Gabriel Rabanal-Rodríguez
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Gabriel Rabanal-Rodríguez has a total of 32 co-authors. Here are the top co-authors by number of shared publications:
- Gustavo Plaza-Manzano
Department of Physiotherapy, Faculty of Nursing, Physiotherapy and Podiatry, Complutense University of Madrid, 28040 Madrid, Spain; Grupo InPhysio, Instituto de Investigación Sanitaria del Hospital Clínico San Carlos (IdISSC), 28040 Madrid, Spain
8 shared publications - Marcos José Navarro-Santana
Department of Physiotherapy, Faculty of Nursing, Physiotherapy and Podiatry, Complutense University of Madrid, 28040 Madrid, Spain; Grupo InPhysio, Instituto de Investigación Sanitaria del Hospital Clínico San Carlos (IdISSC), 28040 Madrid, Spain
8 shared publications - Juan Antonio Valera-Calero
Department of Physiotherapy, Universidad Complutense de Madrid, 28040 Madrid, Spain
7 shared publications - Carlos Romero-Morales
Department of Physiotherapy, Faculty of Medicine, Health and Sports, European University of Madrid, Villaviciosa de Odón, 28670 Madrid, Spain
3 shared publications - César Fernández-De-Las-Peñas
Department of Physical Therapy, Occupational Therapy, Physical Medicine and Rehabilitation, Universidad Rey Juan Carlos, 28922 Alcorcón, Spain
3 shared publications - Guido Fabián Gómez-Chiguano
Clínica Campos. 03540 Alicante, Spain
3 shared publications
Latest Publications
- 16 July 2026
- Published by Elsevier in Archives of Physical Medicine and Rehabilitation
- Vol. 107 (11) , 3279-3289
Long-Term Benefits of Ultrasound-Guided Percutaneous Electrical Nerve Stimulation for Chronic Lateral Elbow Pain: A Randomized Controlled Trial
- 16 July 2026
- Published by Elsevier in Archives of Physical Medicine and Rehabilitation
- Vol. 107 (11) , 3279-3289
Long-Term Benefits of Ultrasound-Guided Percutaneous Electrical Nerve Stimulation for Chronic Lateral Elbow Pain: A Randomized Controlled Trial
- 11 May 2026
- Published by Taylor & Francis in Physiotherapy Theory and Practice
- p. 1-10
Nonoperative treatment of an anterior Achilles partial tear with load management and percutaneous electrolysis in an amateur basketball player. One year follow-up
Partial tears of the Achilles tendon, particularly those affecting the anterior fibers, are relatively uncommon and often underdiagnosed (Gatz, Spang, and Alfredson, 2020; Śmigielski, 2008). Clinic...
- 11 May 2026
- Published by Taylor & Francis in Physiotherapy Theory and Practice
- p. 1-10
Nonoperative treatment of an anterior Achilles partial tear with load management and percutaneous electrolysis in an amateur basketball player. One year follow-up
Partial tears of the Achilles tendon, particularly those affecting the anterior fibers, are relatively uncommon and often underdiagnosed (Gatz, Spang, and Alfredson, 2020; Śmigielski, 2008). Clinic...
- Open Access
Testing the Reliability of a Procedure Using Shear-Wave Elastography for Measuring Longus Colli Muscle Stiffness
Background: Objective, reproducible assessment of deep cervical muscle mechanics is clinically relevant, yet the reliability of shear-wave elastography (SWE) for the longus colli (LC) has not been established. Therefore, the aim of this study was to determine intra- and inter-examiner reliability of LC stiffness measured by SWE under a tightly standardized protocol in patients with mechanical neck pain. Methods: A longitudinal reliability study was conducted. Adults suffering from neck pain for ≥6 months were recruited. Two examiners (with different levels of experience) acquired bilateral LC images using fixed presets. The SWE region of interest covered the full muscle thickness (excluding fascia) to measure the LC shear-wave speed and Young’s modulus. Intraclass correlation coefficients (ICCs), standard error of measurement and minimal detectable changes were computed. Results: Nineteen participants with neck pain completed imaging (left and right sides analyzed). Inter-examiner agreement was good to excellent for single measurements (ICC3,2 > 0.818) and improved when averaging two acquisitions (ICC3,2 > 0.866). Intra-examiner repeatability was good to excellent for the novel examiner (ICC3,1 > 0.891) and excellent for the experienced examiner (ICC3,1 > 0.973). No meaningful stiffness differences by sex or side were observed in this sample (p > 0.05). Conclusions: A standardized SWE workflow yields reproducible LC stiffness measurements in mechanical neck pain. For longitudinal use, keep a single operator when feasible; in multi-examiner settings, average at least two acquisitions per side to enhance sensitivity to true change.
