Hong Wu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Hong Wu has a total of 14 co-authors. Here are the top co-authors by number of shared publications:
- Yue Wang
School of Electrical Engineering, Xian Jiaotong University, Xian, China
5 shared publications - Yi Liu
Xi'an Jiaotong University
3 shared publications - Yonghui Liu
Xi'an Jiaotong University
3 shared publications - Yufei Li
State Key Laboratory of Electrical Insulation and Power Equipment, Xian Jiaotong University, Xian, China
3 shared publications Yi Liu
2 shared publicationsBole Feng
Guangzhou Panyu Power Supply Bureau of Guangdong Power Grid Company Ltd., Guangzhou, China
1 shared publication
Latest Publications
- 3 January 2026
- Published by Elsevier in Electric Power Systems Research
- Vol. 254
Open-circuit faults of IGBTs in clamp double submodule-modular multilevel converters: Characterization and diagnosis
- 3 January 2026
- Published by Elsevier in Electric Power Systems Research
- Vol. 254
Open-circuit faults of IGBTs in clamp double submodule-modular multilevel converters: Characterization and diagnosis
- 31 December 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 41 (6) , 9544-9566
A Dual-Perspective Analysis of IGBT Open-Circuit Faults in Hybrid Modular Multilevel Converters: Unified Characteristics and Diagnoses
The hybrid modular multilevel converter (HMMC) comprising both full-bridge submodules (SMs) and half-bridge SMs has drawn extensive attention for its cost-effective dc fault ride-through capability. However, insulated gate bipolar transistor (IGBT) open-circuit fault (OCF) diagnosis—a prerequisite for fault isolation and fault reconfiguration—is critical to the reliability of HMMCs, while relevant research remains scarce. Furthermore, varied OCF scenarios within HMMC further complicate fault diagnosis. To fill this gap, this article first conducts a dual-perspective analysis of IGBT OCFs in HMMCs, covering single and multiple OCF scenarios in an SM. Two unified characteristics are yielded: first, Unified Characteristic I, derived from the mode-type perspective, reveals that IGBT OCFs cause specific mode-type conversions of the faulty SM, and second, Unified Characteristic II, derived from the switching-function perspective, indicates that the faulty SM maintains a specific switching function. Therefore, a unified characteristics-driven strategy is proposed, including a detection stage and a localization stage. In the detection stage, the suspected faulty SM is selected via Unified Characteristic II and its status is then ascertained using Unified Characteristic I. Upon the identification of a fault, other suspected faulty SMs are screened, with their statuses determined in the ensuing localization stage. Hardware-in-the-loop experiments validate the effectiveness of the proposed strategy.
- 31 December 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 41 (6) , 9544-9566
A Dual-Perspective Analysis of IGBT Open-Circuit Faults in Hybrid Modular Multilevel Converters: Unified Characteristics and Diagnoses
The hybrid modular multilevel converter (HMMC) comprising both full-bridge submodules (SMs) and half-bridge SMs has drawn extensive attention for its cost-effective dc fault ride-through capability. However, insulated gate bipolar transistor (IGBT) open-circuit fault (OCF) diagnosis—a prerequisite for fault isolation and fault reconfiguration—is critical to the reliability of HMMCs, while relevant research remains scarce. Furthermore, varied OCF scenarios within HMMC further complicate fault diagnosis. To fill this gap, this article first conducts a dual-perspective analysis of IGBT OCFs in HMMCs, covering single and multiple OCF scenarios in an SM. Two unified characteristics are yielded: first, Unified Characteristic I, derived from the mode-type perspective, reveals that IGBT OCFs cause specific mode-type conversions of the faulty SM, and second, Unified Characteristic II, derived from the switching-function perspective, indicates that the faulty SM maintains a specific switching function. Therefore, a unified characteristics-driven strategy is proposed, including a detection stage and a localization stage. In the detection stage, the suspected faulty SM is selected via Unified Characteristic II and its status is then ascertained using Unified Characteristic I. Upon the identification of a fault, other suspected faulty SMs are screened, with their statuses determined in the ensuing localization stage. Hardware-in-the-loop experiments validate the effectiveness of the proposed strategy.
