Masato Tanaka
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Masato Tanaka has a total of 13 co-authors. Here are the top co-authors by number of shared publications:
H Tani
Nippon Steel Corp. 1 T. Naniwa and M. Shibaike are with , M. Tanaka is with , H. Tani is with , K. Shiota is with , N. Hanawa and T. Shiraishi are with , All the members belong to , 9-4, Otemachi-1-Chome, Chiyoda-ku, Tokyo, Japan
1 shared publication- Hideki Shigematsu
Department of Orthopedic Surgery, Nara Medical University, Kashihara, Nara, Japan
1 shared publication K Shiota
Nippon Steel Corp. 1 T. Naniwa and M. Shibaike are with , M. Tanaka is with , H. Tani is with , K. Shiota is with , N. Hanawa and T. Shiraishi are with , All the members belong to , 9-4, Otemachi-1-Chome, Chiyoda-ku, Tokyo, Japan
1 shared publicationM Shibaike
Nippon Steel Corp. 1 T. Naniwa and M. Shibaike are with , M. Tanaka is with , H. Tani is with , K. Shiota is with , N. Hanawa and T. Shiraishi are with , All the members belong to , 9-4, Otemachi-1-Chome, Chiyoda-ku, Tokyo, Japan
1 shared publicationMasahiko Kawaguchi
Nara Medical University
1 shared publicationN Hanawa
Nippon Steel Corp. 1 T. Naniwa and M. Shibaike are with , M. Tanaka is with , H. Tani is with , K. Shiota is with , N. Hanawa and T. Shiraishi are with , All the members belong to , 9-4, Otemachi-1-Chome, Chiyoda-ku, Tokyo, Japan
1 shared publication
Latest Publications
- Open Access
- 8 November 2024
- Published by SAGE Publications in Global Spine Journal
- Vol. 15 (2) , 1473-1478
Does Post-Tetanic Transcranial Stimulation Augment the Wave Amplitudes of Spinal Cord Evoked Potential (Tc-SCEP)?
Study design: Prospective within-subjects study. Objectives: Although motor-evoked potential (MEP) amplitude can reportedly be increased by tetanic stimulation of the peripheral nerves before transcranial electrical stimulation (TES), no reports have described on whether tetanic transcranial stimulation augments the wave amplitudes of spinal cord-evoked potentials (Tc-SCEP). The primary purpose of this study was to investigate whether tetanic stimulation induces waveform amplification of Tc-SCEP. The secondary purpose was to elucidate the mechanism of the amplification effect of tetanic stimulation. Methods: We recruited 20 patients who underwent cervical or thoracic spine surgeries. We compared the compound muscle active potentials (CMAPs) of Tc-MEP and Tc-SCEP before and after tetanic stimulation of the median or tibial nerve. Results: Although the CMAP wave amplitudes of the abductor pollicis brevis (APB) and abductor hallucis (AH) showed significant enlargement on Tc-MEP following tetanic stimulation of the median and tibial nerves, an augmentation effect regarding Tc-SCEP (203 μV [without tetanic stimulation], 212 μV [tetanic stimulation of the median nerve], and 208 μV [tetanic stimulation of tibial nerve]) could not be demonstrated. Conclusion: Although MEP amplitudes can be enlarged by tetanic stimulation of the peripheral nerves, the amplification mechanism may not involve the lateral corticospinal tract from the brain stem to the anterior horn.
- 8 November 2024
- Published by SAGE Publications in Global Spine Journal
- Vol. 15 (2) , 1473-1478
Open AccessDoes Post-Tetanic Transcranial Stimulation Augment the Wave Amplitudes of Spinal Cord Evoked Potential (Tc-SCEP)?
Study design: Prospective within-subjects study. Objectives: Although motor-evoked potential (MEP) amplitude can reportedly be increased by tetanic stimulation of the peripheral nerves before transcranial electrical stimulation (TES), no reports have described on whether tetanic transcranial stimulation augments the wave amplitudes of spinal cord-evoked potentials (Tc-SCEP). The primary purpose of this study was to investigate whether tetanic stimulation induces waveform amplification of Tc-SCEP. The secondary purpose was to elucidate the mechanism of the amplification effect of tetanic stimulation. Methods: We recruited 20 patients who underwent cervical or thoracic spine surgeries. We compared the compound muscle active potentials (CMAPs) of Tc-MEP and Tc-SCEP before and after tetanic stimulation of the median or tibial nerve. Results: Although the CMAP wave amplitudes of the abductor pollicis brevis (APB) and abductor hallucis (AH) showed significant enlargement on Tc-MEP following tetanic stimulation of the median and tibial nerves, an augmentation effect regarding Tc-SCEP (203 μV [without tetanic stimulation], 212 μV [tetanic stimulation of the median nerve], and 208 μV [tetanic stimulation of tibial nerve]) could not be demonstrated. Conclusion: Although MEP amplitudes can be enlarged by tetanic stimulation of the peripheral nerves, the amplification mechanism may not involve the lateral corticospinal tract from the brain stem to the anterior horn.
- 1 January 1990
- Published by ASTM International
- p. 67-80
Effects of the Striking Edge Radius on the Charpy Impact Test
Effects of the striking edge radius of the Charpy impact test on the absorbed energy and the abrasion of the striker were investigated. The absorbed energy of the 8mmR was higher than that of the 2mmR when the absorbed energy was above 200N-m. The cause of this difference is that the bending deformation of the test specimen and the friction between the anvil and the test specimen are large in case of the 8mmR. The abrasion of the 8mmR striker was extremely large and it is too difficult to maintain the radius dimension according to ASTM E 23.
- 1 January 1990
- Published by ASTM International
- p. 67-80
Effects of the Striking Edge Radius on the Charpy Impact Test
Effects of the striking edge radius of the Charpy impact test on the absorbed energy and the abrasion of the striker were investigated. The absorbed energy of the 8mmR was higher than that of the 2mmR when the absorbed energy was above 200N-m. The cause of this difference is that the bending deformation of the test specimen and the friction between the anvil and the test specimen are large in case of the 8mmR. The abrasion of the 8mmR striker was extremely large and it is too difficult to maintain the radius dimension according to ASTM E 23.