Open AccessTesting the Reliability of a Procedure Using Shear-Wave Elastography for Measuring Longus Colli Muscle Stiffness
Background: Objective, reproducible assessment of deep cervical muscle mechanics is clinically relevant, yet the reliability of shear-wave elastography (SWE) for the longus colli (LC) has not been established. Therefore, the aim of this study was to determine intra- and inter-examiner reliability of LC stiffness measured by SWE under a tightly standardized protocol in patients with mechanical neck pain. Methods: A longitudinal reliability study was conducted. Adults suffering from neck pain for ≥6 months were recruited. Two examiners (with different levels of experience) acquired bilateral LC images using fixed presets. The SWE region of interest covered the full muscle thickness (excluding fascia) to measure the LC shear-wave speed and Young’s modulus. Intraclass correlation coefficients (ICCs), standard error of measurement and minimal detectable changes were computed. Results: Nineteen participants with neck pain completed imaging (left and right sides analyzed). Inter-examiner agreement was good to excellent for single measurements (ICC3,2 > 0.818) and improved when averaging two acquisitions (ICC3,2 > 0.866). Intra-examiner repeatability was good to excellent for the novel examiner (ICC3,1 > 0.891) and excellent for the experienced examiner (ICC3,1 > 0.973). No meaningful stiffness differences by sex or side were observed in this sample (p > 0.05). Conclusions: A standardized SWE workflow yields reproducible LC stiffness measurements in mechanical neck pain. For longitudinal use, keep a single operator when feasible; in multi-examiner settings, average at least two acquisitions per side to enhance sensitivity to true change.
- Open Access
- 9 October 2025
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 20 (10) , e0330076
Shear Wave Elastography for measuring the elastic properties of the Psoas Major muscle: An intra- and inter-examiner reliability study
Background: The psoas major (PM) plays an important role in population with low back pain (LBP). Its evaluation considers clinical history, which can be confused with other lumbar and lower limb conditions, physical examination, with an inconsistent palpation, and imaging tests that provide inconclusive parameters in various studies. Therefore, developing reliable assessment procedures to evaluate PM elastic properties is necessary to improve diagnosis and follow-up. This study aimed to evaluate the intra and inter-examiner reliability of shear wave elastography (SWE) for calculating the PM stiffness in patients with LBP. Design: Observational study. Methods: Longitudinal views of the of the PM muscle using SWE were acquired bilaterally in 52 volunteers experiencing moderate LBP and disability. All measurements were performed twice, involving the assessment of shear wave speed and Young’s modulus as indicators of stiffness, with data collected by an experienced examiner and a novice examiner. Results: Test-retest reliability showed strong consistency regardless of the examiner’s level of experience, with intraclass correlation coefficients (ICCs) exceeding 0.9 for both metrics. However, experienced examiners achieved smaller minimal detectable changes. Inter-examiner reliability was comparatively lower, with ICCs ranging from 0.854 to 0.925, and notable differences in mean values between examiners were observed (p < 0.01). Conclusion: Excellent test-retest reliability was observed for the measurement of PM muscle stiffness in chronic LBP patients using SWE by both experienced and novice evaluators, although statistically significant differences were found between the two trials for the novice examiner. Inter-examiner reliability was lower, highlighting variability between assessors. To minimize errors and improve consistency and accuracy, if multiple examiners are involved, averaging measurements is recommended.
