Meryam Beniazza
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Meryam Beniazza has a total of 5 co-authors. Here are the top co-authors by number of shared publications:
- Andrea Corsinotti
Centre for Regenerative Medicine, Institute for Regeneration and Repair, MS Society Edinburgh Centre for MS Research, University of Edinburgh, Edinburgh EH16 4UU, UK
1 shared publication - Anna Williams
UK Dementia Research Institute at The University of Edinburgh, Edinburgh, UK
1 shared publication - David A. D. Munro
UK Dementia Research Institute, University of Edinburgh 4 , Edinburgh
1 shared publication - Josef Priller
Department of Psychiatry and Psychotherapy, Charité – Universitätsmedizin Berlin, Berlin, Germany
1 shared publication - Nadine Bestard-Cuche
Centre for Regenerative Medicine, Institute for Regeneration and Repair, MS Society Edinburgh Centre for MS Research, University of Edinburgh, Edinburgh EH16 4UU, UK
1 shared publication
Latest Publications
- Open Access
Illumina SBS Sequencing and DNBSEQ Perform Similarly for Single-Cell Transcriptomics
Background/Objectives: High-throughput single-cell RNA sequencing (scRNA-seq) workflows produce libraries that demand extensive sequencing. However, standard next-generation sequencing (NGS) methods remain expensive, contributing to the high running costs of single-cell experiments and often negatively affecting the sample numbers and statistical strength of such projects. In recent years, a plethora of new sequencing technologies have become available to researchers through several manufacturers, often providing lower-cost alternatives to standard NGS. Methods: In this study, we compared data generated from mouse scRNA-seq libraries sequenced with both standard Illumina sequencing by synthesis (Illumina SBS) and MGI’s DNA nanoball sequencing (DNBSEQ). Results: Our findings reveal similar overall performance using both technologies. DNBSEQ exhibited mildly superior sequence quality compared to Illumina SBS, as evidenced by higher Phred scores, lower read duplication rates and a greater number of genes mapping to the reference genome. Yet these improvements did not translate into meaningful differences in single-cell analysis parameters in our experiments, including detection of additional genes within cells, gene expression saturation levels and numbers of identified cells, with both technologies demonstrating equally robust performance in these aspects. The data produced by both sequencing platforms also produced comparable analytical outcomes for single-cell analysis. No significant difference in the annotation of cells into different cell types was observed and the same top genes were differentially expressed between populations and experimental conditions. Conclusions: Overall, our data demonstrate that alternative technologies can be applied to sequence scRNA-seq libraries, generating virtually indistinguishable results compared to standard methods, and providing cost-effective alternatives.
Open AccessIllumina SBS Sequencing and DNBSEQ Perform Similarly for Single-Cell Transcriptomics
Background/Objectives: High-throughput single-cell RNA sequencing (scRNA-seq) workflows produce libraries that demand extensive sequencing. However, standard next-generation sequencing (NGS) methods remain expensive, contributing to the high running costs of single-cell experiments and often negatively affecting the sample numbers and statistical strength of such projects. In recent years, a plethora of new sequencing technologies have become available to researchers through several manufacturers, often providing lower-cost alternatives to standard NGS. Methods: In this study, we compared data generated from mouse scRNA-seq libraries sequenced with both standard Illumina sequencing by synthesis (Illumina SBS) and MGI’s DNA nanoball sequencing (DNBSEQ). Results: Our findings reveal similar overall performance using both technologies. DNBSEQ exhibited mildly superior sequence quality compared to Illumina SBS, as evidenced by higher Phred scores, lower read duplication rates and a greater number of genes mapping to the reference genome. Yet these improvements did not translate into meaningful differences in single-cell analysis parameters in our experiments, including detection of additional genes within cells, gene expression saturation levels and numbers of identified cells, with both technologies demonstrating equally robust performance in these aspects. The data produced by both sequencing platforms also produced comparable analytical outcomes for single-cell analysis. No significant difference in the annotation of cells into different cell types was observed and the same top genes were differentially expressed between populations and experimental conditions. Conclusions: Overall, our data demonstrate that alternative technologies can be applied to sequence scRNA-seq libraries, generating virtually indistinguishable results compared to standard methods, and providing cost-effective alternatives.