QLQing Liu

Qing Liu

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Qing Liu has a total of 33 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Temperature‐Dependent Spectral and Electrical Characteristics of THz Metasurfaces Integrated With Patterned GaN Thin Films

    by Lanju Liang, Xin Yan, Qing Liu, Zhenhua Li, Haiyun Yao, Ziqun Wang, Xiaofei Hu, Yan Xu, Tigang Ning, Li Pei

    Terahertz (THz) metasurfaces offer strong electromagnetic modulation, yet efficient thermal tunability remains challenging. Here, we investigate the heating‐dependent THz response of metasurfaces integrated with strip‐patterned, square‐patterned, and continuous GaN thin films. The strip‐patterned and continuous samples were characterized from 33°C to 172°C, whereas the square‐patterned sample was measured from 33°C to 130°C. Within the common comparison range up to 130°C, the strip‐patterned configuration exhibited the strongest overall transmittance modulation. These results indicate that GaN pattern geometry modifies the effective electromagnetic loading and interaction with localized resonant fields. When heating was extended to 172°C, the strip‐patterned metasurface exhibited the largest resonance transmittance contrast variation of 11.12%, a phase‐shift range from −334° to 8°, and a maximum transmittance modulation depth of 49.15%. These findings demonstrate semiconductor patterning as an effective strategy for enhancing thermally driven THz modulation.


  • A graphene oxide enhanced terahertz metamaterial for ultra-sensitive detection of d -aspartic acid solution

    by Ji Qi, Pibin Bing, Lanju Liang, Xin Yan, Haiyun Yao, Zhenhua Li, Ziqun Wang, Zhongyang Li, Qing Liu, Guifang Wu

    Graphene oxide enhances the THz electromagnetic response and promotes THz transmission, while immobilizing target biomolecules via chemical bonding. Polyimide capillaries enable solution concentration detection in the THz wave range.


  • LSPR-enhanced terahertz metasensors for highly sensitive CRP detection via antibody functionalizations

    by Manyi Wan, Zhongyang Li, Zhiliang Chen, Lanju Liang, Xin Yan, Haiyun Yao, Zhenhua Li, Ziqun Wang, Xiaofei Hu, Zhaoqing Sun, et al.

    C-reactive protein (CRP) is a biomarker that significantly elevates in cancer patients. Its detection with high sensitivity and specificity is of paramount importance for the early diagnosis and screening of cancer. In this study, we proposed and experimentally demonstrated a CRP antibody-functionalized metasurface biosensor with a simplified metallic design, enabling high-sensitivity detection of CRP using terahertz time-domain spectroscopy. Colloidal gold nanoparticles enhance the sensitivity and quantitative detection capabilities of the biosensor by leveraging the local surface plasmon resonance (LSPR) effect and the enhanced biomolecular recognition. Moreover, the addition of a high concentration of CRP antibodies improves the antigen capture efficiency, thereby further boosting the sensor’s performance. In this study, the designed biosensor was used to measure varying concentrations of CRP and two different types of antigens. By analyzing the sensor’s response variations under different antigen-binding conditions, the specificity of its CRP recognition was validated. Experimental results demonstrated that the sensor exhibited a limit of detection as low as 100 pg/mL, with robust discriminatory capacity between target antigens and nonspecific molecular interference, ensuring exceptional selectivity in detection. This result further confirms the exceptional performance of the metasurface biosensor in precise biomolecular detection, providing crucial technological support for achieving efficient and accurate early cancer screening.


