ÁÁÁlvaro De la Cruz Álamo

Álvaro De la Cruz Álamo

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Álvaro De la Cruz Álamo has a total of 11 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Transfer learning applied to tidal current predictions with limited data availability

    by Álvaro C. Álamo, Miguel Bruno, Juan A. Morales, Reyes Sánchez-Herrera

  • Open Access

    Single-Phase Voltage Sag Generator Based on Three Random-Fire Solid-State Relays with Programmable Angle of Inception for IEC 61000-4-11 Testing

    by Álvaro C. Álamo, Hugo Rodríguez, Jesús Clavijo Camacho, María Reyes Sánchez Herrera

    Voltage sags are the most frequent power quality disturbance on low-voltage networks, and equipment immunity is verified against IEC 61000-4-11:2020. Laboratory-grade generators are expensive, and low-cost alternatives based on zero-crossing solid-state relays cannot control the angle of inception, a parameter that changes the drop-out time of an electromagnetic contactor by a factor of 6.5. This paper presents a single-phase sag generator built from three random-fire solid-state relays driven by an Arduino MEGA 2560 R3. Two relays commutate between the mains and a variable autotransformer; a third, in series with a transition resistor, bridges the switchover, removing the dead half-cycle of two-relay zero-crossing topologies. Over 576 measurements, the generator reproduces the angle of inception across 0–175° modulo 180°, and, therefore, equivalent to the full cycle for a polarity-insensitive load, with an expanded uncertainty of ±1.33° (k = 2), and the dead interval falls from 17.5 ms to 0.009 ms. Four of the six level–duration conditions prescribed for a class 3 environment are reproduced within tolerance; the two sub-cycle interruptions are not, the shortest sag being three half-cycles. Three limitations are quantified: the recovery instant is not programmable, being fixed by the current zero of the outgoing branch; it shifts by the load impedance angle under reactive loads; and non-linear loads were not tested. A design inequality for the transition resistor bounds the deliverable load power, and the firmware is open source.

  • Open Access

    From Nominal Flexibility to Firm Reserve: A Readiness Assessment of Thermostatically Controlled Loads for Primary Frequency Response

    by Juan P. Torreglosa, Reyes Sánchez-Herrera, Jesús Clavijo-Camacho, José Antonio Hernández-Torres, Álvaro C. Álamo

    Thermostatically controlled loads (TCLs) can respond rapidly to frequency disturbances, but fast modulation alone does not establish firm primary-frequency reserve. This study develops a readiness framework that links evidence synthesis, probabilistic reserve sizing, post-event recovery and feeder-level compatibility. A focused review of 74 journal studies informed a two-stage simulation framework. Stage A combined deterministic stress testing, 300-realization Monte Carlo sizing and an independent capacity-hold verification, while Stage B embedded this independently simulated profile in an 8500-node benchmark distribution feeder. The realistic aggregation remained frequency-responsive, but operational constraints produced substantial nominal-to-firm derating. For the modeled upward-reserve case, under the assumed population distributions and operating conditions, an empirical declaration of 0.885 MW achieved approximately 95% joint compliance, while only 56.35% of event-state nominal upward flexibility was firm in the independent verification. Recovery remained distinct from delivery readiness, and feeder analysis showed that an aggregate-compliant profile could still create local voltage and loading violations. The results show that credible TCL reserve requires reliability-conditioned derating, explicit recovery assessment and feeder-specific qualification rather than reliance on nominal flexibility or response speed alone.

  • Open Access

    Gestión inteligente de turbinas mareales mediante lógica difusa

    by Álvaro De la Cruz Álamo, Gabriel Gómez Ruíz, María Reyes Sánchez Herrera, Juan Pérez Torreglosa

    Este artículo presenta la simulación de un Sistema de Gestión de Energía (EMS) basado en lógica difusa, aplicado a una instalación de generación eléctrica con corrientes mareales. La instalación consta de una turbina generadora, un convertidor para operar en el punto máximo de potencia, un banco de baterías para almacenamiento y un inversor para inyección a la red. El EMS funciona como un control inteligente que evalúa la energía disponible en el recurso marino, el estado de carga (SOC) de las baterías y el coste instantáneo de electricidad, para determinar la potencia óptima a inyectar según la estrategia implementada (como priorizar rentabilidad o prolongar la vida útil de las baterías). La lógica difusa permite manejar la incertidumbre y variabilidad ambiental, logrando una operación más flexible y eficiente. Los resultados muestran que el EMS mejora la estabilidad operativa, optimiza el uso del recurso energético y favorece una gestión más rentable y sostenible.

  • Open Access

    Advanced Distribution System Optimization: Utilizing Flexible Power Buses and Network Reconfiguration

    by Jesus Clavijo-Camacho, Francisco J. Ruiz-Rodríguez, Reyes Sánchez-Herrera, Alvaro C. Alamo

    The increasing integration of distributed generation (DG) and the rise of microgrids have reshaped the operation of distribution systems, introducing both challenges and opportunities for optimization. This study presents a methodology that combines network reconfiguration with the integration of buses with flexible power in order to improve the efficiency and cost-effectiveness of distribution networks. Flexible buses, which aggregate multiple microgrids or controllable distributed resources, function as control points that can dynamically adjust active and reactive power within predefined limits. This capability allows for more precise management of power flows, enabling the system to respond to fluctuations in generation and demand. The proposed optimization framework aims to minimize the total operational costs, including power losses and the use of flexible power, while adhering to system constraints. The methodology is evaluated through case studies on two distribution systems: the Kumamoto and IEEE-33 systems. The results indicate a 43.9% reduction in power losses for the Kumamoto system and a 66.6% reduction for the IEEE-33 system, along with notable cost savings in both cases. These outcomes demonstrate the potential benefits of incorporating flexible power buses in modern radial distribution networks, showing their role in adapting to various operational scenarios and supporting the integration of distributed generation and microgrids.