Shuo Han
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Shuo Han has a total of 20 co-authors. Here are the top co-authors by number of shared publications:
- Bahareh Morovati
University of Massachusetts Lowell
9 shared publications - Hengyong Yu
University of Massachusetts Lowell
9 shared publications - Li Zhou
University of Massachusetts Lowell
9 shared publications Shuyi Fan
University of Massachusetts Lowell
6 shared publications- Yu Shi
University of Massachusetts Lowell
6 shared publications - Changsheng Fang
University of Massachusetts Lowell
5 shared publications
Latest Publications
- 1 October 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Medical Imaging
- Vol. 45 (10) , 4923-4936
WDK-Net: Lightweight Wavelet Diffusion With Kolmogorov--Arnold Network for Limited-Angle Cardiac CT Reconstruction
Limited-angle cardiac CT reconstruction is a severely ill-posed problem, where incomplete angular coverage leads to strong artifacts and structural distortions. Although diffusion-based methods have shown strong potential for improving reconstruction quality, their high computational cost, large memory demand, and slow inference remain major barriers to practical clinical deployment. To address this bottleneck, we propose WDK-Net, a lightweight dual-domain reconstruction framework with a structure-detail decoupled design, aiming to make diffusion-based reconstruction more computationally feasible for cardiac CT. Leveraging wavelet transforms, WDK-Net models global structures and local details in different domains. Specifically, although shallow low-frequency components preserve more complete anatomical structures, deeper decomposition provides a more compact low-frequency representation for efficient generative modeling. Experiments on simulated, in-house clinical, and public cardiac CT datasets demonstrate that the proposed method achieves competitive or superior reconstruction quality across multiple limited-angle settings (60°, 90°, 120°), while substantially reducing the computational burden compared with existing diffusion-based reconstruction methods. These results suggest that frequency-selective low-dimensional wavelet diffusion, combined with explicit structure-detail decoupling, provides a feasible pathway toward more efficient and clinically deployable diffusion-based limited-angle cardiac CT reconstruction.
- 1 October 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Medical Imaging
- Vol. 45 (10) , 4923-4936
WDK-Net: Lightweight Wavelet Diffusion With Kolmogorov--Arnold Network for Limited-Angle Cardiac CT Reconstruction
Limited-angle cardiac CT reconstruction is a severely ill-posed problem, where incomplete angular coverage leads to strong artifacts and structural distortions. Although diffusion-based methods have shown strong potential for improving reconstruction quality, their high computational cost, large memory demand, and slow inference remain major barriers to practical clinical deployment. To address this bottleneck, we propose WDK-Net, a lightweight dual-domain reconstruction framework with a structure-detail decoupled design, aiming to make diffusion-based reconstruction more computationally feasible for cardiac CT. Leveraging wavelet transforms, WDK-Net models global structures and local details in different domains. Specifically, although shallow low-frequency components preserve more complete anatomical structures, deeper decomposition provides a more compact low-frequency representation for efficient generative modeling. Experiments on simulated, in-house clinical, and public cardiac CT datasets demonstrate that the proposed method achieves competitive or superior reconstruction quality across multiple limited-angle settings (60°, 90°, 120°), while substantially reducing the computational burden compared with existing diffusion-based reconstruction methods. These results suggest that frequency-selective low-dimensional wavelet diffusion, combined with explicit structure-detail decoupling, provides a feasible pathway toward more efficient and clinically deployable diffusion-based limited-angle cardiac CT reconstruction.
- 1 September 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Radiation and Plasma Medical Sciences
- Vol. 10 (7) , 1088-1098
Accelerated Physics-Guided Diffusion Model for 3-D Limited-Angle Reconstruction of Cardiac Computed Tomography
Cardiovascular diseases (CVDs) remain the leading cause of morbidity and mortality worldwide. Computed tomography (CT) plays an important role in the diagnosis and management of CVDs. However, the temporal resolution of current cardiac CT imaging techniques is still insufficient to freeze the beating heart. One solution to improve temporal resolution is fast data acquisition for a limited-angle range. Unfortunately, this approach introduces significant limited-angle artifacts that compromise image quality. Diffusion models have shown promising results to address this issue by effectively reconstructing missing data, but the process is typically time-consuming. In this paper, we propose a novel method for 3D limited-angle reconstruction using a diffusion model, optimized to significantly reduce computational time. Specifically, our approach integrates the regularized derivative least square (RDLS) algorithm with denoising diffusion implicit models. The numerical simulations and clinical data experiments demonstrate that the proposed model outperforms the existing methods both quantitatively and qualitatively. Compared with DDS, our method delivers a 1.8× speedup on the simulated dataset and a 3.4× speedup on the real clinical dataset.
