Jennifer Davies
Jennifer Davies has a total of 20 co-authors. Here are the top co-authors by number of shared publications:
- Nicola Swarbrick
Serious Hazards of Transfusion (SHOT), Manchester Blood Centre Manchester UK
2 shared publications - Shruthi Narayan
Serious Hazards of Transfusion (SHOT), Manchester Blood Centre Manchester UK
2 shared publications - Aline Mirrione‐Savin
Corresponding authors
1 shared publication - Barbee Whitaker
Office of Biostatistics and Epidemiology, Center for Biologics Evaluation and Research, US Food and Drug Administration, Silver Spring, MD
1 shared publication - Caroline Bacquet
Etablissement Français du Sang La Plaine St Denis France
1 shared publication - Debbi Poles
Serious Hazards of Transfusion Manchester UK
1 shared publication
Latest Publications
- 6 April 2026
- Published by Wiley in Vox Sanguinis
- Vol. 121 (7) , 1020-1031
Tracing the gaps: A global snapshot
Background and Objectives: Traceability of blood components ensures patient safety, allowing bidirectional tracing of donors and recipients. Records must be kept for defined intervals and stored safely to ensure data integrity. Compliance must be regularly assessed, with clear accountability and actions for deficiencies. All transfusion staff must be trained in traceability to promote safe practices. The global survey aimed to identify the current status of blood components traceability. Materials and Methods: International Society of Blood Transfusion (ISBT) Working Party on Haemovigilance in collaboration with International Haemovigilance Network (IHN) and Serious Hazards of Transfusion (SHOT) conducted a global survey in traceability, built using Online Surveys by Jisc and distributed to the six World Health Organization (WHO) regions. Responses were analysed using Microsoft Excel. Results: There were 212 responses from 43 countries. In 201/212 (95%), a law or regulation for traceability was reported, and in 189/201 (94%) traceability was bidirectional. Retention periods for records were variable, with ≥30 years being the most common (117/195; 60%). The Ministry of Health (118/212; 56%) and/or regulatory bodies (189/212; 89%) were most often the responsible organizations for monitoring traceability. Training in traceability for transfusion staff was reported in 139/212 (66%). In 32/212 (17%), there was at least one recall where a donor or recipient could not be traced. Records stored in computers (28/212; 13%), hard copies (22/212; 10%) or both (132/212; 62%) were reported. Of those with legacy systems (84/160; 53%), 18 stated that these were not safely managed. A haemovigilance system or equivalent was reported in 171/212 (81%) responses. The main challenges identified were unavailability of information technology (139/212; 66%) and staffing issues (137/212; 65%). Conclusion: This survey highlights wide global variation of traceability practices and highlights critical risks requiring urgent action.
- 6 April 2026
- Published by Wiley in Vox Sanguinis
- Vol. 121 (7) , 1020-1031
Tracing the gaps: A global snapshot
Background and Objectives: Traceability of blood components ensures patient safety, allowing bidirectional tracing of donors and recipients. Records must be kept for defined intervals and stored safely to ensure data integrity. Compliance must be regularly assessed, with clear accountability and actions for deficiencies. All transfusion staff must be trained in traceability to promote safe practices. The global survey aimed to identify the current status of blood components traceability. Materials and Methods: International Society of Blood Transfusion (ISBT) Working Party on Haemovigilance in collaboration with International Haemovigilance Network (IHN) and Serious Hazards of Transfusion (SHOT) conducted a global survey in traceability, built using Online Surveys by Jisc and distributed to the six World Health Organization (WHO) regions. Responses were analysed using Microsoft Excel. Results: There were 212 responses from 43 countries. In 201/212 (95%), a law or regulation for traceability was reported, and in 189/201 (94%) traceability was bidirectional. Retention periods for records were variable, with ≥30 years being the most common (117/195; 60%). The Ministry of Health (118/212; 56%) and/or regulatory bodies (189/212; 89%) were most often the responsible organizations for monitoring traceability. Training in traceability for transfusion staff was reported in 139/212 (66%). In 32/212 (17%), there was at least one recall where a donor or recipient could not be traced. Records stored in computers (28/212; 13%), hard copies (22/212; 10%) or both (132/212; 62%) were reported. Of those with legacy systems (84/160; 53%), 18 stated that these were not safely managed. A haemovigilance system or equivalent was reported in 171/212 (81%) responses. The main challenges identified were unavailability of information technology (139/212; 66%) and staffing issues (137/212; 65%). Conclusion: This survey highlights wide global variation of traceability practices and highlights critical risks requiring urgent action.
- 30 October 2024
- Published by Wiley in British Journal of Haematology
- Vol. 206 (2) , 726-734
Frequencies and causes of ABO‐incompatible red cell transfusions in France, Germany and the United Kingdom
Summary: Prevention of ABO‐incompatible red cell transfusions (ABO‐it) requires accurate donor and patient identification and correct application of processes for transfusion safety. In France and Germany, a bedside identity check and ABO compatibility test are performed. In the UK, an identity check, often structured as a bedside checklist, is performed with or without electronic patient identification (ePID). To compare the efficacy of ABO‐it bedside preventive measures, frequencies and causes of ABO‐it between 2013 and 2022 were investigated in all three countries. Despite differing bedside safety measures, similar average ABO‐it frequencies were observed in France (0.19 [SD:0.09]/100 000 issued red cell units) and in the UK (0.28 [SD:0.17]/100 000), whereas a higher frequency (0.71 [SD:0.23]/100 000) was observed in Germany which has similar bedside safety measures to France. ABO‐it resulted mostly from erroneous patient identification and transfusion of a red cell unit intended for another patient. In France and Germany, all ABO‐it were associated with incorrectly performed identity check and ABO compatibility test. In the UK, most ABO‐it were associated with incorrectly performed identity checks. Current measures to prevent ABO‐it are not fully effective. Further development and implementation of effective patient identification systems, including electronic information systems, across the entire transfusion process, should be considered.
- 30 October 2024
- Published by Wiley in British Journal of Haematology
- Vol. 206 (2) , 726-734
Frequencies and causes of ABO‐incompatible red cell transfusions in France, Germany and the United Kingdom
Summary: Prevention of ABO‐incompatible red cell transfusions (ABO‐it) requires accurate donor and patient identification and correct application of processes for transfusion safety. In France and Germany, a bedside identity check and ABO compatibility test are performed. In the UK, an identity check, often structured as a bedside checklist, is performed with or without electronic patient identification (ePID). To compare the efficacy of ABO‐it bedside preventive measures, frequencies and causes of ABO‐it between 2013 and 2022 were investigated in all three countries. Despite differing bedside safety measures, similar average ABO‐it frequencies were observed in France (0.19 [SD:0.09]/100 000 issued red cell units) and in the UK (0.28 [SD:0.17]/100 000), whereas a higher frequency (0.71 [SD:0.23]/100 000) was observed in Germany which has similar bedside safety measures to France. ABO‐it resulted mostly from erroneous patient identification and transfusion of a red cell unit intended for another patient. In France and Germany, all ABO‐it were associated with incorrectly performed identity check and ABO compatibility test. In the UK, most ABO‐it were associated with incorrectly performed identity checks. Current measures to prevent ABO‐it are not fully effective. Further development and implementation of effective patient identification systems, including electronic information systems, across the entire transfusion process, should be considered.