Donghee Kim
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Donghee Kim has a total of 25 co-authors. Here are the top co-authors by number of shared publications:
- Kyung-Mee Park
Laboratory of Veterinary Surgery and Ophthalmology, College of Veterinary Medicine Chungbuk National University Cheongju Korea
12 shared publications - Jiyi Hwang
Laboratory of Veterinary Surgery and Ophthalmology, College of Veterinary Medicine Chungbuk National University Cheongju Korea
11 shared publications - Ji Seung Jung
Laboratory of Veterinary Surgery and Ophthalmology, College of Veterinary Medicine Chungbuk National University Cheongju Korea
10 shared publications - Haerin Yoon
Laboratory of Veterinary Surgery and Ophthalmology College of Veterinary Medicine, Chungbuk National University Cheongju Korea
5 shared publications - Myeongjee Kwon
Laboratory of Veterinary Surgery and Ophthalmology, College of Veterinary Medicine Chungbuk National University Cheongju Korea
5 shared publications - Jungyeon Yong
Laboratory of Veterinary Surgery and Ophthalmology, College of Veterinary Medicine Chungbuk National University Cheongju Korea
4 shared publications
Latest Publications
- 25 October 2026
- Published by Wiley in Veterinary Ophthalmology
- Vol. 29 (6)
Ultrasound Biomicroscopy Analysis of Ciliary Cleft, Ciliary Body, and Ciliary Muscle Changes Following Capsular Tension Ring Implantation in Dogs
Objective: To evaluate the influence of capsular tension ring (CTR) implantation during phacoemulsification on ciliary cleft, ciliary body, and ciliary muscle morphology in dogs. Methods: This prospective observational cohort study included 23 eyes from 16 dogs that underwent phacoemulsification with IOL implantation alone (11 eyes/9 dogs) or combined with CTR implantation (12 eyes/11 dogs). Four dogs contributed one eye to each group. Ultrasound biomicroscopy (UBM) was performed preoperatively and at 2–4 weeks and more than 3 months postoperatively to evaluate the iridocorneal angle, ciliary cleft, ciliary body, and ciliary muscle. Results: No preoperative differences were identified between groups. Compared with the IOL group, CTR implantation was associated with a smaller ciliary cleft, anterior displacement and compression of the ciliary body toward the corneoscleral region and thinning of the deeper ciliary muscle layers during the postoperative period. These morphological differences remained consistent at the long‐term follow‐up. Ciliary body compression by the CTR was observed in 5 of 12 eyes. Intraocular pressure (IOP) did not differ between groups. Conclusions: CTR implantation was associated with measurable morphological changes in the ciliary cleft, ciliary body, and ciliary muscle without affecting IOP. Although these changes were statistically significant, they were not associated with detectable adverse clinical effects during the follow‐up period.
- 25 October 2026
- Published by Wiley in Veterinary Ophthalmology
- Vol. 29 (6)
Ultrasound Biomicroscopy Analysis of Ciliary Cleft, Ciliary Body, and Ciliary Muscle Changes Following Capsular Tension Ring Implantation in Dogs
Objective: To evaluate the influence of capsular tension ring (CTR) implantation during phacoemulsification on ciliary cleft, ciliary body, and ciliary muscle morphology in dogs. Methods: This prospective observational cohort study included 23 eyes from 16 dogs that underwent phacoemulsification with IOL implantation alone (11 eyes/9 dogs) or combined with CTR implantation (12 eyes/11 dogs). Four dogs contributed one eye to each group. Ultrasound biomicroscopy (UBM) was performed preoperatively and at 2–4 weeks and more than 3 months postoperatively to evaluate the iridocorneal angle, ciliary cleft, ciliary body, and ciliary muscle. Results: No preoperative differences were identified between groups. Compared with the IOL group, CTR implantation was associated with a smaller ciliary cleft, anterior displacement and compression of the ciliary body toward the corneoscleral region and thinning of the deeper ciliary muscle layers during the postoperative period. These morphological differences remained consistent at the long‐term follow‐up. Ciliary body compression by the CTR was observed in 5 of 12 eyes. Intraocular pressure (IOP) did not differ between groups. Conclusions: CTR implantation was associated with measurable morphological changes in the ciliary cleft, ciliary body, and ciliary muscle without affecting IOP. Although these changes were statistically significant, they were not associated with detectable adverse clinical effects during the follow‐up period.
