Carmen Pastor
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Carmen Pastor has a total of 61 co-authors. Here are the top co-authors by number of shared publications:
F. Le Guern
2 shared publications- Mercedes Medrano
CIEMAT, Lab Nacl Fus, Madrid 28040, Spain
2 shared publications - Raquel López Heredero
Instituto Nacional de Técnica Aeroespacial (Spain)
2 shared publications A. Jiménez-Denche
Laboratorio Nacional de Fusión-CIEMAT, Av. Complutense 40, 28040 Madrid, Spain
1 shared publicationA. Pereira
1 shared publicationA. Soleto
Laboratorio Nacional de Fusión-CIEMAT, Av. Complutense 40, 28040 Madrid, Spain
1 shared publication
Latest Publications
- Open Access
- 27 September 2025
- Published by Elsevier in Fusion Engineering and Design
- Vol. 222
Optical characterization of a full scale rhodium coated first mirror for ITER Wide Angle Viewing System (WAVS) diagnostic
- 27 September 2025
- Published by Elsevier in Fusion Engineering and Design
- Vol. 222
Open AccessOptical characterization of a full scale rhodium coated first mirror for ITER Wide Angle Viewing System (WAVS) diagnostic
- 1 November 2024
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 95 (11)
Design, justification, and prototyping of the visible and infrared wide angle viewing system diagnostic for ITER equatorial port 12
The ITER equatorial visible and infrared Wide Angle Viewing System (WAVS) will play a major role in the protection of plasma facing components by providing surface temperature measurements of these components. It will also image the plasma emission in the visible range. The WAVS is composed of 15 lines of sight located in four Equatorial Ports (EPs) 3, 9, 12, and 17. Its development is being carried out by the Consortium constituted by CEA, CIEMAT, INTA, and Bertin Technologies, within grant contracts financed by F4E. In the EP12, the in-vessel and ex-vessel components of the WAVS are at their final design phase. This article presents an overview of the opto-mechanical design of the WAVS in the EP12 presented at the final design review.
- 1 November 2024
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 95 (11)
Design, justification, and prototyping of the visible and infrared wide angle viewing system diagnostic for ITER equatorial port 12
The ITER equatorial visible and infrared Wide Angle Viewing System (WAVS) will play a major role in the protection of plasma facing components by providing surface temperature measurements of these components. It will also image the plasma emission in the visible range. The WAVS is composed of 15 lines of sight located in four Equatorial Ports (EPs) 3, 9, 12, and 17. Its development is being carried out by the Consortium constituted by CEA, CIEMAT, INTA, and Bertin Technologies, within grant contracts financed by F4E. In the EP12, the in-vessel and ex-vessel components of the WAVS are at their final design phase. This article presents an overview of the opto-mechanical design of the WAVS in the EP12 presented at the final design review.
- 1 September 2019
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 14 (09) , C09028
New infrared imaging diagnostic for the Neutral Beam Heating System at the TJ-II stellarator
An upgraded infrared imaging system has been installed at the stellarator TJ-II as a diagnostic tool of the Neutral Beam Injection heating. Thermographic analysis of the beam-wall interaction areas can be used to estimate the beam power lost through reionization and shine-through mechanisms in Neutral Beam heated plasmas. Three different Regions of Interest inside TJ-II vacuum vessel have been determined whose thermographic analysis will be applied to the study of beam related processes. The optical conditions required for each application have been used to define the specifications of the IR camera. Optimization of the optical design has been carried out by means of the optical simulation code ZEMAX. The IR window size has been increased to maximize the fraction of the field of view that is free from vignetting. The system has been fully commissioned and is now operative, routinely providing thermographic data of the regions of interest during the last TJ-II experimental campaign. The IR diagnostic is described in detail and its applicability to study beam power deposition on different targets is discussed.
- 1 September 2019
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 14 (09) , C09028
New infrared imaging diagnostic for the Neutral Beam Heating System at the TJ-II stellarator
An upgraded infrared imaging system has been installed at the stellarator TJ-II as a diagnostic tool of the Neutral Beam Injection heating. Thermographic analysis of the beam-wall interaction areas can be used to estimate the beam power lost through reionization and shine-through mechanisms in Neutral Beam heated plasmas. Three different Regions of Interest inside TJ-II vacuum vessel have been determined whose thermographic analysis will be applied to the study of beam related processes. The optical conditions required for each application have been used to define the specifications of the IR camera. Optimization of the optical design has been carried out by means of the optical simulation code ZEMAX. The IR window size has been increased to maximize the fraction of the field of view that is free from vignetting. The system has been fully commissioned and is now operative, routinely providing thermographic data of the regions of interest during the last TJ-II experimental campaign. The IR diagnostic is described in detail and its applicability to study beam power deposition on different targets is discussed.
- Open Access
- 2 August 2014
- Published by SPIE-Intl Soc Optical Eng
- Vol. 9143, 91434B-91434B-10
The optical design of a far infrared imaging FTS for SPICA
This paper describes the optical design of the far infrared imaging spectrometer for the JAXA's SPICA mission. The SAFARI instrument, is a cryogenic imaging Fourier transform spectrometer (iFTS), designed to perform backgroundlimited spectroscopic and photometric imaging in the band 34-210 μm. The all-reflective optical system is highly modular and consists of three main modules; input optics module, interferometer module (FTS) and camera bay optics. A special study has been dedicated to the spectroscopic performance of the instrument, in which the spectral response and interference of the instrument have been modeled, as the FTS mechanism scans over the total desired OPD range
- 2 August 2014
- Published by SPIE-Intl Soc Optical Eng
- Vol. 9143, 91434B-91434B-10
Open AccessThe optical design of a far infrared imaging FTS for SPICA
This paper describes the optical design of the far infrared imaging spectrometer for the JAXA's SPICA mission. The SAFARI instrument, is a cryogenic imaging Fourier transform spectrometer (iFTS), designed to perform backgroundlimited spectroscopic and photometric imaging in the band 34-210 μm. The all-reflective optical system is highly modular and consists of three main modules; input optics module, interferometer module (FTS) and camera bay optics. A special study has been dedicated to the spectroscopic performance of the instrument, in which the spectral response and interference of the instrument have been modeled, as the FTS mechanism scans over the total desired OPD range