LJLawrence C. Johnson

Lawrence C. Johnson

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Lawrence C. Johnson has a total of 27 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Performance of Atrial Fibrillation Burden Trends for Stroke Risk Stratification

    by Jonathan P. Piccini, Evan J. Stanelle, Cody C. Johnson, Elaine M. Hylek, Rahul Kanwar, Dhanunjaya R. Lakkireddy, Suneet Mittal, James Peacock, Andrea M. Russo, Dana Soderlund, et al.

    BACKGROUND: Atrial fibrillation (AF) is associated with an increased risk of stroke, yet the limitations of conventional monitoring have restricted our understanding of AF burden risk thresholds. Predictive algorithms incorporating continuous AF burden measures may be useful for predicting stroke. This study evaluated the performance of temporal AF burden trends as predictors of stroke from a large cohort with insertable cardiac monitors. METHODS: Using deidentified data from Optum Clinformatics Data Mart (2007–2019) linked with the Medtronic CareLink insertable cardiac monitor database, we identified patients with an insertable cardiac monitor for AF management (n=1197), suspected AF (n=1611), and cryptogenic stroke (n=2205). Daily AF burden was transformed into simple moving averages, and temporal AF burden trends were defined as the comparison of unique simple moving average pairs. Classification trees were used to predict ischemic stroke, and AF burden significance was quantified using bootstrapped mean variable importance. RESULTS: Of 5013 patients (age, 69.2±11.7 years; 50% male; CHA 2 DS 2 -VASc, 3.7±1.9) who met inclusion criteria, 869 had an ischemic stroke over 2 409 437 days total follow-up. Prior stroke or transient ischemic attack (variable importance, 13.13) was the number 1 predictor of future stroke followed by no prior diagnosis of AF (7.35) and AF burden trends in follow-up (2.59). Temporal proximity of AF and risk of stroke differed by device indication (simple moving averages: AF management, <8 days and suspected AF and cryptogenic stroke, 8–21 days). Together, baseline characteristics and AF burden trends performed optimally for the area under the receiver operating characteristic curve (0.73), specificity (0.70), and relative risk (5.00). CONCLUSIONS: AF burden trends may provide incremental prognostic value as leading indicators of stroke risk compared with conventional schemes.


  • Open Access

    Using Atrial Fibrillation Burden Trends and Machine Learning to Predict Near-Term Risk of Cardiovascular Hospitalization

    by James Peacock, Evan J. Stanelle, Lawrence C. Johnson, Elaine M. Hylek, Rahul Kanwar, Dhanunjaya R. Lakkireddy, Suneet Mittal, Rod S. Passman, Andrea M. Russo, Dana Soderlund, et al.

    BACKGROUND: Atrial fibrillation is associated with an increased risk of cardiovascular hospitalization (CVH), which may be triggered by changes in daily burden. Machine learning of dynamic trends in atrial fibrillation burden, as measured by insertable cardiac monitors (ICMs), may be useful in predicting near-term CVH. METHODS: Using Optum’s deidentified Clinformatics Data Mart Database (2007–2019), linked with the Medtronic CareLink ICM database, we identified patients with >1 days of ICM-detected atrial fibrillation. ICM-detected diagnostic parameters were transformed into simple moving averages over different periods for daily follow-up. A diagnostic trend was defined as the comparison of 2 simple moving averages of different periods for each diagnostic parameter. CVH was defined as any hospital, emergency department, or ambulatory surgical center encounter with a cardiovascular diagnosis-related group or diagnosis code. Machine learning was used to determine which diagnostic trends could best predict patient risk 5 days before CVH. RESULTS: A total of 2616 patients with ICMs met the inclusion criteria (71±11 years; 55% male). Among them, 1998 (76%) had a planned or unplanned CVH over 605 363 days. Machine learning revealed distinct groups: (A) sinus rhythm (reference), (B) below-average burden, (C) above-average burden, and (D) above-average burden with decreasing patient activity. The relative risk was increased in all groups versus the reference (B, 4.49 [95% CI, 3.74–5.40]; C, 8.41 [95% CI, 7.00–10.11]; D, 11.15 [95% CI, 9.10–13.65]), including a 21% increase in CVH detection over prespecified burden thresholds of duration (≥1 hour) and quantity (≥5%). The area under the receiver operating characteristic curve increased from 0.55 when using hourly burden amounts to 0.66 when using burden trends and decreasing patient activity ( P <0.001), a 20% increase in predictive power. CONCLUSIONS: Trends in atrial fibrillation were strongly associated with near-term CVH, especially above-average burden coupled with low patient activity. This approach could provide actionable information to guide treatment and reduce CVH.


  • Open Access

    Use of continuous cardiac monitoring to assess the influence of atrial fibrillation burden and patterns on patient symptoms and healthcare utilization: The DEFINE AFib study

    by Dhanunjaya R. Lakkireddy, Andrea M. Russo, Elaine M. Hylek, Suneet Mittal, James Peacock, Mellanie True Hills, Evan J. Stanelle, Jeffrey D. Lande, Noreli C. Franco, Lawrence C. Johnson, et al.


  • Open Access

    Syncope Recurrence and Downstream Diagnostic Testing after Insertable Cardiac Monitor Placement for Syncope

    by Camille G. Frazier-Mills, Lawrence C. Johnson, Ying Xia, Sarah C. Rosemas, Noreli C. Franco, Sean D. Pokorney

    Despite advances in syncope evaluation strategies and risk stratification, the high cost of syncope is largely driven by extensive and often repetitive testing. This analysis of a large deidentified US claims database compared the use of diagnostic tests, therapeutic procedures, and the recurrence rate of acute syncope events before and after placement of an insertable cardiac monitor (ICM) in syncope patients. The patients had a minimum of 1 year of continuous enrollment before and 2 years after ICM placement. Among 2140 patients identified, a statistically significant reduction in the use of 14 out of 18 tests was observed during follow-up compared with pre-ICM testing. During the 2-year follow-up, 28.3% of patients underwent cardiac therapeutic interventions after a median of 127 days. Significantly fewer patients experienced acute syncope events during the 1st and 2nd years of ICM follow-up compared with the 1-year pre-ICM period, and the frequency of events per patient also decreased. In conclusion, reductions in diagnostic testing and acute syncope events were observed after ICM placement in a large real-world cohort of unexplained syncope patients. Further studies are needed to prospectively assess the impact of ICM vs. short-term monitoring on patient outcomes and healthcare utilization.