- 28 September 2026
- Published by Wiley in Veterinary Ophthalmology
- Vol. 29 (6) , e70276
Anterior Segment OCT Diagnosis of Descemet's Membrane Detachment in a Cat With Suspected FIP ‐Associated Uveitis
Background: Persistent corneal edema in cats with anterior uveitis is often attributed to endothelial dysfunction; however, the underlying structural cause may not be apparent without advanced imaging. Descemet's membrane detachment (DMD) is rarely reported in cats and has not been well described in suspected feline infectious peritonitis (FIP)‐associated uveitis. Animal Studied: A 4‐month‐old intact male Norwegian Forest cat presented with severe unilateral granulomatous uveitis, mutton‐fat keratic precipitates, diffuse stromal edema, and a 2+ aqueous flare. Procedures: Aqueous humor PCR detected feline coronavirus RNA, although biotype testing did not confirm a mutation consistent with that associated with feline infectious peritonitis virus. As ocular inflammation progressed despite anti‐inflammatory treatment, the nucleoside analog GS‐441524 was administered along with anti‐inflammatory and supportive ophthalmic treatment. Intraocular inflammation improved, but corneal edema persisted, prompting anterior segment optical coherence tomography (AS‐OCT), which revealed planar DMD. Serial AS‐OCT monitored posterior corneal structural changes. Results: Corneal edema gradually decreased, and Descemet's membrane reapposition was documented by AS‐OCT approximately one year after the initial presentation. Corneal clarity and stability were maintained without clinically evident recurrence for 18 months after reapposition was confirmed. Conclusions: This case describes the AS‐OCT diagnosis and serial documentation of DMD and subsequent Descemet's membrane reapposition in a cat with suspected FIP‐associated uveitis. These findings highlight the value of AS‐OCT for identifying and monitoring posterior corneal abnormalities, including DMD, in cats with severe anterior uveitis and persistent corneal edema. The relationships among suspected FIP‐associated uveitis, treatment, and DMD could not be determined from this single case.
- 28 September 2026
- Published by Wiley in Veterinary Ophthalmology
- Vol. 29 (6) , e70276
Anterior Segment OCT Diagnosis of Descemet's Membrane Detachment in a Cat With Suspected FIP ‐Associated Uveitis
Background: Persistent corneal edema in cats with anterior uveitis is often attributed to endothelial dysfunction; however, the underlying structural cause may not be apparent without advanced imaging. Descemet's membrane detachment (DMD) is rarely reported in cats and has not been well described in suspected feline infectious peritonitis (FIP)‐associated uveitis. Animal Studied: A 4‐month‐old intact male Norwegian Forest cat presented with severe unilateral granulomatous uveitis, mutton‐fat keratic precipitates, diffuse stromal edema, and a 2+ aqueous flare. Procedures: Aqueous humor PCR detected feline coronavirus RNA, although biotype testing did not confirm a mutation consistent with that associated with feline infectious peritonitis virus. As ocular inflammation progressed despite anti‐inflammatory treatment, the nucleoside analog GS‐441524 was administered along with anti‐inflammatory and supportive ophthalmic treatment. Intraocular inflammation improved, but corneal edema persisted, prompting anterior segment optical coherence tomography (AS‐OCT), which revealed planar DMD. Serial AS‐OCT monitored posterior corneal structural changes. Results: Corneal edema gradually decreased, and Descemet's membrane reapposition was documented by AS‐OCT approximately one year after the initial presentation. Corneal clarity and stability were maintained without clinically evident recurrence for 18 months after reapposition was confirmed. Conclusions: This case describes the AS‐OCT diagnosis and serial documentation of DMD and subsequent Descemet's membrane reapposition in a cat with suspected FIP‐associated uveitis. These findings highlight the value of AS‐OCT for identifying and monitoring posterior corneal abnormalities, including DMD, in cats with severe anterior uveitis and persistent corneal edema. The relationships among suspected FIP‐associated uveitis, treatment, and DMD could not be determined from this single case.
