Bingheng Yan
Bingheng Yan has a total of 32 co-authors. Here are the top co-authors by number of shared publications:
- Dong Zhang
Inspur Data Technology Co, Ltd, Jinan, Shandong, China
4 shared publications - Fangming Liu
Huazhong University of Science and Technology, Wuhan, China
3 shared publications - Qiangyu Pei
National Engineering Research Center for Big Data Technology and System, Services Computing Technology and System Lab, Cluster and Grid Computing Lab, School of Computer Science and Technology, Huazhong University of Science and Technology, Wuhan, China
3 shared publications - Chen Yu
School of Computer Science and Technology, Huazhong University of Science and Technology, Wuhan, China
2 shared publications - Lin Wang
Paderborn University, Paderborn, Germany
2 shared publications - Ahmed Mohamed Abdelmoniem
Queen Mary University of London
1 shared publication
Latest Publications
- 14 January 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Computers
- Vol. 75 (4) , 1518-1532
Cooling as You Wish: Component-Level Cooling for Heterogeneous Edge Datacenters
As computing shifts toward the edge, edge datacenters are becoming essential for supporting diverse real-time applications. Unlike traditional cloud datacenters, edge datacenters face unique cooling challenges due to their requirements for proximity to end users, high density, and hardware heterogeneity. While warm water cooling is a promising technique for this infrastructure, current one-size-fits-all cooling strategies significantly compromise efficiency due to severe inter- and intra-component hotspots. In this work, we present CoolEdge${}^{+}$ , a cost-effective component-level water cooling system for enhancing the cooling efficiency of edge datacenters. Specifically, CoolEdge${}^{+}$ dynamically adjusts the inlet water temperature for each component through a carefully designed water circulation architecture to mitigate inter-component hotspots. To address intra-component hotspots, it employs vapor chamber–based cold plates that rapidly dissipate heat without manual intervention or additional energy consumption. We further design a fine-grained cooling control framework that leverages a well-managed power capping approach to decide on customized inlet water temperatures and hardware power limits. Based on a hardware prototype and a real-world trace from Alibaba PAI, evaluation results show that CoolEdge${}^{+}$ reduces cooling energy consumption by up to 27.19% compared to existing coarse-grained systems, while maintaining performance guarantees. Compared to the state-of-the-art CoolEdge, CoolEdge${}^{+}$ saves 35.24% more cooling costs with comparable energy consumption and no latency violations.- 14 January 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Computers
- Vol. 75 (4) , 1518-1532
Cooling as You Wish: Component-Level Cooling for Heterogeneous Edge Datacenters
As computing shifts toward the edge, edge datacenters are becoming essential for supporting diverse real-time applications. Unlike traditional cloud datacenters, edge datacenters face unique cooling challenges due to their requirements for proximity to end users, high density, and hardware heterogeneity. While warm water cooling is a promising technique for this infrastructure, current one-size-fits-all cooling strategies significantly compromise efficiency due to severe inter- and intra-component hotspots. In this work, we present CoolEdge${}^{+}$ , a cost-effective component-level water cooling system for enhancing the cooling efficiency of edge datacenters. Specifically, CoolEdge${}^{+}$ dynamically adjusts the inlet water temperature for each component through a carefully designed water circulation architecture to mitigate inter-component hotspots. To address intra-component hotspots, it employs vapor chamber–based cold plates that rapidly dissipate heat without manual intervention or additional energy consumption. We further design a fine-grained cooling control framework that leverages a well-managed power capping approach to decide on customized inlet water temperatures and hardware power limits. Based on a hardware prototype and a real-world trace from Alibaba PAI, evaluation results show that CoolEdge${}^{+}$ reduces cooling energy consumption by up to 27.19% compared to existing coarse-grained systems, while maintaining performance guarantees. Compared to the state-of-the-art CoolEdge, CoolEdge${}^{+}$ saves 35.24% more cooling costs with comparable energy consumption and no latency violations.- 23 September 2025
- Published by Elsevier in Computer Networks
- Vol. 272
Entangled qubit pricing for quantum networks
- 23 September 2025
- Published by Elsevier in Computer Networks
- Vol. 272
Entangled qubit pricing for quantum networks
