Shuai Wu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Shuai Wu has a total of 10 co-authors. Here are the top co-authors by number of shared publications:
- Hui Feng
School of Physical Sciences, University of Science and Technology of China, Hefei, CHINA
6 shared publications Yuanhao Du
4 shared publicationsDeyue An
2 shared publications- Hongmin Ruan
School of Physical Sciences, University of Science and Technology of China, Hefei, CHINA
1 shared publication Lian Zhu
School of Intelligent Manufacturing and Automotive, Anhui Business and Technology College, Hefei, China
1 shared publicationXing Kong
China Tobacco Anhui Industrial Co., Ltd., Hefei, China
1 shared publication
Latest Publications
- 16 February 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Antennas and Wireless Propagation Letters
- Vol. 25 (4) , 1817-1821
High-Efficiency, Low-Cost, Wideband AFTSAs for W-Band and D-Band High-Resolution Imaging
This letter presents a W-band antipodal Fermi tapered slot antenna (AFTSA) with 37.8% relative bandwidth and introduces a novel antipodal fin-line waveguide-to-microstrip transition for feeding. Featuring a lightweight design, each AFTSA weighs only 0.23 g. The transition achieves a return loss better than 15.7 dB and an insertion loss below 0.63 dB. Measurements of five AFTSAs fed by this transition show efficiencies exceeding 80% at most frequency points, with gains ranging from 15 to 20 dB across the W-band. At the target frequency of 100 GHz, the gain is approximately 18.7 dB, the efficiency reaches 88%, and the half-power beamwidths are 1–3° wider than the simulated values of 17.0°/22.8° (E/H). The measurements show favorable agreement with the simulations. Additionally, an array of eight AFTSAs is integrated on a single RO3003 substrate, and a D-band AFTSA design is also presented.
- 16 February 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Antennas and Wireless Propagation Letters
- Vol. 25 (4) , 1817-1821
High-Efficiency, Low-Cost, Wideband AFTSAs for W-Band and D-Band High-Resolution Imaging
This letter presents a W-band antipodal Fermi tapered slot antenna (AFTSA) with 37.8% relative bandwidth and introduces a novel antipodal fin-line waveguide-to-microstrip transition for feeding. Featuring a lightweight design, each AFTSA weighs only 0.23 g. The transition achieves a return loss better than 15.7 dB and an insertion loss below 0.63 dB. Measurements of five AFTSAs fed by this transition show efficiencies exceeding 80% at most frequency points, with gains ranging from 15 to 20 dB across the W-band. At the target frequency of 100 GHz, the gain is approximately 18.7 dB, the efficiency reaches 88%, and the half-power beamwidths are 1–3° wider than the simulated values of 17.0°/22.8° (E/H). The measurements show favorable agreement with the simulations. Additionally, an array of eight AFTSAs is integrated on a single RO3003 substrate, and a D-band AFTSA design is also presented.