- Open Access
- 12 July 2026
- Published by Wiley in Veterinary Ophthalmology
- Vol. 29 (5) , e70231
Ultrasound Biomicroscopic Evaluation of Postoperative Anterior Segment Changes in Canine Intumescent Cataracts
Objective: This study aimed to evaluate pre‐ and postoperative changes in the iridocorneal angle, ciliary cleft (CC), and ciliary muscle (CM) in canine eyes with intumescent cataracts using ultrasound biomicroscopy (UBM), with comparative reference to normal and non‐intumescent cataractous eyes. Methods: UBM was performed preoperatively on 61 eyes from 40 dogs, classified into 3 groups: (a) normal ( n = 18), (b) cataract ( n = 23), and (c) intumescent ( n = 20) groups. Following surgery, UBM measurements were conducted on 51 eyes from 37 dogs: (d) postoperative (PO)‐cataract ( n = 21) and (e) PO‐intumescent ( n = 29) groups. Pre‐ and postoperative measurements were obtained from independent groups of dogs. Parameters analyzed included angle opening distance (AOD), iridocorneal angle (ICA), ciliary cleft width (CCW), ciliary cleft length (CCL), ciliary cleft area (CCA), ciliary body axial length (CBAXL), ciliary process‐sclera angle (CPSA), and ciliary body muscle thickness (CBMT). Results: The intumescent cataract group showed significant narrowing of CC collapse. Postoperatively, ICA and CC were significantly wider in the intumescent group, while no significant postoperative difference was observed in CM thickness. Conclusion: Intumescent cataracts were characterized by narrowing of the anterior chamber angle and collapse of CC, whereas phacoemulsification was associated with partial widening of CC parameters. These findings suggest that anterior segment structural changes are associated with postoperative prognosis in dogs with intumescent cataracts.
- 12 July 2026
- Published by Wiley in Veterinary Ophthalmology
- Vol. 29 (5) , e70231
Open AccessUltrasound Biomicroscopic Evaluation of Postoperative Anterior Segment Changes in Canine Intumescent Cataracts
Objective: This study aimed to evaluate pre‐ and postoperative changes in the iridocorneal angle, ciliary cleft (CC), and ciliary muscle (CM) in canine eyes with intumescent cataracts using ultrasound biomicroscopy (UBM), with comparative reference to normal and non‐intumescent cataractous eyes. Methods: UBM was performed preoperatively on 61 eyes from 40 dogs, classified into 3 groups: (a) normal ( n = 18), (b) cataract ( n = 23), and (c) intumescent ( n = 20) groups. Following surgery, UBM measurements were conducted on 51 eyes from 37 dogs: (d) postoperative (PO)‐cataract ( n = 21) and (e) PO‐intumescent ( n = 29) groups. Pre‐ and postoperative measurements were obtained from independent groups of dogs. Parameters analyzed included angle opening distance (AOD), iridocorneal angle (ICA), ciliary cleft width (CCW), ciliary cleft length (CCL), ciliary cleft area (CCA), ciliary body axial length (CBAXL), ciliary process‐sclera angle (CPSA), and ciliary body muscle thickness (CBMT). Results: The intumescent cataract group showed significant narrowing of CC collapse. Postoperatively, ICA and CC were significantly wider in the intumescent group, while no significant postoperative difference was observed in CM thickness. Conclusion: Intumescent cataracts were characterized by narrowing of the anterior chamber angle and collapse of CC, whereas phacoemulsification was associated with partial widening of CC parameters. These findings suggest that anterior segment structural changes are associated with postoperative prognosis in dogs with intumescent cataracts.
- 29 June 2026
- Published by Wiley in Veterinary Ophthalmology
- Vol. 29 (4) , e70221
Stent‐Assisted Surgical Creation of a Ductal Drainage Tract in the Third Eyelid Gland for Treatment of Postoperative Lacrimal Cyst of the Nictitating Membrane in a Dog
Objective: To describe a surgical technique of stent‐assisted creation of a ductal drainage tract in the third eyelid gland, combined with mitomycin‐C application, for the treatment of recurrent lacrimal cyst of the nictitating membrane (LCNM) in a referred dog. Animal Studied: A client‐owned 8‐month‐old castrated male Maltese dog (3.6 kg) with recurrent LCNM following conjunctival pocket technique for PNMG repair. Procedures: Following two recurrences after surgical cyst drainage via intentional incision, stent‐assisted ductal tract creation was performed, incorporating mitomycin‐C (0.4 mg/mL) application and temporary placement of a 3‐French cat catheter as a ductal stent. The stent was removed at the one‐week recheck due to a stent‐related corneal ulcer, 1 week earlier than planned. Results: A focal central superficial corneal ulcer attributed to mechanical contact with the catheter stent was identified at the one‐week recheck and necessitated early stent removal; the ulcer resolved with topical antibiotic therapy. At the three‐week recheck, mild nictitating membrane (NM) elevation and incomplete ductal patency were noted. By the six‐week recheck, NM protrusion and conjunctival hyperemia had resolved and corticosteroid therapy was discontinued. No cyst recurrence was observed over 4 months, and the created ductal tract remained patent. Conclusion: This technique achieved resolution of recurrent LCNM and maintained ductal patency over 4 months. Stent‐related corneal contact necessitated early stent removal. The suture‐free nature suggests this technique may be performed without dedicated surgical microscopy, potentially broadening its applicability in general practice.