- 19 February 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Networking
- Vol. 33 (4) , 1646-1659
Troubleshooting Programmable Data Planes via Real-Time Table Information Recording
While the flexibility of programmable switches brings opportunities, it also introduces security risks. Hence, it is vital to conduct effective troubleshooting in the programmable switch to mitigate frequent network failures. However, troubleshooting programmable switch failures is challenging due to their enhanced flexibility and functionality compared to regular switches, posing increased difficulty in debugging, particularly with limited debugging tools and information. To address this problem, we propose an efficient troubleshooting method that records real-time information about packets in the data plane, including the tables involved in packet processing. Unfortunately, due to hardware limitations, it is infeasible to record all tables’ information in the data plane. Thus, the key is to find the table set reflecting the execution path a packet goes through while minimizing the resource overhead. We first represent P4 programs as a probabilistic transition directed acyclic graph (DAG) and employ information entropy to quantify the information within a set of tracked tables. Then, we adopt a two-step approach and design algorithms to find both optimal and approximately optimal table record plans. The evaluation results show the efficacy of the proposed method, including achieving the same path recovery rate as the related works with less than one-third of the resource consumption.
- 19 February 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Networking
- Vol. 33 (4) , 1646-1659
Troubleshooting Programmable Data Planes via Real-Time Table Information Recording
While the flexibility of programmable switches brings opportunities, it also introduces security risks. Hence, it is vital to conduct effective troubleshooting in the programmable switch to mitigate frequent network failures. However, troubleshooting programmable switch failures is challenging due to their enhanced flexibility and functionality compared to regular switches, posing increased difficulty in debugging, particularly with limited debugging tools and information. To address this problem, we propose an efficient troubleshooting method that records real-time information about packets in the data plane, including the tables involved in packet processing. Unfortunately, due to hardware limitations, it is infeasible to record all tables’ information in the data plane. Thus, the key is to find the table set reflecting the execution path a packet goes through while minimizing the resource overhead. We first represent P4 programs as a probabilistic transition directed acyclic graph (DAG) and employ information entropy to quantify the information within a set of tracked tables. Then, we adopt a two-step approach and design algorithms to find both optimal and approximately optimal table record plans. The evaluation results show the efficacy of the proposed method, including achieving the same path recovery rate as the related works with less than one-third of the resource consumption.
- 17 February 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Sustainable Computing
- Vol. 10 (4) , 804-819
Working Smarter Not Harder: Hybrid Cooling for Deep Learning in Edge Datacenters
The proliferation of deep-learning-based mobile and IoT applications has driven the increasing deployment of edge datacenters equipped with domain-specific accelerators. The unprecedented computing power offered by these accelerators puts a heavy burden on the cooling system, motivating more potent cooling techniques like cold water cooling. However, we observe that cold water cooling results in significant energy waste in edge datacenters due to the fluctuating resource utilization both spatially and temporally. To tackle this issue, we propose the concept of “working smarter” by slowing down accelerators deliberately whenever possible and enabling warm water cooling during these times to achieve cooling efficiency. Based on this concept, we develop Hyco—a hybrid water cooling system tailored for edge datacenters running deep learning workloads. First, Hyco features a zone-based cooling architecture enabling dynamic switching between cold water and warm water cooling. Then, based on a lightweight latency estimation method, Hyco incorporates a learning-based scheduling scheme to determine “which” accelerator workers and “when” to slow down through an adaptive and intelligent power-latency trade-off for deep learning models. The simulation with real-world traces shows that Hyco reduces the cooling energy consumption by up to 34.74× while satisfying latency constraints more than 99% of the time for deep-learning-based applications.
