Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Kaizhe Jin has a total of 24 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    ECG-Only Cognitive Workload State Classification in Laparoscopic Training Using Raw and Recurrence-Plot Representations

    by Kaizhe Jin, Adrian Rubio-Solis, Ravi Naik, George Mylonas

    Electrocardiography (ECG)-only workload-state classification offers a lower-burden physiological sensing route than denser multimodal, multi-sensor physiological, or neuroimaging setups for controlled laparoscopic training research. This study evaluated whether ECG-only representations can classify condition-derived cognitive workload states during a controlled laparoscopic peg transfer task performed under Control and auditory N-back conditions (N0, N1, and N2). Twenty surgical trainees from an advanced surgical-skills course completed the task protocol, and 17 participants entered ECG modelling after ECG quality-control exclusions. The retained ECG modelling dataset comprised 268 task blocks (Control/N0/N1/N2: 68/68/68/64), evaluated as held-out task-block predictions in a known-participant four-fold leave-one-round-out (LOTO) evaluation. Branch-specific raw ECG windows, recurrence-plot sequences, and heart-rate/time-domain heart-rate-variability inputs are detailed in the Methods, and model metrics were computed after reduction to task-block predictions. The primary endpoint was Surgery Task Load Index (SURG-TLX)-aligned low/high workload, defined as Control plus N0 versus N1 plus N2. Four-class and three-level endpoints were retained as secondary views. Raw ECG, recurrence-plot (RP)-derived, hybrid score-level fusion, and conventional heart-rate/time-domain heart-rate-variability Random Forest (HRV-RF) models were compared using a locked evaluation protocol, leakage-aware train-fold-only preprocessing, participant-clustered confidence intervals, and planned paired tests for the primary endpoint. On the primary low/high endpoint, raw ECG achieved the highest macro-F1/balanced accuracy (0.865/0.865), followed by the hybrid branch (0.847/0.847) and HRV-RF (0.648/0.649). Raw ECG and hybrid were supported over RP-derived and HRV-RF under the planned paired tests. On selected secondary endpoints, hybrid achieved higher macro-F1 values than raw ECG, consistent with possible endpoint-dependent RP-derived complementarity rather than a general hybrid advantage. These findings support ECG-only block-level workload-state classification in this controlled training setting. The evidence is retrospective and based on held-out rounds from known participants rather than subject-independent or deployment validation.

  • Open Access

    Human-Centric Cognitive State Recognition Using Physiological Signals: A Systematic Review of Machine Learning Strategies Across Application Domains

    by Kaizhe Jin, Adrian Rubio-Solis, Ravi Naik, Daniel Leff, James Kinross, George Mylonas

    This systematic review analyses advancements in cognitive state recognition from 2010 to early 2024, evaluating 405 relevant articles from an initial pool of 2398 records identified through five databases: Scopus, Engineering Village, Web of Science, IEEE Xplore, and PubMed. Studies were included if they assessed cognitive states using physiological signals and applied machine learning (ML) or deep learning (DL) techniques in practical task settings. The review highlights a pivotal shift from shallow ML to DL approaches for analysing physiological signals, driven by DL’s ability to autonomously learn complex patterns in large datasets. By 2023, DL has become the dominant methodology, though traditional ML techniques remain relevant. Additionally, there has been a move from neuroimaging to multimodal physiological modalities, with the decrease in neuroimaging use reflecting a trend towards integrating various physiological signals for more comprehensive insights. Cognitive state recognition is applied across diverse domains such as the automotive, aviation, maritime, and healthcare industries, enhancing performance and safety in high-stakes environments. Electrocardiogram (ECG) is the most utilised modality, with convolutional neural networks (CNNs) being the primary DL approach. The trend in cognitive state recognition research is moving towards integrating ECG signals with CNNs and adopting privacy-preserving methodologies like differential privacy and federated learning, highlighting the potential of cognitive state recognition to enhance performance, safety, and innovation across various real-world applications.


  • Open Access

    378 Workload Assessment of Suturing Tasks and AI-Task Classification Using Electromyography

    by H Karaiossifides, R Naik, A Rubio-Solis, K Jin, G Mylonas

    Aim: It is well established that excess surgeon workload results in poorer performance. Workload can be divided into physical workload (PWL) and cognitive workload (CWL). The study aims are twofold: 1. Assess how the subjective PWL of suturing is affected by varying PWL and CWL 2. Develop an AI-classification algorithm for task detection using electromyography (EMG). Method: Novices were trained in interrupted suturing and asked to suture under four conditions of varied workload. Tasks included were: 1. Control, 2. Different suture material (Silk), 3. Simultaneously undertaking a neurocognitive task and 4. Suturing at depth. Subjective workload was recorded using a validated workload questionnaire (SURG-TLX). EMG sensors recorded physiological data from the biceps brachii and extensor ulnar carpi. A convolutional neural network (CNN) was created for AI-task classification using EMG data. Results: The depth task had the highest subjective workload. Subjective depth raw workload was significantly higher than Control (p=<0.01) and Silk (p=<0.001) but comparable to the neurocognitive task. Subjective depth weighted workload was significantly higher than the neurocognitive task (p=<0.05). Subjective depth adjusted workload was significantly higher than the neurocognitive and silk tasks (both p=<0.05). The CNN training accuracy was 76.4% (95%CI 75.5-77.4) and had a classification accuracy of 76.5% (95%CI 75.7-77.2). Conclusions: The relationship between PWL and CWL on subjective PWL is complex. Despite this, the CNN was able to differentiate between tasks using objective EMG data with good accuracy. This CNN has potential to characterise CWL which can be further developed to detect excess workload to improve surgical training through objective benchmarks.