- 29 June 2026
- Published by Wiley in Veterinary Ophthalmology
- Vol. 29 (4) , e70221
Stent‐Assisted Surgical Creation of a Ductal Drainage Tract in the Third Eyelid Gland for Treatment of Postoperative Lacrimal Cyst of the Nictitating Membrane in a Dog
Objective: To describe a surgical technique of stent‐assisted creation of a ductal drainage tract in the third eyelid gland, combined with mitomycin‐C application, for the treatment of recurrent lacrimal cyst of the nictitating membrane (LCNM) in a referred dog. Animal Studied: A client‐owned 8‐month‐old castrated male Maltese dog (3.6 kg) with recurrent LCNM following conjunctival pocket technique for PNMG repair. Procedures: Following two recurrences after surgical cyst drainage via intentional incision, stent‐assisted ductal tract creation was performed, incorporating mitomycin‐C (0.4 mg/mL) application and temporary placement of a 3‐French cat catheter as a ductal stent. The stent was removed at the one‐week recheck due to a stent‐related corneal ulcer, 1 week earlier than planned. Results: A focal central superficial corneal ulcer attributed to mechanical contact with the catheter stent was identified at the one‐week recheck and necessitated early stent removal; the ulcer resolved with topical antibiotic therapy. At the three‐week recheck, mild nictitating membrane (NM) elevation and incomplete ductal patency were noted. By the six‐week recheck, NM protrusion and conjunctival hyperemia had resolved and corticosteroid therapy was discontinued. No cyst recurrence was observed over 4 months, and the created ductal tract remained patent. Conclusion: This technique achieved resolution of recurrent LCNM and maintained ductal patency over 4 months. Stent‐related corneal contact necessitated early stent removal. The suture‐free nature suggests this technique may be performed without dedicated surgical microscopy, potentially broadening its applicability in general practice.
- Open Access
- 23 June 2026
- Published by Wiley in Veterinary Medicine and Science
- Vol. 12 (4) , e71046
Hyaluronic Acid‐Based Photocurable Glue Application as an Alternative Surgical Approach for Corneal Injuries in Canine Patients: A Case Series
Effective non‐surgical alternatives are required for managing severe corneal injuries in dogs when surgical intervention is not feasible. This case series evaluated the therapeutic potential of hyaluronic acid (HA)‐based photocurable glue (HA photoglue, Teratouch‐ETM, SNVIA) in three dogs with deep corneal injuries. Case 1 was a 16‐year‐old Pekingese with systemic disease presenting with a descemetocele. Case 2 was a 14‐year‐old Maltese with diabetes mellitus and a corneal perforation. Case 3 was a 10‐year‐old mixed‐breed dog with a corneal laceration involving 50 % stromal depth. All cases underwent topical anaesthesia and light sedation. A 20 µL drop of HA photoglue was applied to the lesion and photocrosslinked with short visible light (405 nm, 4.3 s). Applications were repeated during follow‐up depending on lesion size and adhesive stability. In Case 1, 16 applications over 9 months maintained corneal integrity and transparency without perforation or inflammation. In Case 2, five sequential applications over 3 months achieved complete re‐epithelialisation and stromal remodelling. In Case 3, a single treatment resulted in full epithelial closure by two weeks, and corneal clarity and visual function were fully restored by eight weeks. This case series suggests that HA photoglue may serve as a safe and minimally invasive therapeutic approach for canine corneal injuries, providing mechanical stabilisation and demonstrating clinical potential when conventional surgery is not feasible.
