Delia Francesca Sansico
Delia Francesca Sansico has a total of 20 co-authors. Here are the top co-authors by number of shared publications:
- Lorenzo Drago
UOC Clinical Pathology Laboratory with Specialized Areas, IRCCS MultiMedica, 20138 Milan, Italy
4 shared publications - Michela Salvatici
UOC Laboratory of Clinical Medicine with Specialized Areas, IRCCS MultiMedica, 20138 Milan, Italy
4 shared publications - Monica Gaimarri
UOC Laboratory of Clinical Medicine with Specialized Areas, IRCCS MultiMedica Hospital, 20138 Milan, Italy
3 shared publications - Barbara Bianchi
UOC Laboratory of Clinical Medicine with Specialized Areas, IRCCS MultiMedica Hospital, 20138 Milan, Italy
2 shared publications - Chiara Corrado
UOC Laboratory of Clinical Medicine with Specialized Areas, IRCCS MultiMedica Hospital, 20138 Milan, Italy
2 shared publications - Francesca Rispoli
UOC Laboratory of Clinical Medicine with Specialized Areas, IRCCS MultiMedica, 20138 Milan, Italy
2 shared publications
Latest Publications
- Open Access
- 12 August 2026
- Published by MDPI AG in Biomedicines
- Vol. 14 (8) , 1815
Real-World Evaluation of ANA Testing Pathways: Serological Incompleteness and Comparison of Stepwise Versus Upfront Parallel Reflex Strategies
Background/Objectives: Antinuclear antibody testing by indirect immunofluorescence on HEp-2 cells (ANA-IIF) remains the reference test for systemic autoimmune rheumatic diseases (SARD). However, complete serological characterization requires integration with extractable nuclear antigen (ENA) screening, antigen-specific solid-phase assays (SPA), and confirmatory indirect immunofluorescence (IIF) tests. This study aimed to: (1) quantify real-world serological pathway incompleteness in ANA testing performed outside a structured reflex strategy; (2) compare simulated stepwise and upfront parallel reflex approaches in terms of serological yield, laboratory workload, and costs. Methods: We retrospectively analyzed 2207 consecutive patients referred for ANA-IIF testing between July 2025 and April 2026. Serological incompleteness was defined as non-completion of the predefined Regione Lombardia reflex framework. A fully characterized subgroup of 514 patients, defined by complete reflex-serological assessment, was used to compare a stepwise strategy, in which ANA-IIF positivity triggered downstream testing, with an upfront parallel strategy, in which ANA-IIF, ENA screening, and anti-double-stranded DNA (anti-dsDNA) testing were performed upfront. Results: ANA-IIF was positive in 913/2207 patients (41.4%). Overall, 508 patients (23.0%) had at least one missing follow-up assay expected under the reflex framework. In the fully characterized subgroup, the upfront parallel strategy increased the number of patients with at least one fully characterized autoantibody finding from 15 to 22 (+1.4%), but required 657 additional tests and an estimated incremental cost of approximately €2592. Conclusions: ANA-IIF testing outside a structured reflex pathway frequently resulted in incomplete serological assessment. Although the upfront parallel strategy increased serological yield, it required substantially greater laboratory workload and costs than the stepwise approach. Further studies are needed to define the optimal balance between serological yield, clinical relevance, and cost-effectiveness.
- 12 August 2026
- Published by MDPI AG in Biomedicines
- Vol. 14 (8) , 1815
Open AccessReal-World Evaluation of ANA Testing Pathways: Serological Incompleteness and Comparison of Stepwise Versus Upfront Parallel Reflex Strategies
Background/Objectives: Antinuclear antibody testing by indirect immunofluorescence on HEp-2 cells (ANA-IIF) remains the reference test for systemic autoimmune rheumatic diseases (SARD). However, complete serological characterization requires integration with extractable nuclear antigen (ENA) screening, antigen-specific solid-phase assays (SPA), and confirmatory indirect immunofluorescence (IIF) tests. This study aimed to: (1) quantify real-world serological pathway incompleteness in ANA testing performed outside a structured reflex strategy; (2) compare simulated stepwise and upfront parallel reflex approaches in terms of serological yield, laboratory workload, and costs. Methods: We retrospectively analyzed 2207 consecutive patients referred for ANA-IIF testing between July 2025 and April 2026. Serological incompleteness was defined as non-completion of the predefined Regione Lombardia reflex framework. A fully characterized subgroup of 514 patients, defined by complete reflex-serological assessment, was used to compare a stepwise strategy, in which ANA-IIF positivity triggered downstream testing, with an upfront parallel strategy, in which ANA-IIF, ENA screening, and anti-double-stranded DNA (anti-dsDNA) testing were performed upfront. Results: ANA-IIF was positive in 913/2207 patients (41.4%). Overall, 508 patients (23.0%) had at least one missing follow-up assay expected under the reflex framework. In the fully characterized subgroup, the upfront parallel strategy increased the number of patients with at least one fully characterized autoantibody finding from 15 to 22 (+1.4%), but required 657 additional tests and an estimated incremental cost of approximately €2592. Conclusions: ANA-IIF testing outside a structured reflex pathway frequently resulted in incomplete serological assessment. Although the upfront parallel strategy increased serological yield, it required substantially greater laboratory workload and costs than the stepwise approach. Further studies are needed to define the optimal balance between serological yield, clinical relevance, and cost-effectiveness.