- 1 September 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Radiation and Plasma Medical Sciences
- Vol. 10 (7) , 1088-1098
Accelerated Physics-Guided Diffusion Model for 3-D Limited-Angle Reconstruction of Cardiac Computed Tomography
Cardiovascular diseases (CVDs) remain the leading cause of morbidity and mortality worldwide. Computed tomography (CT) plays an important role in the diagnosis and management of CVDs. However, the temporal resolution of current cardiac CT imaging techniques is still insufficient to freeze the beating heart. One solution to improve temporal resolution is fast data acquisition for a limited-angle range. Unfortunately, this approach introduces significant limited-angle artifacts that compromise image quality. Diffusion models have shown promising results to address this issue by effectively reconstructing missing data, but the process is typically time-consuming. In this paper, we propose a novel method for 3D limited-angle reconstruction using a diffusion model, optimized to significantly reduce computational time. Specifically, our approach integrates the regularized derivative least square (RDLS) algorithm with denoising diffusion implicit models. The numerical simulations and clinical data experiments demonstrate that the proposed model outperforms the existing methods both quantitatively and qualitatively. Compared with DDS, our method delivers a 1.8× speedup on the simulated dataset and a 3.4× speedup on the real clinical dataset.
- 23 March 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Radiation and Plasma Medical Sciences
- Vol. PP (24697311) , 1
STABLE-PCCT: A Spectral Transformer Architecture with Bayesian Learning and Edge Preservation for Photon-Counting CT Image Reconstruction
Photon-counting computed tomography (PCCT) provides energy-resolved imaging with high spectral resolution, enabling advanced material decomposition and tissue characterization. However, photon starvation and spectral distortion, especially in low-dose settings, introduce severe noise and cross-channel artifacts, significantly degrading image quality. To address these challenges, we propose a Spectral Transformer Architecture with Bayesian Learning and Edge Preservation for PCCT (STABLE-PCCT). It is a novel deep learning framework that integrates depthwise separable convolutions (DSConv), squeeze-and-excitation (SE) blocks, and a residual Transformer module as a learned prior for Bayesian reconstruction. Each spectral channel is independently processed through lightweight convolutional encoders and SE modules to extract fine spatial features and enhance channel-specific saliency. The resulting feature representations are fused and refined using a Transformer block by modeling global intra-channel dependencies and contextual relationships. A fully connected layer path generates a high-fidelity spectral output. Additionally, anisotropic diffusion filtering (ADF) is applied in the image domain to suppress noise while preserving edges and texture details. Experimental results on simulated and real extremity MARS PCCT datasets demonstrate that STABLE-PCCT outperforms the state-of-the-art baselines in preserving anatomical structures, reducing noise, and improving spectral fidelity. The proposed framework offers an efficient and scalable solution for denoising and reconstruction in low-dose PCCT and other spectral imaging applications.
- 23 March 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Radiation and Plasma Medical Sciences
- Vol. PP (24697311) , 1
STABLE-PCCT: A Spectral Transformer Architecture with Bayesian Learning and Edge Preservation for Photon-Counting CT Image Reconstruction
Photon-counting computed tomography (PCCT) provides energy-resolved imaging with high spectral resolution, enabling advanced material decomposition and tissue characterization. However, photon starvation and spectral distortion, especially in low-dose settings, introduce severe noise and cross-channel artifacts, significantly degrading image quality. To address these challenges, we propose a Spectral Transformer Architecture with Bayesian Learning and Edge Preservation for PCCT (STABLE-PCCT). It is a novel deep learning framework that integrates depthwise separable convolutions (DSConv), squeeze-and-excitation (SE) blocks, and a residual Transformer module as a learned prior for Bayesian reconstruction. Each spectral channel is independently processed through lightweight convolutional encoders and SE modules to extract fine spatial features and enhance channel-specific saliency. The resulting feature representations are fused and refined using a Transformer block by modeling global intra-channel dependencies and contextual relationships. A fully connected layer path generates a high-fidelity spectral output. Additionally, anisotropic diffusion filtering (ADF) is applied in the image domain to suppress noise while preserving edges and texture details. Experimental results on simulated and real extremity MARS PCCT datasets demonstrate that STABLE-PCCT outperforms the state-of-the-art baselines in preserving anatomical structures, reducing noise, and improving spectral fidelity. The proposed framework offers an efficient and scalable solution for denoising and reconstruction in low-dose PCCT and other spectral imaging applications.