  • Open Access

    Identification of Cognitive Workload during Surgical Tasks with Multimodal Deep Learning

    by Kaizhe Jin, Adrian Rubio-Solis, Ravi Naik, Tochukwu Onyeogulu, Amirul Islam, Salman Khan, Izzeddin Teeti, James Kinross, Daniel R Leff, Fabio Cuzzolin, et al.

    The operating room (OR) is a dynamic and complex environment consisting of a multidisciplinary team working together in a high take environment to provide safe and efficient patient care. Additionally, surgeons are frequently exposed to multiple psycho-organisational stressors that may cause negative repercussions on their immediate technical performance and long-term health. Many factors can therefore contribute to increasing the Cognitive Workload (CWL) such as temporal pressures, unfamiliar anatomy or distractions in the OR. In this paper, a cascade of two machine learning approaches is suggested for the multimodal recognition of CWL in four different surgical task conditions. Firstly, a model based on the concept of transfer learning is used to identify if a surgeon is experiencing any CWL. Secondly, a Convolutional Neural Network (CNN) uses this information to identify different degrees of CWL associated to each surgical task. The suggested multimodal approach considers adjacent signals from electroencephalogram (EEG), functional near-infrared spectroscopy (fNIRS) and eye pupil diameter. The concatenation of signals allows complex correlations in terms of time (temporal) and channel location (spatial). Data collection was performed by a Multi-sensing AI Environment for Surgical Task & Role Optimisation platform (MAESTRO) developed at the Hamlyn Centre, Imperial College London. To compare the performance of the proposed methodology, a number of state-of-art machine learning techniques have been implemented. The tests show that the proposed model has a precision of 93%.


  • Open Access

    Situation Awareness for Automated Surgical Check-listing in AI-Assisted Operating Room

    by Tochukwu Onyeogulu, Salman Khan, Izzeddin Teeti, Amirul Islam, Kaizhe Jin, Adrian Rubio-Solis, Ravi Naik, George Mylonas, Fabio Cuzzolin

    Nowadays, there are more surgical procedures that are being performed using minimally invasive surgery (MIS). This is due to its many benefits, such as minimal post-operative problems, less bleeding, minor scarring, and a speedy recovery. However, the MIS's constrained field of view, small operating room, and indirect viewing of the operating scene could lead to surgical tools colliding and potentially harming human organs or tissues. Therefore, MIS problems can be considerably reduced, and surgical procedure accuracy and success rates can be increased by using an endoscopic video feed to detect and monitor surgical instruments in real-time. In this paper, a set of improvements made to the YOLOV5 object detector to enhance the detection of surgical instruments was investigated, analyzed, and evaluated. In doing this, we performed performance-based ablation studies, explored the impact of altering the YOLOv5 model's backbone, neck, and anchor structural elements, and annotated a unique endoscope dataset. Additionally, we compared the effectiveness of our ablation investigations with that of four additional SOTA object detectors (YOLOv7, YOLOR, Scaled-YOLOv4 and YOLOv3-SPP). Except for YOLOv3-SPP, which had the same model performance of 98.3% in mAP and a similar inference speed, all of our benchmark models, including the original YOLOv5, were surpassed by our top refined model in experiments using our fresh endoscope dataset.


  • Preliminary findings of a multimodal sensor system for measuring surgeon cognitive workload

    by Ravi Naik, Kaizhe Jin, Alexandros Kogkas, Hutan Ashrafian, Ara Darzi, George Mylonas

    The operating room represents a high-risk environment centred around the safe and efficient delivery of patient care. It is a complex ecosystem that encompasses many factors including communication within the multidisciplinary surgical team often led by the operating surgeon as well as execution of precise technical surgical skill. These factors are associated with the mental or cognitive workload (CWL) of the surgeon. CWL, also described as the mental effort exerted while undertaking a task, is a construct derived from the cognitive load theory first described in the eighties during problem solving exercises [1]. There has been a growing emphasis on the measurement of CWL since then on individuals working in high-stake environments such as aviation [2]. Measurement of CWL in surgery is moving from solitary traditional subjective measures such as the Surgical Task Load Index (SURG-TLX) to objective measurement of physiological parameters secondary to changes in the CWL of the surgeon which are less exposed to subjective bias [3]. These have included heart rate variability (HRV), pupil metrics, electromyography (EMG), electroencephalography (EEG), skin conductance and functional near-infrared spectroscopy (fNIRS). More recently, there is increasing evidence to demonstrate the use of multiple sensors, or a multimodal sensor system designed to measure CWL with greater accuracy [4]. The aim of this paper is to demonstrate the use of a pilot synchronised system of multiple sensors to measure the real-time cognitive workload of surgeons in a simulated setting to demonstrate a proof of concept and to discuss the early findings.