- Open Access
- 22 January 2026
- Published by MDPI AG in International Journal of Molecular Sciences
- Vol. 27 (2) , 1117
Clinical Impact of Macrotroponin on Immunometric Troponin Assays: A Cross-Analytical Case Evaluation
High-sensitivity cardiac troponin assays are susceptible to analytical interferences, including macrotroponin, an immunoglobulin-bound complex that may cause persistent, non-dynamic, and assay-dependent elevations. This paper describes the case of a 74-year-old woman with hypertension who presented with intermittent mild chest discomfort and exertional dyspnea and exhibited persistently elevated but stable cardiac troponin I concentrations over several months, in the absence of clinical, electrocardiographic, or imaging evidence of myocardial injury. Orthogonal testing revealed discordant results across different assay platforms, and polyethylene-glycol (PEG) precipitation resulted in a substantial signal reduction, confirming macrotroponin as the source of assay-dependent analytical interference. Recognizing this phenomenon is crucial to avoid misdiagnosis, unnecessary diagnostic procedures and inappropriate management in patients with isolated troponin elevation. In conclusion, this report provides evidence-based recommendations on the optimal diagnostic strategies and laboratory approaches to adopt in cases of suspected macrotroponin-mediated interference in high-sensitivity cardiac troponin assays.
- 22 January 2026
- Published by MDPI AG in International Journal of Molecular Sciences
- Vol. 27 (2) , 1117
Open AccessClinical Impact of Macrotroponin on Immunometric Troponin Assays: A Cross-Analytical Case Evaluation
High-sensitivity cardiac troponin assays are susceptible to analytical interferences, including macrotroponin, an immunoglobulin-bound complex that may cause persistent, non-dynamic, and assay-dependent elevations. This paper describes the case of a 74-year-old woman with hypertension who presented with intermittent mild chest discomfort and exertional dyspnea and exhibited persistently elevated but stable cardiac troponin I concentrations over several months, in the absence of clinical, electrocardiographic, or imaging evidence of myocardial injury. Orthogonal testing revealed discordant results across different assay platforms, and polyethylene-glycol (PEG) precipitation resulted in a substantial signal reduction, confirming macrotroponin as the source of assay-dependent analytical interference. Recognizing this phenomenon is crucial to avoid misdiagnosis, unnecessary diagnostic procedures and inappropriate management in patients with isolated troponin elevation. In conclusion, this report provides evidence-based recommendations on the optimal diagnostic strategies and laboratory approaches to adopt in cases of suspected macrotroponin-mediated interference in high-sensitivity cardiac troponin assays.
- Open Access
- 1 May 2025
- Published by MDPI AG in International Journal of Molecular Sciences
- Vol. 26 (9) , 4308
Assessment of Plasma and Cerebrospinal Fluid Biomarkers in Patients with Alzheimer’s Disease and Other Dementias: A Center-Based Study
Neuropsychological interviews and neuroimaging techniques are traditional diagnostic methods for Alzheimer’s disease (AD). However, the development of blood-based biomarkers, such as Amyloid beta (Aβ), phosphorylated Tau (pTau), and their ratios, offers promising non-invasive alternatives for early AD detection. This study aimed to analyze the correlation between CSF and plasma biomarkers (Aβ40, Aβ42, Aβ42/Aβ40, pTau181) and evaluate their diagnostic performance in 51 patients with cognitive impairments. Biomarkers were analyzed in both plasma and CSF using an automated chemiluminescence enzyme immunoassay, Lumipulse (Fujirebio). The results showed significant positive correlations between CSF and plasma levels of Aβ42, the Aβ42/Aβ40 ratio, and pTau181, but not for Aβ40. Plasma Aβ42, pTau181, Aβ42/Aβ40 ratio, and pTau181/Aβ42 ratio demonstrated significant differences between patients A+ vs. A− classified based on CSF Amyloid status, as well as between those classified as A+T+ and A−T− according to both CSF Amyloid and Tau levels. Plasma pTau181, Aβ42/Aβ40, and pTau181/Aβ42 ratio showed high diagnostic accuracy in distinguishing A+ from A− (AUC = 0.93–0.95) and A+T+ from A−T− patients (AUC = 0.93–0.97). These findings suggest that plasma biomarkers can effectively differentiate between AD and other forms of dementia, and serve as a reliable, non-invasive tool for early detection and monitoring of Alzheimer’s disease.