- 23 June 2026
- Published by Wiley in Veterinary Medicine and Science
- Vol. 12 (4) , e71046
Open AccessHyaluronic Acid‐Based Photocurable Glue Application as an Alternative Surgical Approach for Corneal Injuries in Canine Patients: A Case Series
Effective non‐surgical alternatives are required for managing severe corneal injuries in dogs when surgical intervention is not feasible. This case series evaluated the therapeutic potential of hyaluronic acid (HA)‐based photocurable glue (HA photoglue, Teratouch‐ETM, SNVIA) in three dogs with deep corneal injuries. Case 1 was a 16‐year‐old Pekingese with systemic disease presenting with a descemetocele. Case 2 was a 14‐year‐old Maltese with diabetes mellitus and a corneal perforation. Case 3 was a 10‐year‐old mixed‐breed dog with a corneal laceration involving 50 % stromal depth. All cases underwent topical anaesthesia and light sedation. A 20 µL drop of HA photoglue was applied to the lesion and photocrosslinked with short visible light (405 nm, 4.3 s). Applications were repeated during follow‐up depending on lesion size and adhesive stability. In Case 1, 16 applications over 9 months maintained corneal integrity and transparency without perforation or inflammation. In Case 2, five sequential applications over 3 months achieved complete re‐epithelialisation and stromal remodelling. In Case 3, a single treatment resulted in full epithelial closure by two weeks, and corneal clarity and visual function were fully restored by eight weeks. This case series suggests that HA photoglue may serve as a safe and minimally invasive therapeutic approach for canine corneal injuries, providing mechanical stabilisation and demonstrating clinical potential when conventional surgery is not feasible.
- Open Access
- 6 January 2026
- Published by MDPI AG in Veterinary Sciences
- Vol. 13 (1) , 50
Anterior Segment Measurements in Normal Cats Using Ultrasound Biomicroscopy
Establishing baseline ultrasound biomicroscopy (UBM) measurements of the feline anterior segment is essential for accurate evaluation of ocular diseases. This study aimed to establish normative UBM parameters in clinically normal cats and to assess the influence of sex, body weight, and age on these measurements. Twenty eyes from twenty healthy adult cats were examined using a standardized UBM protocol under general anesthesia to ensure consistent positioning and optimal visualization. Quantitative measurements were obtained for corneal, anterior chamber, iris, ciliary cleft, and ciliary body parameters. The mean perilimbal corneal thickness was 0.59 mm, anterior chamber depth was 4.11 mm, and peripheral anterior chamber depth was 3.11 mm. The angle-opening distance and iridocorneal angle measured 1.73 mm and 28.89°, respectively. Ciliary cleft parameters included a width of 1.22 mm, length of 2.07 mm, and area of 1.10 mm2. Longitudinal and combined longitudinal–radial ciliary body thicknesses were 0.52 mm and 0.78 mm, respectively, while ciliary body axial length and ciliary process scleral angle averaged 2.01 mm and 58.98°. Iris base width and iris middle width measured 0.35 mm and 0.54 mm, respectively. Sex-based analysis revealed significant differences in peripheral anterior chamber depth and ciliary cleft width, whereas body weight showed positive correlations with iris thickness parameters. No significant associations were identified between age and any anterior segment measurements. These findings establish comprehensive normative UBM reference values for the feline anterior segment and provide a quantitative anatomical framework for future clinical and disease-oriented studies in feline ophthalmology.
- 6 January 2026
- Published by MDPI AG in Veterinary Sciences
- Vol. 13 (1) , 50
Open AccessAnterior Segment Measurements in Normal Cats Using Ultrasound Biomicroscopy
Establishing baseline ultrasound biomicroscopy (UBM) measurements of the feline anterior segment is essential for accurate evaluation of ocular diseases. This study aimed to establish normative UBM parameters in clinically normal cats and to assess the influence of sex, body weight, and age on these measurements. Twenty eyes from twenty healthy adult cats were examined using a standardized UBM protocol under general anesthesia to ensure consistent positioning and optimal visualization. Quantitative measurements were obtained for corneal, anterior chamber, iris, ciliary cleft, and ciliary body parameters. The mean perilimbal corneal thickness was 0.59 mm, anterior chamber depth was 4.11 mm, and peripheral anterior chamber depth was 3.11 mm. The angle-opening distance and iridocorneal angle measured 1.73 mm and 28.89°, respectively. Ciliary cleft parameters included a width of 1.22 mm, length of 2.07 mm, and area of 1.10 mm2. Longitudinal and combined longitudinal–radial ciliary body thicknesses were 0.52 mm and 0.78 mm, respectively, while ciliary body axial length and ciliary process scleral angle averaged 2.01 mm and 58.98°. Iris base width and iris middle width measured 0.35 mm and 0.54 mm, respectively. Sex-based analysis revealed significant differences in peripheral anterior chamber depth and ciliary cleft width, whereas body weight showed positive correlations with iris thickness parameters. No significant associations were identified between age and any anterior segment measurements. These findings establish comprehensive normative UBM reference values for the feline anterior segment and provide a quantitative anatomical framework for future clinical and disease-oriented studies in feline ophthalmology.