- 17 February 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Sustainable Computing
- Vol. 10 (4) , 804-819
Working Smarter Not Harder: Hybrid Cooling for Deep Learning in Edge Datacenters
The proliferation of deep-learning-based mobile and IoT applications has driven the increasing deployment of edge datacenters equipped with domain-specific accelerators. The unprecedented computing power offered by these accelerators puts a heavy burden on the cooling system, motivating more potent cooling techniques like cold water cooling. However, we observe that cold water cooling results in significant energy waste in edge datacenters due to the fluctuating resource utilization both spatially and temporally. To tackle this issue, we propose the concept of “working smarter” by slowing down accelerators deliberately whenever possible and enabling warm water cooling during these times to achieve cooling efficiency. Based on this concept, we develop Hyco—a hybrid water cooling system tailored for edge datacenters running deep learning workloads. First, Hyco features a zone-based cooling architecture enabling dynamic switching between cold water and warm water cooling. Then, based on a lightweight latency estimation method, Hyco incorporates a learning-based scheduling scheme to determine “which” accelerator workers and “when” to slow down through an adaptive and intelligent power-latency trade-off for deep learning models. The simulation with real-world traces shows that Hyco reduces the cooling energy consumption by up to 34.74× while satisfying latency constraints more than 99% of the time for deep-learning-based applications.
- Open Access
- 20 November 2024
- Published by Association for Computing Machinery (ACM)
- p. 487-504
InferCool: Enhancing AI Inference Cooling through Transparent, Non-Intrusive Task Reassignment
The increasing power consumption of AI inference in modern datacenters has escalated cooling demands significantly, necessitating the adoption of potent cooling approaches like water cooling. Unlike traditional cloud workloads, AI inference has unique characteristics that create substantial gaps in achieving optimal cooling efficiency. In this work, we present the first comprehensive measurement study of AI inference cooling across various models within an industrial-ready scheduling framework, highlighting significant inefficiencies and their causes. To fill the gap while following the fundamental requirements of cooling systems, we explore a new opportunity presented by modern Multi-Instance GPU-enabled inference serving, where the scheduling dimension is naturally orthogonal to the cooling dimension. Building on this insight, we develop InferCool, a cooling middleware designed to enhance cooling efficiency for inference serving through transparent, non-intrusive task reassignment. It includes a streamlined power and temperature prediction approach and a thermal-aware, adaptive application deployment and request scheduling mechanism. Real-world experiments on a water-cooled testbed and a three-node cluster demonstrate that InferCool can reduce the maximum GPU temperature by 5°C across eight A100 GPUs, equivalent to cooling energy savings of about 20%. Importantly, InferCool requires no modifications to existing cooling infrastructures and is compatible with existing scheduling systems.
- 20 November 2024
- Published by Association for Computing Machinery (ACM)
- p. 487-504
Open AccessInferCool: Enhancing AI Inference Cooling through Transparent, Non-Intrusive Task Reassignment
The increasing power consumption of AI inference in modern datacenters has escalated cooling demands significantly, necessitating the adoption of potent cooling approaches like water cooling. Unlike traditional cloud workloads, AI inference has unique characteristics that create substantial gaps in achieving optimal cooling efficiency. In this work, we present the first comprehensive measurement study of AI inference cooling across various models within an industrial-ready scheduling framework, highlighting significant inefficiencies and their causes. To fill the gap while following the fundamental requirements of cooling systems, we explore a new opportunity presented by modern Multi-Instance GPU-enabled inference serving, where the scheduling dimension is naturally orthogonal to the cooling dimension. Building on this insight, we develop InferCool, a cooling middleware designed to enhance cooling efficiency for inference serving through transparent, non-intrusive task reassignment. It includes a streamlined power and temperature prediction approach and a thermal-aware, adaptive application deployment and request scheduling mechanism. Real-world experiments on a water-cooled testbed and a three-node cluster demonstrate that InferCool can reduce the maximum GPU temperature by 5°C across eight A100 GPUs, equivalent to cooling energy savings of about 20%. Importantly, InferCool requires no modifications to existing cooling infrastructures and is compatible with existing scheduling systems.