- 14 February 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industry Applications
- Vol. 61 (3) , 4388-4401
Impedance Modeling and Mechanism Analysis of Low-Frequency Oscillation in Vehicle-Grid Coupling System Under the Mixed Operation of Locomotives
The mixed operation of locomotives aggravates the interaction between locomotives and the traction network, resulting in the low-frequency oscillation (LFO) for the vehicle-grid coupling system. However, the mechanism of the LFO when different types of locomotives access the traction network needs to be elucidated. In addition, the impact of parameters of locomotives on the system stability is still unclear. To solve the above problems, this paper firstly proposes a circuit model-based conversion method to implement the conversion from multiple-input multiple-output (MIMO) admittance models to single-input single-output (SISO) impedance models of locomotives in the single-phase stationary frame. Secondly, the concepts of dominant negative resistance and dominant phase margin (DPM) are proposed to correctly reveal the mechanism of the LFO and accurately reflect the stability margin of the system, respectively. Then, the impact of parameters on the system stability is quantitatively evaluated for the first time based on the sensitivity index and the variation pattern of DPM. Accordingly, the parameter-tuning criteria are proposed to further improve the system stability and thus increase the number of locomotives that can access the traction network. Finally, the correctness of the theoretical analysis is verified through comprehensive simulation results and hardware-in-the-loop (HIL) experiments.
- 14 February 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industry Applications
- Vol. 61 (3) , 4388-4401
Impedance Modeling and Mechanism Analysis of Low-Frequency Oscillation in Vehicle-Grid Coupling System Under the Mixed Operation of Locomotives
The mixed operation of locomotives aggravates the interaction between locomotives and the traction network, resulting in the low-frequency oscillation (LFO) for the vehicle-grid coupling system. However, the mechanism of the LFO when different types of locomotives access the traction network needs to be elucidated. In addition, the impact of parameters of locomotives on the system stability is still unclear. To solve the above problems, this paper firstly proposes a circuit model-based conversion method to implement the conversion from multiple-input multiple-output (MIMO) admittance models to single-input single-output (SISO) impedance models of locomotives in the single-phase stationary frame. Secondly, the concepts of dominant negative resistance and dominant phase margin (DPM) are proposed to correctly reveal the mechanism of the LFO and accurately reflect the stability margin of the system, respectively. Then, the impact of parameters on the system stability is quantitatively evaluated for the first time based on the sensitivity index and the variation pattern of DPM. Accordingly, the parameter-tuning criteria are proposed to further improve the system stability and thus increase the number of locomotives that can access the traction network. Finally, the correctness of the theoretical analysis is verified through comprehensive simulation results and hardware-in-the-loop (HIL) experiments.
- 6 November 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 40 (2) , 3578-3599
An Improved Switching Method-Based Diagnostic Strategy for IGBT Open-Circuit Faults in Hybrid Modular Multilevel Converters
The hybrid modular multilevel converter (HMMC) has attracted extensive attention due to its dc fault ride-through capability. However, the research on its insulated gate bipolar transistor (IGBT) open-circuit fault (OCF) diagnosis is still barely seen, which becomes a research gap that may jeopardize the reliability of the HMMC system. To address this issue, this article first proposes an improved switching method, which can ensure all six types of IGBT OCFs unveil their fault characteristics thoroughly by using an extra bypassed switching sequence. Furthermore, the improved switching method remains the same switching loss as the existing switching method. Afterward, a diagnostic method is brought forward to identify the faulty SM by its fixed specific sequence in a period of time while the switching sequences of other SMs with the same type are dynamic. On this basis, an improved switching method-based diagnostic strategy that consists of various types of diagnostic methods is proposed, which can diagnose all six types of IGBT OCFs in the HMMC within 20 ms and have immunity to dc faults and load change. Experimental results in a hardware-in-the-loop platform verify the effectiveness of the proposed switching method and diagnostic strategy.
- 6 November 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 40 (2) , 3578-3599
An Improved Switching Method-Based Diagnostic Strategy for IGBT Open-Circuit Faults in Hybrid Modular Multilevel Converters
The hybrid modular multilevel converter (HMMC) has attracted extensive attention due to its dc fault ride-through capability. However, the research on its insulated gate bipolar transistor (IGBT) open-circuit fault (OCF) diagnosis is still barely seen, which becomes a research gap that may jeopardize the reliability of the HMMC system. To address this issue, this article first proposes an improved switching method, which can ensure all six types of IGBT OCFs unveil their fault characteristics thoroughly by using an extra bypassed switching sequence. Furthermore, the improved switching method remains the same switching loss as the existing switching method. Afterward, a diagnostic method is brought forward to identify the faulty SM by its fixed specific sequence in a period of time while the switching sequences of other SMs with the same type are dynamic. On this basis, an improved switching method-based diagnostic strategy that consists of various types of diagnostic methods is proposed, which can diagnose all six types of IGBT OCFs in the HMMC within 20 ms and have immunity to dc faults and load change. Experimental results in a hardware-in-the-loop platform verify the effectiveness of the proposed switching method and diagnostic strategy.