- 6 October 2025
- Published by Wiley in Veterinary Ophthalmology
- Vol. 29 (2)
Ultrasound Biomicroscopic Study of the Effects of 1% Tropicamide on the Anterior Segment and Ciliary Body in Cats
Objective: To investigate the effects of 1% tropicamide on intraocular pressure (IOP), anterior chamber morphology, and ciliary body dynamics in cats using ultrasound biomicroscopy (UBM). Methods: A total of 28 eyes from 14 clinically healthy cats were evaluated before and 30 min after unilateral instillation of 1% tropicamide in the right eye (OD), with the left eye (OS) serving as a control. Parameters assessed included pupil size, IOP, and UBM‐derived measurements of the iridocorneal angle (ICA), angle opening distance (AOD), ciliary cleft width (CCW), length (CCL), area (CCA), ciliary body axial length (CBAXL), and ciliary process–scleral angle (CPSA). Results: Tropicamide significantly increased IOP in the treated eye (OD) but not in the control eye (OS). UBM analysis revealed significant reductions in ICA and CCW in OD, while other anterior chamber and ciliary body parameters showed no meaningful changes. In contrast, no significant alterations were observed in any anterior chamber or ciliary body parameters in OS. Conclusion: These findings suggest that tropicamide‐induced IOP elevation in cats results from anterior chamber angle narrowing, emphasizing the need for caution when using mydriatics in patients at risk for ocular hypertension.
- 6 October 2025
- Published by Wiley in Veterinary Ophthalmology
- Vol. 29 (2)
Ultrasound Biomicroscopic Study of the Effects of 1% Tropicamide on the Anterior Segment and Ciliary Body in Cats
Objective: To investigate the effects of 1% tropicamide on intraocular pressure (IOP), anterior chamber morphology, and ciliary body dynamics in cats using ultrasound biomicroscopy (UBM). Methods: A total of 28 eyes from 14 clinically healthy cats were evaluated before and 30 min after unilateral instillation of 1% tropicamide in the right eye (OD), with the left eye (OS) serving as a control. Parameters assessed included pupil size, IOP, and UBM‐derived measurements of the iridocorneal angle (ICA), angle opening distance (AOD), ciliary cleft width (CCW), length (CCL), area (CCA), ciliary body axial length (CBAXL), and ciliary process–scleral angle (CPSA). Results: Tropicamide significantly increased IOP in the treated eye (OD) but not in the control eye (OS). UBM analysis revealed significant reductions in ICA and CCW in OD, while other anterior chamber and ciliary body parameters showed no meaningful changes. In contrast, no significant alterations were observed in any anterior chamber or ciliary body parameters in OS. Conclusion: These findings suggest that tropicamide‐induced IOP elevation in cats results from anterior chamber angle narrowing, emphasizing the need for caution when using mydriatics in patients at risk for ocular hypertension.
