CKCandice Kent

Candice Kent

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Candice Kent has a total of 31 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Association of Kidney Biopsy Needle Gauge with Postprocedure Complications and Biopsy Adequacy

    by MaryKate Staunton, Kanika Garg, Sagar Sadarangani, Amrita Makhijani, Kyra Shelton, Emma Koval, Cathleen Liang, Melissa Shaw, Candice Kent, F. Perry Wilson, et al.

    Key Points: Needle selection in kidney biopsy requires balancing risk of complications with benefit of obtaining diagnostic tissue. Our data show that higher needle gauge provides more tissue for diagnosis but might be associated with greater risk of complications. Background: While a larger needle gauge can provide additional kidney tissue for diagnosis, it might also predispose to greater complication risk. Here, we evaluate the safety and diagnostic adequacy of kidney biopsies in patients who underwent a biopsy with various needle sizes. Methods: We evaluated rates of biopsy-related complications and adequacy between participants who underwent biopsy with 16 versus 18 G needles. We assessed safety using a composite outcome of blood transfusion, angiographic intervention, hemoglobin drop of at least 2 g/dl, or at least a medium sized hematoma after kidney biopsy. We defined adequacy as the number of glomeruli available for diagnosis. Results: Among 781 participants included in the analysis, 665 biopsies (85%) were performed using a 16 G needle and 116 (15%) were performed using an 18 G needle. We observed similar odds of complications in the 16 G group as compared with the 18 G group in univariable analysis (odds ratio, 1.56 [95% confidence interval, 0.81 to 3.01]); however, there were higher odds of complications in the 16 G group in both multivariable analysis adjusting for prebiopsy bleeding risk factors (2.40 [1.16 to 4.93]) and propensity score weighted analysis (2.92 [1.28 to 6.67]). As compared with 18 G needle, 16 G biopsy needle was associated with more glomeruli obtained (13 [9–19] versus 11 [6–15], P < 0.001). The higher number of glomeruli in 16 G group persisted after multivariable adjustment (5.06 [2.52 to 7.59]) and propensity score weighted (4.39 [0.37 to 8.42]) analyses. Conclusions: Participants with kidney biopsies performed with a 16 G needle tended to sample more glomeruli and had similar complications on univariable analysis but higher complications when adjusting for prebiopsy risk factors. This indicates that larger needle gauge provided more tissue for diagnosis, but clinicians appropriately avoided its use in those at higher risk of complications. Our findings suggest that the use of a 16 G needle improves diagnostic yield but carries a higher adjusted risk of complications, underscoring the importance of individualized needle gauge selection.


  • Open Access

    Associations between Blood DNA Methylation and Histopathologic Features in Lupus Nephritis

    by Patrick Demkowicz, Ieva Kavaliauskaite, Sophia C. Faulkner, Candice Kent, Melissa Shaw, Deepika Kumar, Joachim H. Ix, F. Perry Wilson, Dennis G. Moledina, Mathieu F. Bakhoum, et al.

    An abstract is unavailable. This article is available as a PDF only.

  • External Validation of an Electronic Health Record–Based Diagnostic Model for Histological Acute Tubulointerstitial Nephritis

    by Dennis G. Moledina, Kyra Shelton, Steven Menez, Abinet M. Aklilu, Yu Yamamoto, Bashar A. Kadhim, Melissa Shaw, Candice Kent, Amrita Makhijani, David Hu, et al.

    Key Points: Individual noninvasive diagnostic tests lack accuracy for diagnosing histological acute tubulointerstitial nephritis. A validated diagnostic model combining four clinical tests accurately predicted acute tubulointerstitial nephritis on biopsy in two separate populations. Background: Accurate diagnosis of acute tubulointerstitial nephritis (AIN) often requires a kidney biopsy. We previously developed a diagnostic statistical model for predicting biopsy-confirmed AIN by combining four laboratory tests after evaluating over 150 potential predictors from the electronic health record. In this study, we validate this diagnostic model in two biopsy-based cohorts at Johns Hopkins Hospital (JHH) and Yale University, which were geographically and temporally distinct from the development cohort, respectively. Methods: We analyzed patients who underwent kidney biopsy at JHH and Yale University (2019–2023). We assessed discrimination (area under receiver-operating characteristics curve [AUC]) and calibration using previously derived model coefficients and recalibrated the model using an intercept correction factor that accounted for differences in baseline prevalence of AIN between development and validation cohorts. Results: We included 1982 participants: 1454 at JHH and 528 at Yale. JHH (5%) and Yale (17%) had lower proportions of biopsies with AIN than the development set (23%). The AUC was 0.73 (95% confidence interval [CI], 0.66 to 0.79) at JHH and 0.73 (95% CI, 0.67 to 0.78) at Yale, similar to the development set (0.73 [95% CI, 0.64 to 0.81]). Calibration was imperfect in validation cohorts, particularly at JHH, but improved with the application of an intercept correction factor. The model increased AUC of clinicians’ prebiopsy suspicion for AIN by 0.10 to 0.77 (95% CI, 0.71 to 0.82). Conclusions: An AIN diagnostic model retained discrimination in two validation cohorts but needed recalibration to account for local AIN prevalence. The model improved clinicians’ ability to predict AIN.