- 6 December 2025
- Published by Elsevier in Infrared Physics & Technology
- Vol. 153
Non-destructive thickness testing of TBCs using synthetic aperture imaging with pulsed terahertz waves
- 6 December 2025
- Published by Elsevier in Infrared Physics & Technology
- Vol. 153
Non-destructive thickness testing of TBCs using synthetic aperture imaging with pulsed terahertz waves
- 15 November 2025
- Published by Springer Nature in Applied Physics B
- Vol. 131 (12) , 228
Terahertz ISAR non-destructive testing technology based on THz-TDS with fast reconstruction
- 15 November 2025
- Published by Springer Nature in Applied Physics B
- Vol. 131 (12) , 228
Terahertz ISAR non-destructive testing technology based on THz-TDS with fast reconstruction
- 27 August 2025
- Published by Taylor & Francis in Nondestructive Testing and Evaluation
- Vol. 41 (9) , 1-19
Non-destructive thickness measurement of thermal barrier coatings by Terahertz three-dimensional synthetic aperture imaging method
- 27 August 2025
- Published by Taylor & Francis in Nondestructive Testing and Evaluation
- Vol. 41 (9) , 1-19
Non-destructive thickness measurement of thermal barrier coatings by Terahertz three-dimensional synthetic aperture imaging method
- 8 November 2024
- Published by Springer Nature in Applied Physics B
- Vol. 130 (12) , 1-8
Synthetic aperture imaging with pulsed terahertz waves and its application in three-dimensional modeling of complex structures
- 8 November 2024
- Published by Springer Nature in Applied Physics B
- Vol. 130 (12) , 1-8
Synthetic aperture imaging with pulsed terahertz waves and its application in three-dimensional modeling of complex structures
- 21 October 2024
- Published by Optica Publishing Group in Optics Express
- Vol. 32 (23) , 40190-40201
Cylindrical aperture three-dimensional synthetic aperture imaging with pulsed terahertz waves
In this paper, we report a three-dimensional synthetic aperture imaging method with pulsed terahertz waves realized by a terahertz time-domain spectrometer. In contrast to synthetic aperture imaging systems operating at microwave or millimeter-wave frequencies where the frequency of the transmitter is scanned in the frequency domain, in our imaging system, all the frequency components are contained in a single terahertz pulse that can be generated and detected by photoconductive antennas. The image algorithm was analyzed theoretically and confirmed numerically using the finite-difference time-domain method. A key with plentiful detailed structures was used as the object to be imaged to demonstrate the three-dimensional imaging capabilities of this method. The resolution of the imaging system is 0.3 mm for the linear dimension and 0.1 mm for the circular dimension, as tested by the experimental setup. Finally, an optically opaque plastic pen with and without the cartridge was imaged, and the shape and location of the cartridge could be observed from the reconstructed three-dimensional terahertz images, demonstrating the non-destructive evaluation capabilities of this imaging method. Benefiting from the improvements in the experimental setup in this study, the imaging speed was significantly improved compared with that of the step-by-step scanning method commonly used in terahertz imaging systems with a single transmitter/receiver pair. This imaging method avoids the image degradation caused by specular reflections in active quasi-optical focal plane imaging and the lack of semiconductor devices working at several THz frequencies for synthetic aperture imaging, and may be used for non-destructive evaluation of objects with complex surfaces and internal structures.
- 21 October 2024
- Published by Optica Publishing Group in Optics Express
- Vol. 32 (23) , 40190-40201
Cylindrical aperture three-dimensional synthetic aperture imaging with pulsed terahertz waves
In this paper, we report a three-dimensional synthetic aperture imaging method with pulsed terahertz waves realized by a terahertz time-domain spectrometer. In contrast to synthetic aperture imaging systems operating at microwave or millimeter-wave frequencies where the frequency of the transmitter is scanned in the frequency domain, in our imaging system, all the frequency components are contained in a single terahertz pulse that can be generated and detected by photoconductive antennas. The image algorithm was analyzed theoretically and confirmed numerically using the finite-difference time-domain method. A key with plentiful detailed structures was used as the object to be imaged to demonstrate the three-dimensional imaging capabilities of this method. The resolution of the imaging system is 0.3 mm for the linear dimension and 0.1 mm for the circular dimension, as tested by the experimental setup. Finally, an optically opaque plastic pen with and without the cartridge was imaged, and the shape and location of the cartridge could be observed from the reconstructed three-dimensional terahertz images, demonstrating the non-destructive evaluation capabilities of this imaging method. Benefiting from the improvements in the experimental setup in this study, the imaging speed was significantly improved compared with that of the step-by-step scanning method commonly used in terahertz imaging systems with a single transmitter/receiver pair. This imaging method avoids the image degradation caused by specular reflections in active quasi-optical focal plane imaging and the lack of semiconductor devices working at several THz frequencies for synthetic aperture imaging, and may be used for non-destructive evaluation of objects with complex surfaces and internal structures.