- Open Access
- 19 March 2025
- Published by Springer Nature in BMC Veterinary Research
- Vol. 21 (1) , 1-9
Comparative analysis of iridocorneal angle in cats and dogs using ultrasound biomicroscopy: implications for glaucoma prevalence
This study aims to investigate the anatomical differences in the anterior segment of the eyes between dogs and cats using ultrasound biomicroscopy (UBM) to understand the higher prevalence of primary angle-closure glaucoma (PACG) in dogs compared to cats. Retrospective analysis was performed on clinical data from 16 eyes of 16 dogs and 14 eyes of 14 cats with normal eye conditions. UBM was utilized to measure nine specific parameters, including Schwalbe’s Line Distance (SLD), Iridocorneal Angle (ICA), Angle-Opening Distance (AOD), and three ciliary cleft parameters: width (CCW), length (CCL), and area (CCA). To account for differences in body size, ciliary cleft parameters were adjusted accordingly. Significant anatomical differences in the anterior segment were found between the two species. Dogs had smaller values for SLD, ICA, AOD, and ciliary cleft parameters (CCW, CCL, CCA) compared to cats. Even after body-size adjustment, the rectified ciliary cleft parameters remained smaller in dogs. The anatomical differences, particularly the smaller ciliary cleft and narrower drainage angles in dogs, may contribute to the higher prevalence of PACG in this species. Conversely, the larger ciliary cleft in cats may explain the lower occurrence of primary glaucoma in cats.
- 19 March 2025
- Published by Springer Nature in BMC Veterinary Research
- Vol. 21 (1) , 1-9
Open AccessComparative analysis of iridocorneal angle in cats and dogs using ultrasound biomicroscopy: implications for glaucoma prevalence
This study aims to investigate the anatomical differences in the anterior segment of the eyes between dogs and cats using ultrasound biomicroscopy (UBM) to understand the higher prevalence of primary angle-closure glaucoma (PACG) in dogs compared to cats. Retrospective analysis was performed on clinical data from 16 eyes of 16 dogs and 14 eyes of 14 cats with normal eye conditions. UBM was utilized to measure nine specific parameters, including Schwalbe’s Line Distance (SLD), Iridocorneal Angle (ICA), Angle-Opening Distance (AOD), and three ciliary cleft parameters: width (CCW), length (CCL), and area (CCA). To account for differences in body size, ciliary cleft parameters were adjusted accordingly. Significant anatomical differences in the anterior segment were found between the two species. Dogs had smaller values for SLD, ICA, AOD, and ciliary cleft parameters (CCW, CCL, CCA) compared to cats. Even after body-size adjustment, the rectified ciliary cleft parameters remained smaller in dogs. The anatomical differences, particularly the smaller ciliary cleft and narrower drainage angles in dogs, may contribute to the higher prevalence of PACG in this species. Conversely, the larger ciliary cleft in cats may explain the lower occurrence of primary glaucoma in cats.
- Open Access
- 16 March 2025
- Published by Wiley in Veterinary Ophthalmology
- Vol. 29 (1)
Intraocular Pressure Increase Induced by 0.5% Tropicamide‐0.5% Phenylephrine in Dogs: An Analysis of Causes Using Ultrasound Biomicroscopy
Purpose: To determine whether the differences in intraocular pressure (IOP) change after the topical application of 0.5% tropicamide and 0.5% phenylephrine (TP) are due to anatomical variations in the anterior chamber using ultrasound biomicroscopy (UBM). Methods: Prospective clinical data from 27 eyes of 14 dogs with normal eye conditions were analyzed. IOP and UBM measurements were taken before and 30 min after administering a topical TP. Dogs were categorized into two groups based on an IOP increase criterion of 4 mmHg: the high group and the stable group. Parameters measured included the iridocorneal angle (ICA), angle‐opening distance (AOD), ciliary cleft width (CCW), length (CCL), area (CCA), ciliary body axial length (CBAXL), and ciliary process‐sclera angle (CPSA). Results: Both groups showed a statistically significant decrease in ICA and an increase in AOD. However, in the stable group, CPSA increased, CBAXL decreased, and CCA increased, whereas in the high group, CPSA and CBAXL did not change significantly, and CCA decreased. Conclusion: In the stable group, although the pupil dilated, the ciliary body relaxed, leading to an increase in the CCA. Conversely, in the high group, the pupil dilated, and the ciliary body remained unrelaxed, resulting in a reduction in the CCA. These iridociliary changes with pupil dilation increase the risk of elevated IOP. Therefore, an increase in IOP following TP administration may serve as a prognostic indicator for possible glaucoma risk.