  • An advanced terahertz gallium nitride metasensor for enhanced molecular absorption spectrum analysis of analytes

    by Qing Liu, Tigang Ning, Jing Li, Zhouyi Hu, Lanju Liang, Haiyun Yao, Xin Yan, Yongzhen Chen, Qingyi Wang, Shanghui Guan

    Terahertz (THz) metasensing is an effective method for identifying biological substances, offering advantages such as high efficiency and non-destructiveness. Currently, one important approach to achieving THz fingerprint spectrum sensing is the design of metasensors with broad spectral coverage and multiple resonant peaks. However, there is still potential for further enhancement in the sensitivity, selectivity, and detection limits. Gallium nitride (GaN), with its exceptional optoelectronic properties such as high carrier concentration and conductivity, can be integrated with THz metasensors to create high-performance biosensors. In this study, we propose a THz metasensor coated with GaN. Since different analytes exhibit distinct absorption characteristics in the THz range, preliminary identification of various substances can be achieved by analyzing differences in the trends of spectral changes. Experimental results demonstrate that the proposed metasensor achieves a detection limit of 1 μg mL−1 for bovine serum albumin (BSA) and 10 pg mL−1 for creatinine. Through radar chart analysis, the transmission spectra of the metasensor show significant differences when detecting creatinine and BSA, indicating its capability to effectively identify different analytes. The GaN-metasensor developed in this study provides a highly sensitive and broadly spectrally covered solution for THz molecular spectrum analysis, which holds potential applications in assessing kidney function and health status.


  • Q-BIC THz Metasurface Biosensor Based on Flexible Polyimide for Solution Detection

    by Qing Liu, Tigang Ning, Li Pei, Jing Li, Lanju Liang, Xin Yan, Haiyun Yao, Ziqun Wang, Zhenhua Li, Xiaofei Hu

    The concept of quasi-bound states in the continuum (Q-BIC) in continuous media has garnered significant attention in fields such as sensing and optical switching. Benefiting from localized electric field enhancement, researchers can use the combination of Q-BIC and metasurfaces (MSs) to enable highly efficient and reliable sensing solutions. This article presents a Q-BIC terahertz (THz) MS biosensor integrated with a flexible polyimide (PI) capillary for concentration detection of liquid analytes. The introduction of the PI capillary effectively controls the intensity of THz wave absorption by liquids, successfully addressing the limitations of THz waves in liquid detection. The unique feature of the proposed biosensor lies in its ability to identify the concentrations of ovalbumin and hydrolyzed whey protein in the range of 1 pg/mL to 1 mg/mL by monitoring changes in modulation depth. This approach achieves excellent linear fitting, ensuring robust quantitative analysis. The sensor also demonstrates the ability to detect variations in ethanol solutions. A series of 2-D wavelet coefficient intensity maps (WCIMs) based on continuous wavelet transform (CWT) was constructed, offering a novel approach for identifying solution concentrations. The proposed sensing platform provides several advantages, including higher sensitivity and reusability. This innovative method opens new avenues for liquid-based THz biosensing.


  • Terahertz Metasurface Multidimensional Biosensor Based on Quasi-Bound States in the Continuum for Trace Analyte Detection

    by Qing Liu, Ti Gang Ning, Jing Li, Jing Jing Zheng, Lan Ju Liang, Xin Yan, Hai Yun Yao, Zi Qun Wang, Zhen Hua Li, Xiao Fei Hu

    The integration of terahertz (THz) technology with metasurfaces (MSs) has opened new horizons for the development of highly sensitive biosensors. In this study, we present a novel THz symmetry-protected bound states in the continuum (SP-BIC) MS-based biosensor designed to detect trace biomolecules. Added silver nanoparticles (AgNPs) can interact with THz waves to achieve local electric field enhancement, which enhances the interaction between THz waves and analytes, thereby improving the detection ability of MS sensor. The results of experiment showed that the MS sensor with added AgNps achieved a frequency shift of 35.61 GHz when detecting taurine at a concentration of 111.12 ng/mL and a transmission change of 14.96% when detecting taurine at a concentration of 1.12 ng/mL. The limit of detection (LOD) of the MS sensor is as low as 20 pg/mL. The MS sensor proposed in this paper features a simple structure, convenient detection, and high sensitivity, which can detect biomacromolecules and small biomolecules and demonstrate potential application value in the field of THz biological detection.