Huiqiang Ye
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Huiqiang Ye has a total of 11 co-authors. Here are the top co-authors by number of shared publications:
- David Raisz
Department of Electric Power Engineering, Budapest University of Technology and Economics, 1111 Budapest, Hungary
1 shared publication - Fangzhou Liu
State Grid Zhejiang Electric Power Co., Ltd., Hangzhou 310012, China
1 shared publication - Lifeng Zhu
State Grid Zhejiang Electric Power Co., Ltd., Hangzhou 310012, China
1 shared publication - Luona Xu
State Key Laboratory of Power Transmission Equipment Technology, School of Electrical Engineering, Chongqing University, Chongqing 400044, China
1 shared publication - Niancheng Zhou
State Key Laboratory of Power Transmission Equipment Technology, Chongqing University, Chongqing 400044, China
1 shared publication - Qianggang Wang
Chongqing University
1 shared publication
Latest Publications
- Open Access
- 13 February 2026
- Published by MDPI AG in Applied Sciences
- Vol. 16 (4) , 1868
A Hybrid Current Source Converter-Based HVDC System with Power Coordination Control for Enhanced Reactive Power Support
HVDC technologies based on fully controlled devices offer numerous technical advantages, such as flexible active and reactive power control and black-start capability, making them highly promising for large-scale renewable energy integration and long-distance power transmission. However, their widespread adoption is constrained by high costs and significant power losses. Unlike existing hybrid HVDC schemes predominantly based on LCC-MMC structures, this paper proposes a novel hybrid current source converter-based HVDC (HCSC-HVDC) topology composed of IGCTs and thyristors, which enables power decoupling and achieves an approximate 70.5% reduction in high-voltage capacitor requirements, fundamentally improving system economy and structural efficiency. Firstly, the topological structure of the HCSC is introduced and a mathematical model is established. Then, the power operating range of the hybrid converter is quantitatively analyzed, and an optimization method for AC filter parameters is derived, based on which a power decoupling control strategy and a reactive power coordination control (RPCC) strategy are proposed. Finally, PSCAD electromagnetic transient simulations verify the effectiveness and feasibility of the proposed topology and control methods.
- 13 February 2026
- Published by MDPI AG in Applied Sciences
- Vol. 16 (4) , 1868
Open AccessA Hybrid Current Source Converter-Based HVDC System with Power Coordination Control for Enhanced Reactive Power Support
HVDC technologies based on fully controlled devices offer numerous technical advantages, such as flexible active and reactive power control and black-start capability, making them highly promising for large-scale renewable energy integration and long-distance power transmission. However, their widespread adoption is constrained by high costs and significant power losses. Unlike existing hybrid HVDC schemes predominantly based on LCC-MMC structures, this paper proposes a novel hybrid current source converter-based HVDC (HCSC-HVDC) topology composed of IGCTs and thyristors, which enables power decoupling and achieves an approximate 70.5% reduction in high-voltage capacitor requirements, fundamentally improving system economy and structural efficiency. Firstly, the topological structure of the HCSC is introduced and a mathematical model is established. Then, the power operating range of the hybrid converter is quantitatively analyzed, and an optimization method for AC filter parameters is derived, based on which a power decoupling control strategy and a reactive power coordination control (RPCC) strategy are proposed. Finally, PSCAD electromagnetic transient simulations verify the effectiveness and feasibility of the proposed topology and control methods.
- Open Access
Fault Section Identification for Hybrid Transmission Lines Considering the Weak-Feed Characteristics of Floating Photovoltaic Power Plant Inverters
The overhead line (OHL)–cable hybrid transmission line, which connects floating photovoltaic (PV) power plants, needs to be considered regarding whether to block reclosing operations or not. However, due to the weak-feed characteristics of PV inverters, existing methods are difficult to apply in this scenario. This paper proposes a criterion for fault section identification in the transmission lines of floating PV power plants based on traveling wave power and the zero-sequence impedance angle. Firstly, the fault current characteristics of photovoltaic inverters under dual-vector control are analyzed, and the applicability of the sequence component impedance directional criterion in this scenario is discussed. Then, the transmission, refraction, and reflection processes of traveling waves in OHL–cable hybrid lines are analyzed, and a traveling wave energy criterion is designed to determine the fault section. Finally, based on the scope of application of the zero-sequence impedance angle and traveling wave energy criterion, a fault section identification method for the hybrid lines of floating PV power plants is established. A deployment method for the proposed method, based on feeder terminal units (FTUs) at the connection points between the OHL and cable is proposed. This method identifies fault sections through traveling waves and zero-sequence impedance angles, which are unaffected by PV week feed characteristics, can be applied to all the AC fault types, and do not rely on multi-terminal synchronous sampling. The proposed method is verified on a 1MW PV system built in the PSCAD.
Open AccessFault Section Identification for Hybrid Transmission Lines Considering the Weak-Feed Characteristics of Floating Photovoltaic Power Plant Inverters
The overhead line (OHL)–cable hybrid transmission line, which connects floating photovoltaic (PV) power plants, needs to be considered regarding whether to block reclosing operations or not. However, due to the weak-feed characteristics of PV inverters, existing methods are difficult to apply in this scenario. This paper proposes a criterion for fault section identification in the transmission lines of floating PV power plants based on traveling wave power and the zero-sequence impedance angle. Firstly, the fault current characteristics of photovoltaic inverters under dual-vector control are analyzed, and the applicability of the sequence component impedance directional criterion in this scenario is discussed. Then, the transmission, refraction, and reflection processes of traveling waves in OHL–cable hybrid lines are analyzed, and a traveling wave energy criterion is designed to determine the fault section. Finally, based on the scope of application of the zero-sequence impedance angle and traveling wave energy criterion, a fault section identification method for the hybrid lines of floating PV power plants is established. A deployment method for the proposed method, based on feeder terminal units (FTUs) at the connection points between the OHL and cable is proposed. This method identifies fault sections through traveling waves and zero-sequence impedance angles, which are unaffected by PV week feed characteristics, can be applied to all the AC fault types, and do not rely on multi-terminal synchronous sampling. The proposed method is verified on a 1MW PV system built in the PSCAD.