- 16 March 2025
- Published by Wiley in Veterinary Ophthalmology
- Vol. 29 (1)
Open AccessIntraocular Pressure Increase Induced by 0.5% Tropicamide‐0.5% Phenylephrine in Dogs: An Analysis of Causes Using Ultrasound Biomicroscopy
Purpose: To determine whether the differences in intraocular pressure (IOP) change after the topical application of 0.5% tropicamide and 0.5% phenylephrine (TP) are due to anatomical variations in the anterior chamber using ultrasound biomicroscopy (UBM). Methods: Prospective clinical data from 27 eyes of 14 dogs with normal eye conditions were analyzed. IOP and UBM measurements were taken before and 30 min after administering a topical TP. Dogs were categorized into two groups based on an IOP increase criterion of 4 mmHg: the high group and the stable group. Parameters measured included the iridocorneal angle (ICA), angle‐opening distance (AOD), ciliary cleft width (CCW), length (CCL), area (CCA), ciliary body axial length (CBAXL), and ciliary process‐sclera angle (CPSA). Results: Both groups showed a statistically significant decrease in ICA and an increase in AOD. However, in the stable group, CPSA increased, CBAXL decreased, and CCA increased, whereas in the high group, CPSA and CBAXL did not change significantly, and CCA decreased. Conclusion: In the stable group, although the pupil dilated, the ciliary body relaxed, leading to an increase in the CCA. Conversely, in the high group, the pupil dilated, and the ciliary body remained unrelaxed, resulting in a reduction in the CCA. These iridociliary changes with pupil dilation increase the risk of elevated IOP. Therefore, an increase in IOP following TP administration may serve as a prognostic indicator for possible glaucoma risk.
- 14 January 2025
- Published by Wiley in Veterinary Ophthalmology
- Vol. 29 (1)
Dexamethasone–Antibiotic Interactions in Canine Ocular Bacteria: In Vitro Susceptibility Changes in Common Corneal Infection Pathogens
Objective: To investigate the impact of dexamethasone on the antibiotic susceptibility of common ocular pathogens in dogs and identify safe antibiotic‐steroid combinations for veterinary ophthalmology. Methods: This study utilized 30 bacterial isolates of Staphylococcus pseudintermedius , Streptococcus canis , and Pseudomonas aeruginosa , collected from canine patients with suspected bacterial keratitis. The isolates were tested against 17 antibiotics in the presence of dexamethasone concentrations ranging from 0 to 2 mg/mL. Minimum inhibitory concentrations (MICs) were determined using standardized broth microdilution techniques, and changes in susceptibility were analyzed statistically. Results: Dexamethasone administration resulted in a significant increase in resistance for ciprofloxacin, ticarcillin, tobramycin, and ceftiofur in S. pseudintermedius ; ticarcillin in S. canis ; and ciprofloxacin and moxifloxacin in P. aeruginosa . Despite these increases, amikacin and cefazolin showed minimal impact on resistance when combined with dexamethasone, indicating their potential for safe use in combination therapies. Conclusion: The findings highlight the potential for dexamethasone to alter antibiotic susceptibility in canine ocular pathogens. While dexamethasone can increase resistance in certain antibiotics, amikacin and cefazolin appear to be safer options for combination therapy.
- 14 January 2025
- Published by Wiley in Veterinary Ophthalmology
- Vol. 29 (1)
Dexamethasone–Antibiotic Interactions in Canine Ocular Bacteria: In Vitro Susceptibility Changes in Common Corneal Infection Pathogens
Objective: To investigate the impact of dexamethasone on the antibiotic susceptibility of common ocular pathogens in dogs and identify safe antibiotic‐steroid combinations for veterinary ophthalmology. Methods: This study utilized 30 bacterial isolates of Staphylococcus pseudintermedius , Streptococcus canis , and Pseudomonas aeruginosa , collected from canine patients with suspected bacterial keratitis. The isolates were tested against 17 antibiotics in the presence of dexamethasone concentrations ranging from 0 to 2 mg/mL. Minimum inhibitory concentrations (MICs) were determined using standardized broth microdilution techniques, and changes in susceptibility were analyzed statistically. Results: Dexamethasone administration resulted in a significant increase in resistance for ciprofloxacin, ticarcillin, tobramycin, and ceftiofur in S. pseudintermedius ; ticarcillin in S. canis ; and ciprofloxacin and moxifloxacin in P. aeruginosa . Despite these increases, amikacin and cefazolin showed minimal impact on resistance when combined with dexamethasone, indicating their potential for safe use in combination therapies. Conclusion: The findings highlight the potential for dexamethasone to alter antibiotic susceptibility in canine ocular pathogens. While dexamethasone can increase resistance in certain antibiotics, amikacin and cefazolin appear to be safer options for combination therapy.