Shuang Liang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Shuang Liang has a total of 16 co-authors. Here are the top co-authors by number of shared publications:
- Heping Cheng
College of Future Technology Peking University
2 shared publications - Hongchen Jiao
School of Instrumentation and Optoelectronics Engineering, Beihang University, Beijing, China
2 shared publications - Lishuang Feng
School of Instrumentation and Optoelectronic Engineering, Beihang University, Beijing 100191, China
2 shared publications Aimin Wang
Peking Univ, Sch Elect, Beijing 100871, Peoples R China
1 shared publication- Aimin Wang
Beijing Laboratory of Biomedical Imaging, Beijing Municipal Education Commission, Beijing, China
1 shared publication Chaoliang Wei
Nanjing Raygen Hlth, PKU Nanjing Inst Translat Med, Nanjing, Peoples R China
1 shared publication
Latest Publications
- Open Access
- 11 April 2025
- Published by MDPI AG in Biosensors
- Vol. 15 (4) , 243
A Novel Adaptive Independent Component Analysis Method for Multi-Channel Optically Pumped Magnetometers’ Magnetocardiography Signals
With the gradual maturation of optically pumped magnetometer (OPM) technology, the use of OPMs to acquire weak magnetocardiography (MCG) signals has started to gain widespread application. Due to the complexity of magnetic environments, MCG signals are often subject to interference from various unknown sources. Independent component analysis (ICA) is one of the most widely used methods for blind source separation. However, in practical applications, the numbers of retained components and filtering components are often selected manually, relying on subjective experience. This study proposes an adaptive ICA method that estimates the signal-to-noise ratio (SNR) before processing to determine the number of components and selects heartbeat-related components based on their characteristic indicators. The method was validated using phantom experiments and MCG data in a 128-channel OPM-MCG system. In the human subject experiment, the array output SNR reached 31.8 dB, and the processing time was significantly reduced to 1/38 of the original. The proposed method outperformed traditional techniques in terms of its ability to identify artifacts and efficiency in this regard, providing strong support for the broader clinical application of OPM-MCG.
- 11 April 2025
- Published by MDPI AG in Biosensors
- Vol. 15 (4) , 243
Open AccessA Novel Adaptive Independent Component Analysis Method for Multi-Channel Optically Pumped Magnetometers’ Magnetocardiography Signals
With the gradual maturation of optically pumped magnetometer (OPM) technology, the use of OPMs to acquire weak magnetocardiography (MCG) signals has started to gain widespread application. Due to the complexity of magnetic environments, MCG signals are often subject to interference from various unknown sources. Independent component analysis (ICA) is one of the most widely used methods for blind source separation. However, in practical applications, the numbers of retained components and filtering components are often selected manually, relying on subjective experience. This study proposes an adaptive ICA method that estimates the signal-to-noise ratio (SNR) before processing to determine the number of components and selects heartbeat-related components based on their characteristic indicators. The method was validated using phantom experiments and MCG data in a 128-channel OPM-MCG system. In the human subject experiment, the array output SNR reached 31.8 dB, and the processing time was significantly reduced to 1/38 of the original. The proposed method outperformed traditional techniques in terms of its ability to identify artifacts and efficiency in this regard, providing strong support for the broader clinical application of OPM-MCG.
- 16 October 2024
- Published by Elsevier in Measurement
- Vol. 242
Optical pump magnetometers parametric correction method based on three-axis coil arrays
- 16 October 2024
- Published by Elsevier in Measurement
- Vol. 242
Optical pump magnetometers parametric correction method based on three-axis coil arrays