- 9 October 2025
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 20 (10) , e0330076
Open AccessShear Wave Elastography for measuring the elastic properties of the Psoas Major muscle: An intra- and inter-examiner reliability study
Background: The psoas major (PM) plays an important role in population with low back pain (LBP). Its evaluation considers clinical history, which can be confused with other lumbar and lower limb conditions, physical examination, with an inconsistent palpation, and imaging tests that provide inconclusive parameters in various studies. Therefore, developing reliable assessment procedures to evaluate PM elastic properties is necessary to improve diagnosis and follow-up. This study aimed to evaluate the intra and inter-examiner reliability of shear wave elastography (SWE) for calculating the PM stiffness in patients with LBP. Design: Observational study. Methods: Longitudinal views of the of the PM muscle using SWE were acquired bilaterally in 52 volunteers experiencing moderate LBP and disability. All measurements were performed twice, involving the assessment of shear wave speed and Young’s modulus as indicators of stiffness, with data collected by an experienced examiner and a novice examiner. Results: Test-retest reliability showed strong consistency regardless of the examiner’s level of experience, with intraclass correlation coefficients (ICCs) exceeding 0.9 for both metrics. However, experienced examiners achieved smaller minimal detectable changes. Inter-examiner reliability was comparatively lower, with ICCs ranging from 0.854 to 0.925, and notable differences in mean values between examiners were observed (p < 0.01). Conclusion: Excellent test-retest reliability was observed for the measurement of PM muscle stiffness in chronic LBP patients using SWE by both experienced and novice evaluators, although statistically significant differences were found between the two trials for the novice examiner. Inter-examiner reliability was lower, highlighting variability between assessors. To minimize errors and improve consistency and accuracy, if multiple examiners are involved, averaging measurements is recommended.
- 6 September 2025
- Published by Elsevier in Archives of Physical Medicine and Rehabilitation
- Vol. 107 (2) , 299-314
Neurophysiological Effects of Dry Needling: A Systematic Review and Meta-analysis
- 6 September 2025
- Published by Elsevier in Archives of Physical Medicine and Rehabilitation
- Vol. 107 (2) , 299-314
Neurophysiological Effects of Dry Needling: A Systematic Review and Meta-analysis
- Open Access
- 3 September 2025
- Published by Springer Nature in Research Square
Exploration of symptomatic responses to the straight leg raise test and efficacy of sciatic nerve electrical stimulation in the management of low-back related leg pain: a study protocol.
Low back pain, with or without leg irradiation, is one of the leading causes of musculoskeletal disability, with significant clinical and socioeconomic implications. Despite the availability of multiple therapeutic approaches, evidence regarding the most effective strategy remains limited, particularly for conservative interventions.This project integrates two complementary studies. The first, an observational study, will assess the diagnostic utility of the straight leg raise test to distinguish between different clinical presentations of low back pain (localized/nociceptive vs. irradiated/neuropathic) and healthy individuals, by analyzing symptomatic responses during the test.The second is a randomized clinical trial comparing the efficacy of percutaneous electrical nerve stimulation (PENS) versus transcutaneous electrical nerve stimulation (TENS) and placebo, all in combination with a therapeutic exercise program, to improve pain, disability and physical function in patients with neuropathic-like low-back related leg pain. The interventions will be delivered over six weeks, with assessments conducted at baseline, after the first session, after one week, at the end of treatment and at 3- and 6-months post-intervention.This project will help define the diagnostic value of the straight leg raise test and provide clinical evidence regarding percutaneous and transcutaneous electrical stimulation in physiotherapy, contributing to the optimization of conservative treatment strategies for neuropathic-like low-back related leg pain.
- 3 September 2025
- Published by Springer Nature in Research Square
Open AccessExploration of symptomatic responses to the straight leg raise test and efficacy of sciatic nerve electrical stimulation in the management of low-back related leg pain: a study protocol.