- 1 May 2025
- Published by MDPI AG in International Journal of Molecular Sciences
- Vol. 26 (9) , 4308
Open AccessAssessment of Plasma and Cerebrospinal Fluid Biomarkers in Patients with Alzheimer’s Disease and Other Dementias: A Center-Based Study
Neuropsychological interviews and neuroimaging techniques are traditional diagnostic methods for Alzheimer’s disease (AD). However, the development of blood-based biomarkers, such as Amyloid beta (Aβ), phosphorylated Tau (pTau), and their ratios, offers promising non-invasive alternatives for early AD detection. This study aimed to analyze the correlation between CSF and plasma biomarkers (Aβ40, Aβ42, Aβ42/Aβ40, pTau181) and evaluate their diagnostic performance in 51 patients with cognitive impairments. Biomarkers were analyzed in both plasma and CSF using an automated chemiluminescence enzyme immunoassay, Lumipulse (Fujirebio). The results showed significant positive correlations between CSF and plasma levels of Aβ42, the Aβ42/Aβ40 ratio, and pTau181, but not for Aβ40. Plasma Aβ42, pTau181, Aβ42/Aβ40 ratio, and pTau181/Aβ42 ratio demonstrated significant differences between patients A+ vs. A− classified based on CSF Amyloid status, as well as between those classified as A+T+ and A−T− according to both CSF Amyloid and Tau levels. Plasma pTau181, Aβ42/Aβ40, and pTau181/Aβ42 ratio showed high diagnostic accuracy in distinguishing A+ from A− (AUC = 0.93–0.95) and A+T+ from A−T− patients (AUC = 0.93–0.97). These findings suggest that plasma biomarkers can effectively differentiate between AD and other forms of dementia, and serve as a reliable, non-invasive tool for early detection and monitoring of Alzheimer’s disease.
- Open Access
- 6 November 2024
- Published by MDPI AG in International Journal of Molecular Sciences
- Vol. 25 (22) , 11937
Troponin Test, Not Only a Number: An Unusual Case of False Positive
Heterophile antibodies, which can arise from infections, autoimmune disorders, or exposure to animal antigens, can interfere with immunoassays. These antibodies can cross-react with the test reagents used in troponin assays, causing a false elevation in troponin levels. The paper describes a case of a 37-year-old male drug abuser admitted to the emergency room with chest pain. A series of troponin measurements performed using different assays gave discrepant results. Only thanks to the use of Scantibodies HBT tubes, which remove heterophile antibodies, was it possible to make a correct diagnosis of troponin negativity. In conclusion, a correct laboratory/clinical approach to the identification of heterophile antibody interference is essential for accurate troponin testing in order to avoid false positive results. Implementing neutralizing tests can significantly improve the reliability of these diagnostic assays, ensuring better patient outcome.
- 6 November 2024
- Published by MDPI AG in International Journal of Molecular Sciences
- Vol. 25 (22) , 11937
Open AccessTroponin Test, Not Only a Number: An Unusual Case of False Positive
Heterophile antibodies, which can arise from infections, autoimmune disorders, or exposure to animal antigens, can interfere with immunoassays. These antibodies can cross-react with the test reagents used in troponin assays, causing a false elevation in troponin levels. The paper describes a case of a 37-year-old male drug abuser admitted to the emergency room with chest pain. A series of troponin measurements performed using different assays gave discrepant results. Only thanks to the use of Scantibodies HBT tubes, which remove heterophile antibodies, was it possible to make a correct diagnosis of troponin negativity. In conclusion, a correct laboratory/clinical approach to the identification of heterophile antibody interference is essential for accurate troponin testing in order to avoid false positive results. Implementing neutralizing tests can significantly improve the reliability of these diagnostic assays, ensuring better patient outcome.