- Open Access
- 1 January 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 14, 162266-162281
Tensor-Driven Spectral CT Reconstruction via Noise-Adaptive Channel Weighting and Deterministic Block Matching
- 1 January 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 14, 162266-162281
Open AccessTensor-Driven Spectral CT Reconstruction via Noise-Adaptive Channel Weighting and Deterministic Block Matching
- Open Access
- 6 February 2025
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 70 (4) , 045008
Patch-based dual-domain photon-counting CT data correction with residual-based WGAN-ViT
Objective. x-ray photon-counting detectors have recently gained popularity due to their capabilities in energy discrimination power, noise suppression, and resolution refinement. The latest extremity photon-counting computed tomography (PCCT) scanner leverages these advantages for tissue characterization, material decomposition, beam hardening correction, and metal artifact reduction. However, technical challenges such as charge splitting and pulse pileup can distort the energy spectrum and compromise image quality. Also, there is a clinical need to balance radiation dose and imaging speed for contrast-enhancement and other studies. This paper aims to address these challenges by developing a dual-domain correction approach to enhance PCCT reconstruction quality quantitatively and qualitatively. Approach. We propose a novel correction method that operates in both projection and image domains. In the projection domain, we employ a residual-based Wasserstein generative adversarial network to capture local and global features, suppressing pulse pileup, charge splitting, and data noise. This is facilitated with traditional filtering methods in the image domain to enhance signal-to-noise ratio while preserving texture across each energy channel. To address GPU memory constraints, our approach utilizes a patch-based volumetric refinement network. Main results. Our dual-domain correction approach demonstrates significant fidelity improvements across both projection and image domains. Experiments on simulated and real datasets reveal that the proposed model effectively suppresses noise and preserves intricate details, outperforming the state-of-the-art methods. Significance. This approach highlights the potential of dual-domain PCCT data correction to enhance image quality for clinical applications, showing promise for advancing PCCT image fidelity and applicability in preclinical/clinical environments.
- 6 February 2025
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 70 (4) , 045008
Open AccessPatch-based dual-domain photon-counting CT data correction with residual-based WGAN-ViT
Objective. x-ray photon-counting detectors have recently gained popularity due to their capabilities in energy discrimination power, noise suppression, and resolution refinement. The latest extremity photon-counting computed tomography (PCCT) scanner leverages these advantages for tissue characterization, material decomposition, beam hardening correction, and metal artifact reduction. However, technical challenges such as charge splitting and pulse pileup can distort the energy spectrum and compromise image quality. Also, there is a clinical need to balance radiation dose and imaging speed for contrast-enhancement and other studies. This paper aims to address these challenges by developing a dual-domain correction approach to enhance PCCT reconstruction quality quantitatively and qualitatively. Approach. We propose a novel correction method that operates in both projection and image domains. In the projection domain, we employ a residual-based Wasserstein generative adversarial network to capture local and global features, suppressing pulse pileup, charge splitting, and data noise. This is facilitated with traditional filtering methods in the image domain to enhance signal-to-noise ratio while preserving texture across each energy channel. To address GPU memory constraints, our approach utilizes a patch-based volumetric refinement network. Main results. Our dual-domain correction approach demonstrates significant fidelity improvements across both projection and image domains. Experiments on simulated and real datasets reveal that the proposed model effectively suppresses noise and preserves intricate details, outperforming the state-of-the-art methods. Significance. This approach highlights the potential of dual-domain PCCT data correction to enhance image quality for clinical applications, showing promise for advancing PCCT image fidelity and applicability in preclinical/clinical environments.
- 8 November 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Medical Imaging
- Vol. PP (02780062) , 1
Physics-informed Score-based Diffusion Model for Limited-angle Reconstruction of Cardiac Computed Tomography
Cardiac computed tomography (CT) has emerged as a major imaging modality for the diagnosis and monitoring of cardiovascular diseases. High temporal resolution is essential to ensure diagnostic accuracy. Limited-angle data acquisition can reduce scan time and improve temporal resolution, but typically leads to severe image degradation and motivates for improved reconstruction techniques. In this paper, we propose a novel physics-informed score-based diffusion model (PSDM) for limited-angle reconstruction of cardiac CT. At the sampling time, we combine a data prior from a diffusion model and a model prior obtained via an iterative algorithm and Fourier fusion to further enhance the image quality. Specifically, our approach integrates the primal-dual hybrid gradient (PDHG) algorithm with score-based diffusion models, thereby enabling us to reconstruct high-quality cardiac CT images from limited-angle data. The numerical simulations and real data experiments confirm the effectiveness of our proposed approach.
- 8 November 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Medical Imaging
- Vol. PP (02780062) , 1
Physics-informed Score-based Diffusion Model for Limited-angle Reconstruction of Cardiac Computed Tomography
Cardiac computed tomography (CT) has emerged as a major imaging modality for the diagnosis and monitoring of cardiovascular diseases. High temporal resolution is essential to ensure diagnostic accuracy. Limited-angle data acquisition can reduce scan time and improve temporal resolution, but typically leads to severe image degradation and motivates for improved reconstruction techniques. In this paper, we propose a novel physics-informed score-based diffusion model (PSDM) for limited-angle reconstruction of cardiac CT. At the sampling time, we combine a data prior from a diffusion model and a model prior obtained via an iterative algorithm and Fourier fusion to further enhance the image quality. Specifically, our approach integrates the primal-dual hybrid gradient (PDHG) algorithm with score-based diffusion models, thereby enabling us to reconstruct high-quality cardiac CT images from limited-angle data. The numerical simulations and real data experiments confirm the effectiveness of our proposed approach.