Benfang Duan
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Benfang Duan has a total of 11 co-authors. Here are the top co-authors by number of shared publications:
Biao Jia
Hanglok-Tech Co., Ltd., Hengqin, China
1 shared publication- Chen Wang
The University of Hong Kong, Hong Kong, Hong Kong
1 shared publication Cheng Wang
Hanglok-Tech Co., Ltd., Hengqin, China
1 shared publication- Gao-Jun Teng
Center of Interventional Radiology & Vascular Surgery, Department of Radiology, Zhongda Hospital, School of Medicine, Southeast University, Nanjing, China
1 shared publication - Hang Xu
School of Computing and Data Science, The University of Hong Kong, Hong Kong, SAR, China
1 shared publication - Jia Pan
The University of Hong Kong
1 shared publication
Latest Publications
- 1 July 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Robotics and Automation Letters
- Vol. 11 (7) , 8020-8027
Shared Autonomy Assisted by Impedance-Driven Anisotropic Guidance Field
- 1 July 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Robotics and Automation Letters
- Vol. 11 (7) , 8020-8027
Shared Autonomy Assisted by Impedance-Driven Anisotropic Guidance Field
- 8 November 2024
- Published by Springer Nature in International Journal of Computer Assisted Radiology and Surgery
- Vol. 20 (2) , 345-355
Optimization of percutaneous intervention robotic system for skin insertion force
Purpose Percutaneous puncture is a common interventional procedure, and its effectiveness is influenced by the insertion force of the needle. To optimize outcomes, we focus on reducing the peak force of the needle in the skin, aiming to apply this method to other tissue layers. Methods We developed a clinical puncture system, setting and measuring various variables. We analyzed their effects, introduced admittance control, set thresholds, and adjusted parameters. Finally, we validated these methods to ensure their effectiveness. Results Our system meets application requirements. We assessed the impact of various variables on peak force and validated the effectiveness of the new method. Results show a reduction of about 50% in peak force compared to the maximum force condition and about 13% compared to the minimum force condition. Finally, we summarized the factors to consider when applying this method. Conclusion To achieve peak force suppression, initial puncture variables should be set based on the trends in variable impact. Additionally, the factors of the new method should be introduced using these initial settings. When selecting these factors, the characteristics of the new method must also be considered. This process will help to better optimize peak puncture force.
- 8 November 2024
- Published by Springer Nature in International Journal of Computer Assisted Radiology and Surgery
- Vol. 20 (2) , 345-355
Optimization of percutaneous intervention robotic system for skin insertion force
Purpose Percutaneous puncture is a common interventional procedure, and its effectiveness is influenced by the insertion force of the needle. To optimize outcomes, we focus on reducing the peak force of the needle in the skin, aiming to apply this method to other tissue layers. Methods We developed a clinical puncture system, setting and measuring various variables. We analyzed their effects, introduced admittance control, set thresholds, and adjusted parameters. Finally, we validated these methods to ensure their effectiveness. Results Our system meets application requirements. We assessed the impact of various variables on peak force and validated the effectiveness of the new method. Results show a reduction of about 50% in peak force compared to the maximum force condition and about 13% compared to the minimum force condition. Finally, we summarized the factors to consider when applying this method. Conclusion To achieve peak force suppression, initial puncture variables should be set based on the trends in variable impact. Additionally, the factors of the new method should be introduced using these initial settings. When selecting these factors, the characteristics of the new method must also be considered. This process will help to better optimize peak puncture force.