Low back pain, with or without leg irradiation, is one of the leading causes of musculoskeletal disability, with significant clinical and socioeconomic implications. Despite the availability of multiple therapeutic approaches, evidence regarding the most effective strategy remains limited, particularly for conservative interventions.This project integrates two complementary studies. The first, an observational study, will assess the diagnostic utility of the straight leg raise test to distinguish between different clinical presentations of low back pain (localized/nociceptive vs. irradiated/neuropathic) and healthy individuals, by analyzing symptomatic responses during the test.The second is a randomized clinical trial comparing the efficacy of percutaneous electrical nerve stimulation (PENS) versus transcutaneous electrical nerve stimulation (TENS) and placebo, all in combination with a therapeutic exercise program, to improve pain, disability and physical function in patients with neuropathic-like low-back related leg pain. The interventions will be delivered over six weeks, with assessments conducted at baseline, after the first session, after one week, at the end of treatment and at 3- and 6-months post-intervention.This project will help define the diagnostic value of the straight leg raise test and provide clinical evidence regarding percutaneous and transcutaneous electrical stimulation in physiotherapy, contributing to the optimization of conservative treatment strategies for neuropathic-like low-back related leg pain.
- Open Access
- 23 March 2025
- Published by Elsevier in Musculoskeletal Science and Practice
- Vol. 77, 103317
Diagnostic accuracy of neurodynamic tests in upper-limb entrapment neuropathies: A systematic review and meta-analysis
- 23 March 2025
- Published by Elsevier in Musculoskeletal Science and Practice
- Vol. 77, 103317
Open AccessDiagnostic accuracy of neurodynamic tests in upper-limb entrapment neuropathies: A systematic review and meta-analysis
- Open Access
Association of Quadratus Lumborum Muscle Stiffness with Chronic Low Back Pain Features: An Observational Study
Background and Objectives: Low back pain (LBP) is highly prevalent and often associated with altered muscle function, including in the quadratus lumborum (QL) muscle. While some studies have highlighted the clinical relevance of QL muscle stiffness in LBP, the findings remain inconsistent, and the role of this parameter in relation to clinical severity indicators is not well understood. Considering the high prevalence of myofascial trigger points among patients, objectively and reliably quantifying QL stiffness and its association with other clinical parameters could improve the identification of early stages of the condition before other alterations become apparent. Therefore, this study aimed to explore the association between QL stiffness and multiple indicators of LBP severity. Materials and Methods: A cross-sectional observational study was conducted involving the participation of seventy-six patients suffering from chronic LBP. An ultrasound scanner with shear-wave elastography (SWE) was used to determine the participants’ QL stiffness. Additional information was collected on LBP-associated pain intensity, disability, central sensitization, and quality of life. Results: QL muscle stiffness was negatively correlated with pain intensity (p < 0.01) and central sensitization (p < 0.01), and it was positively correlated with physical quality of life (p < 0.01). Muscle stiffness influenced the variance in pain intensity along with physical quality of life, central sensitization, and chronicity (together explaining 49% of the variance) but did not explain the variance in central sensitization. Conclusions: Assessing QL muscle stiffness in patients with LBP is recommended, as greater muscle softness is linked to higher pain intensity, central sensitization, and poorer physical quality of life. Regression analyses further highlighted that QL stiffness helps explain the variance in pain intensity, physical quality of life, central sensitization, and chronicity, but it did not directly affect the central sensitization variance.
Open AccessAssociation of Quadratus Lumborum Muscle Stiffness with Chronic Low Back Pain Features: An Observational Study
Background and Objectives: Low back pain (LBP) is highly prevalent and often associated with altered muscle function, including in the quadratus lumborum (QL) muscle. While some studies have highlighted the clinical relevance of QL muscle stiffness in LBP, the findings remain inconsistent, and the role of this parameter in relation to clinical severity indicators is not well understood. Considering the high prevalence of myofascial trigger points among patients, objectively and reliably quantifying QL stiffness and its association with other clinical parameters could improve the identification of early stages of the condition before other alterations become apparent. Therefore, this study aimed to explore the association between QL stiffness and multiple indicators of LBP severity. Materials and Methods: A cross-sectional observational study was conducted involving the participation of seventy-six patients suffering from chronic LBP. An ultrasound scanner with shear-wave elastography (SWE) was used to determine the participants’ QL stiffness. Additional information was collected on LBP-associated pain intensity, disability, central sensitization, and quality of life. Results: QL muscle stiffness was negatively correlated with pain intensity (p < 0.01) and central sensitization (p < 0.01), and it was positively correlated with physical quality of life (p < 0.01). Muscle stiffness influenced the variance in pain intensity along with physical quality of life, central sensitization, and chronicity (together explaining 49% of the variance) but did not explain the variance in central sensitization. Conclusions: Assessing QL muscle stiffness in patients with LBP is recommended, as greater muscle softness is linked to higher pain intensity, central sensitization, and poorer physical quality of life. Regression analyses further highlighted that QL stiffness helps explain the variance in pain intensity, physical quality of life, central sensitization, and chronicity, but it did not directly affect the central sensitization variance.
