Bader Almagren
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Bader Almagren has a total of 13 co-authors. Here are the top co-authors by number of shared publications:
- Ali Almustanyir
Optometry Department, College of Applied Medical Sciences, King Saud University, Riyadh 11362, Saudi Arabia
2 shared publications - Balsam Alabdulkader
Optometry Department, College of Applied Medical Sciences, King Saud University, Riyadh 11362, Saudi Arabia
2 shared publications - Tahani Alqahtani
Optometry Department, College of Applied Medical Sciences, King Saud University, Riyadh 11362, Saudi Arabia
2 shared publications - Abdulmalik Alhadyani
Department of Optometry, College of Applied Medical Sciences, King Saud University, Riyadh 11451, Saudi Arabia
1 shared publication - Amal Aldarwesh
Optometry Department, College of Applied Medical Sciences, King Saud University, Riyadh 11362, Saudi Arabia
1 shared publication - Essam Almutleb
Optometry Department, College of Applied Medical Sciences, King Saud University, Riyadh 11362, Saudi Arabia
1 shared publication
Latest Publications
- Open Access
Functional Outcomes with ChromaGen Filters in Red–Green Color Vision Deficiency: D-15 Arrangement Accuracy and Contrast Sensitivity
Colored filters alter the spectral composition of incident light reaching the retina and may influence performance on clinical color vision tests. This study evaluated the effects of three ChromaGen filters (magenta, pink, and violet) on Farnsworth D-15 arrangement performance and contrast sensitivity in individuals with congenital red–green color vision deficiency. Seventy-nine male participants with protan and deutan defects, classified using anomaloscopy, completed D-15 testing with Color Difference Vector analysis and contrast sensitivity assessment with Pelli–Robson chart under four conditions: no filter, magenta lens, pink lens, and violet lens. All three ChromaGen lenses were associated with significant reductions in confusion index (Cohen’s dz = 0.57–0.76) and total error score (Cohen’s dz = 0.58–0.81) compared with the no-filter condition, indicating improved performance on the D-15 arrangement task, with lens-specific effects. All lenses significantly reduced crossing errors (Wilcoxon r = 0.51–0.65), while transposition rates remained unchanged (χ2(3) = 3.11, p = 0.37). Pelli–Robson contrast sensitivity did not differ significantly between the no-filter and filter conditions (mean 1.92 logCS in all conditions). However, baseline scores were close to the test ceiling, and testing was limited to a single photopic luminance level and a single letter-chart format; therefore, this finding does not establish equivalence and should not be generalized to other luminance levels or spatial frequencies. Because the filters differed in luminous transmittance and no neutral-density control was included, a contribution of luminance-mediated cues to the D-15 improvements cannot be excluded. ChromaGen filters were associated with improved D-15 arrangement performance under the study conditions; the underlying chromatic and luminance mechanisms remain to be established.
Open AccessFunctional Outcomes with ChromaGen Filters in Red–Green Color Vision Deficiency: D-15 Arrangement Accuracy and Contrast Sensitivity
Colored filters alter the spectral composition of incident light reaching the retina and may influence performance on clinical color vision tests. This study evaluated the effects of three ChromaGen filters (magenta, pink, and violet) on Farnsworth D-15 arrangement performance and contrast sensitivity in individuals with congenital red–green color vision deficiency. Seventy-nine male participants with protan and deutan defects, classified using anomaloscopy, completed D-15 testing with Color Difference Vector analysis and contrast sensitivity assessment with Pelli–Robson chart under four conditions: no filter, magenta lens, pink lens, and violet lens. All three ChromaGen lenses were associated with significant reductions in confusion index (Cohen’s dz = 0.57–0.76) and total error score (Cohen’s dz = 0.58–0.81) compared with the no-filter condition, indicating improved performance on the D-15 arrangement task, with lens-specific effects. All lenses significantly reduced crossing errors (Wilcoxon r = 0.51–0.65), while transposition rates remained unchanged (χ2(3) = 3.11, p = 0.37). Pelli–Robson contrast sensitivity did not differ significantly between the no-filter and filter conditions (mean 1.92 logCS in all conditions). However, baseline scores were close to the test ceiling, and testing was limited to a single photopic luminance level and a single letter-chart format; therefore, this finding does not establish equivalence and should not be generalized to other luminance levels or spatial frequencies. Because the filters differed in luminous transmittance and no neutral-density control was included, a contribution of luminance-mediated cues to the D-15 improvements cannot be excluded. ChromaGen filters were associated with improved D-15 arrangement performance under the study conditions; the underlying chromatic and luminance mechanisms remain to be established.
- Open Access
- 13 November 2024
- Published by MDPI AG in Healthcare
- Vol. 12 (22) , 2262
Response of Patients with Color Vision Defects to Worth 4-Dot and Duochrome Tests
Background: Individuals with congenital color vision defects (CVDs) are at greater risk of misidentifying colors, necessitating an investigation into their ability to distinguish colors accurately. This study aimed to assess how individuals with CVDs perceive the colors in the Worth four-dot (W4D) and duochrome tests. It also explored whether individuals with CVDs require more detailed instructions from optometrists and eye care providers during these tests. Method: Thirty-two participants with congenital CVDs were recruited for this study. Participants with ocular diseases were excluded based on a brief questionnaire. The participants underwent a W4D test to determine the colors of four circles and the duochrome test without using filters. Result: All the participants correctly identified the W4D colors, except for five participants (15.62%). Furthermore, among all the participants, two (one with deuteranopia and one with protanopia) failed to identify the colors correctly in the duochrome test (6.25%). Conclusions: The findings suggest that in the context of optometric assessment, it could be essential for optometrists to incorporate a preliminary inquiry into a patient’s ability to identify colors prior to performing diagnostic tests such as the W4D or duochrome tests. Incorrect responses from patients with CVDs might mislead optometrists regarding the proper outcomes of the test.
- 13 November 2024
- Published by MDPI AG in Healthcare
- Vol. 12 (22) , 2262
Open AccessResponse of Patients with Color Vision Defects to Worth 4-Dot and Duochrome Tests
Background: Individuals with congenital color vision defects (CVDs) are at greater risk of misidentifying colors, necessitating an investigation into their ability to distinguish colors accurately. This study aimed to assess how individuals with CVDs perceive the colors in the Worth four-dot (W4D) and duochrome tests. It also explored whether individuals with CVDs require more detailed instructions from optometrists and eye care providers during these tests. Method: Thirty-two participants with congenital CVDs were recruited for this study. Participants with ocular diseases were excluded based on a brief questionnaire. The participants underwent a W4D test to determine the colors of four circles and the duochrome test without using filters. Result: All the participants correctly identified the W4D colors, except for five participants (15.62%). Furthermore, among all the participants, two (one with deuteranopia and one with protanopia) failed to identify the colors correctly in the duochrome test (6.25%). Conclusions: The findings suggest that in the context of optometric assessment, it could be essential for optometrists to incorporate a preliminary inquiry into a patient’s ability to identify colors prior to performing diagnostic tests such as the W4D or duochrome tests. Incorrect responses from patients with CVDs might mislead optometrists regarding the proper outcomes of the test.