enabling the system to adjust power in a narrower frequency range. This enables smooth, wide-range power adjustment across the entire system and ensures ZVS operation across the full power range. A 14 kW prototype was developed, and the experimental results align closely with the theoretical analysis.
- 5 November 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industrial Electronics
- Vol. 72 (5) , 4933-4942
A Model Predictive Control of Three-Level Cascaded Noninverting Buck–Boost Converter for Energy Storage System
The three-level cascaded noninverting buck–boost converter (TL-CNIBBC) has various operating modes and is especially suited at wide-range voltage bidirectional conversion for energy storage. How to choose a suitable operating mode and realize smooth mode switching is the key problem to be solved. In this article, the operation principle of TL-CNIBBC is analyzed, and two extended modes based on the traditional working modes are introduced to eliminate the dead zone when the input voltage is close to the output voltage. Second, a model predictive control (MPC) with inductor current as a cost function is proposed, taking the hysteresis loop control to avoid mode jumping with mode switching rules defined to achieve multimode smooth transition. Finally, to address the capacitor voltage imbalance in three-level converter, a modification of the duty ratio is proposed. Experimental results show the proposed control strategy can select the proper working modes effectively and realize smooth mode switching.
- 5 November 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industrial Electronics
- Vol. 72 (5) , 4933-4942
A Model Predictive Control of Three-Level Cascaded Noninverting Buck–Boost Converter for Energy Storage System
The three-level cascaded noninverting buck–boost converter (TL-CNIBBC) has various operating modes and is especially suited at wide-range voltage bidirectional conversion for energy storage. How to choose a suitable operating mode and realize smooth mode switching is the key problem to be solved. In this article, the operation principle of TL-CNIBBC is analyzed, and two extended modes based on the traditional working modes are introduced to eliminate the dead zone when the input voltage is close to the output voltage. Second, a model predictive control (MPC) with inductor current as a cost function is proposed, taking the hysteresis loop control to avoid mode jumping with mode switching rules defined to achieve multimode smooth transition. Finally, to address the capacitor voltage imbalance in three-level converter, a modification of the duty ratio is proposed. Experimental results show the proposed control strategy can select the proper working modes effectively and realize smooth mode switching.