Hannah Siems
Hannah Siems has a total of 25 co-authors. Here are the top co-authors by number of shared publications:
- Ariana Peck
Biohub, Redwood City, USA
2 shared publications - Bridget Carragher
Simons Electron Microscopy Center, New York Structural Biology Center
2 shared publications - Clinton S. Potter
Simons Electron Microscopy Center, New York Structural Biology Center
2 shared publications - Daniel Serwas
Chan Zuckerberg Institute for Advanced Biological Imaging
2 shared publications - Dari Kimanius
Biohub, Redwood City, USA
2 shared publications - David A. Agard
University of California San Francisco, Biochemistry and Biophysics, San Francisco, CA
2 shared publications
Latest Publications
- Open Access
AreTomoLive: Automated reconstruction of comprehensively-corrected and denoised cryo-electron tomograms in real-time and at high throughput
A high throughput processing pipeline that performs comprehensive corrections is needed to realize the full potential of cryo-electron tomography and subtomogram averaging. The field’s fragmented software landscape remains a significant hurdle to this end. Here we present AreTomoLive, an automated real-time pipeline composed of two GPU-accelerated packages. The first, AreTomo3, streamlines tomographic alignment and reconstruction, with new features to fully account for sample geometry, locally correct the contrast transfer function, and curate data for downstream tasks. The second package, DenoisET, is a new implementation of the machine learning algorithm Noise2Noise and runs in parallel with AreTomo3 to perform contrast enhancement. To reduce barriers to routine use, AreTomoLive prioritizes automation: AreTomo3 autonomously pauses and reactivates processing depending on the status of data collection, while DenoisET algorithmically determines when to transition from training to inference. AreTomoLive endeavors to advance cryoET for in situ structural analysis with its comprehensive corrections and full automation.
Open AccessAreTomoLive: Automated reconstruction of comprehensively-corrected and denoised cryo-electron tomograms in real-time and at high throughput
A high throughput processing pipeline that performs comprehensive corrections is needed to realize the full potential of cryo-electron tomography and subtomogram averaging. The field’s fragmented software landscape remains a significant hurdle to this end. Here we present AreTomoLive, an automated real-time pipeline composed of two GPU-accelerated packages. The first, AreTomo3, streamlines tomographic alignment and reconstruction, with new features to fully account for sample geometry, locally correct the contrast transfer function, and curate data for downstream tasks. The second package, DenoisET, is a new implementation of the machine learning algorithm Noise2Noise and runs in parallel with AreTomo3 to perform contrast enhancement. To reduce barriers to routine use, AreTomoLive prioritizes automation: AreTomo3 autonomously pauses and reactivates processing depending on the status of data collection, while DenoisET algorithmically determines when to transition from training to inference. AreTomoLive endeavors to advance cryoET for in situ structural analysis with its comprehensive corrections and full automation.
- Open Access
Annotating CryoET Volumes: A Machine Learning Challenge
Cryo-electron tomography (cryoET) has emerged as a powerful structural biology tool for understanding protein complexes in their native cellular environments. Presently, 3D volumes of cellular environments can be acquired in the thousands in a few days where each volume provides a rich and complex cellular landscape. Despite numerous innovations, localizing and identifying the vast majority of protein species in these volumes remains prohibitively difficult. Machine learning based methods provide an opportunity to automate the process of labeling and annotating cryoET volumes. Due to current bottlenecks in the annotation process, and a lack of large standardized datasets, training datasets for machine learning algorithms have been scarce. Here, we present a defined “phantom” sample, along with “ground truth” annotations, that will be the basis of a machine learning challenge to bring cryoET and ML experts together and spur creativity to address this annotation problem. We have also set up a cryoET data portal that provides additional diverse sets of annotated 3D volumes from cryoET experts across the world for the machine learning challenge.
Open AccessAnnotating CryoET Volumes: A Machine Learning Challenge
Cryo-electron tomography (cryoET) has emerged as a powerful structural biology tool for understanding protein complexes in their native cellular environments. Presently, 3D volumes of cellular environments can be acquired in the thousands in a few days where each volume provides a rich and complex cellular landscape. Despite numerous innovations, localizing and identifying the vast majority of protein species in these volumes remains prohibitively difficult. Machine learning based methods provide an opportunity to automate the process of labeling and annotating cryoET volumes. Due to current bottlenecks in the annotation process, and a lack of large standardized datasets, training datasets for machine learning algorithms have been scarce. Here, we present a defined “phantom” sample, along with “ground truth” annotations, that will be the basis of a machine learning challenge to bring cryoET and ML experts together and spur creativity to address this annotation problem. We have also set up a cryoET data portal that provides additional diverse sets of annotated 3D volumes from cryoET experts across the world for the machine learning challenge.