- Open Access
- 31 January 2025
- Published by MDPI AG in Applied Sciences
- Vol. 15 (3) , 1452
Intra- and Inter-Examiner Reliability of Kinovea for Hip Flexion Angle Measurement During Straight Leg Raise Test
The accurate and reliable measurement of hip flexion angles during the Straight Leg Raise (SLR) test is essential for clinical and research purposes. Despite the widespread use of motion analysis tools, few studies have examined the reliability of affordable, open-source software 0.9.5 like Kinovea for this application. This study aimed to evaluate the intra- and inter-examiner reliability of Kinovea for measuring the hip flexion angle during the SLR test in individuals with and without low back pain (LBP). An observational study was conducted involving 53 participants (38 with LBP and 15 asymptomatic controls). Each participant underwent two SLR test sessions conducted by two examiners with varying levels of experience. The hip flexion angles were measured using Kinovea software based on video recordings. Intra- and inter-examiner reliability were assessed using the Intraclass Correlation Coefficient (ICC), Standard Error of Measurement (SEM), and Minimal Detectable Change (MDC). The effects of examiner experience and patient group were also analyzed. Kinovea demonstrated excellent intra- and inter-examiner reliability for measuring hip flexion angles, with ICC values ranging from 0.985 to 0.998. The SEM values were low (0.5°–1.5°), and the MDC values at 95% confidence ranged from 1.3° to 4.0°. No significant differences were found between the examiners’ experience or the patient groups. Thus, Kinovea offers a reliable, cost-effective, and user-friendly method for measuring hip flexion angles during the SLR test. Its consistency and precision, even across examiners with differing experience levels, highlight its potential to standardize assessments and improve diagnostic and therapeutic applications. Future research should explore its use in more complex movement analyses and diverse clinical populations to further validate its utility.
- 31 January 2025
- Published by MDPI AG in Applied Sciences
- Vol. 15 (3) , 1452
Open AccessIntra- and Inter-Examiner Reliability of Kinovea for Hip Flexion Angle Measurement During Straight Leg Raise Test
The accurate and reliable measurement of hip flexion angles during the Straight Leg Raise (SLR) test is essential for clinical and research purposes. Despite the widespread use of motion analysis tools, few studies have examined the reliability of affordable, open-source software 0.9.5 like Kinovea for this application. This study aimed to evaluate the intra- and inter-examiner reliability of Kinovea for measuring the hip flexion angle during the SLR test in individuals with and without low back pain (LBP). An observational study was conducted involving 53 participants (38 with LBP and 15 asymptomatic controls). Each participant underwent two SLR test sessions conducted by two examiners with varying levels of experience. The hip flexion angles were measured using Kinovea software based on video recordings. Intra- and inter-examiner reliability were assessed using the Intraclass Correlation Coefficient (ICC), Standard Error of Measurement (SEM), and Minimal Detectable Change (MDC). The effects of examiner experience and patient group were also analyzed. Kinovea demonstrated excellent intra- and inter-examiner reliability for measuring hip flexion angles, with ICC values ranging from 0.985 to 0.998. The SEM values were low (0.5°–1.5°), and the MDC values at 95% confidence ranged from 1.3° to 4.0°. No significant differences were found between the examiners’ experience or the patient groups. Thus, Kinovea offers a reliable, cost-effective, and user-friendly method for measuring hip flexion angles during the SLR test. Its consistency and precision, even across examiners with differing experience levels, highlight its potential to standardize assessments and improve diagnostic and therapeutic applications. Future research should explore its use in more complex movement analyses and diverse clinical populations to further validate its utility.