LKLynn Kandakji

Lynn Kandakji

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Lynn Kandakji has a total of 21 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Automated Triage for New Keratoconus Referrals Using Multimodal Deep Learning

    by Shafi Balal, Lynn Kandakji, Marcello Leucci, Pearse A. Keane, Daniel Gore, Nikolas Pontikos, Bruce D. Allan


  • Open Access

    An Open-Source Deep Learning Framework for Automated Corneal Segmentation in Anterior Segment Optical Coherence Tomography With Cross-Device External Validation

    by Lynn Kandakji, Siyin Liu, Shafi Balal, Ismail Moghul, Bruce Allan, Stephen Tuft, Daniel Gore, Nikolas Pontikos

    Purpose: To develop a deep learning model—Cornea nnU-Net Extractor (CUNEX)—for full-thickness corneal segmentation of anterior segment optical coherence tomography (AS-OCT) images and evaluate its utility in artificial intelligence research. Methods: CUNEX was developed and evaluated using our Moorfields AS-OCT dataset of 194,599 scans from 37,499 patients, from which 100 normal, 100 keratoconus, and 100 Fuchs endothelial corneal dystrophy eyes were selected for model training. External validation was performed without fine-tuning using AS-OCT images acquired on 4 different OCT devices: Casia SS-1000, Anterion, Visante, and a ultrahigh-resolution custom build. CUNEX was benchmarked against 2 established models, CorneaNet and ScLNet. We then evaluated whether CUNEX-based segmentation influenced downstream deep learning classification of age, sex, and disease staging. Results: On the internal MS-39 validation set, CUNEX achieved Dice similarity coefficient (DSC) and intersection over union (IoU) scores of 94% to 95% and 88% to 91% across healthy, keratoconus, and Fuchs endothelial corneal dystrophy eyes, comparable to ScLNet (within 3%) and superior to CorneaNet (8%–35% lower). On external datasets, CUNEX was the only model to produce anatomically meaningful segmentations across devices (DSC and IoU >70%), whereas ScLNet and CorneaNet showed substantial performance degradation (DSC and IoU <20%). Segmentation minimally affected classification accuracy except for sex prediction, where accuracy dropped from 81% to 68%, suggesting sex-related features may lie outside the cornea. Conclusions: CUNEX delivers the first open-source AS-OCT corneal segmentation model evaluated across multiple independent OCT platforms. It offers a reproducible foundation for integrating segmentation into clinical and artificial intelligence research workflows. The code and pretrained weights are available at https://github.com/lkandakji/CUNEX.


  • Open Access

    Establishing the ground truth for keratoconus progression: combining repeated measures and adapting precision limits to disease severity in corneal tomography

    by Shafi Balal, Yijun Cai, Lynn Kandakji, Siyin Liu, Pádraig J. Mullholand, Marcello Leucci, Nikolas Pontikos, Daniel Gore, Bruce Allan

    Purpose: To analyze measurement precision using a contemporary tomography device (MS-39) in a large sample of patients with keratoconus. Setting: Moorfields Eye Hospital, London, United Kingdom. Design: Prospective and retrospective analyses of clinical data. Methods: For a range of key corneal tomographic indices, repeatability and reproducibility were compared in a prospective series of 1248 scans (n = 208 eyes) with 2 observers each acquiring 3 scans per eye. Measurement repeatability for single measures vs the mean of 3 consecutive measures was then compared using the same dataset. 95% repeatability coefficients were mapped at each unit interval through the measurement range in a retrospective analysis of 13 734 scans (n = 4578 eyes) to adapt progression thresholds to disease severity. Finally, keratoconus classification using alternate progression definitions was compared at 1 and 2-year time points. Results: For all corneal tomographic indices examined, no significant differences were found between MS-39 measurement repeatability and reproducibility (P > .05), repeatability was (average) 44% improved using the mean of 3 consecutive measures, and measurement repeatability deteriorated as keratoconus advanced. Progression was classified incorrectly in over 50% of cases at both time points where adaptive thresholds and repeated measures were not used. Conclusions: MS-39 measurement precision was not significantly influenced by the operator. Consecutive repeated measures and adaptive thresholds for observed change in key tomographic parameters based on device-specific precision limits tailored to disease severity are necessary for accurate classification of progression.


  • Open Access

    An Open-Source Generalizable Deep Learning Framework for Automated Corneal Segmentation in Anterior Segment Optical Coherence Tomography Imaging

    by Lynn Kandakji, Siyin Liu, Shafi Balal, Ismail Moghul, Bruce Allan, Stephen Tuft, Daniel Gore, Nikolas Pontikos

    Purpose: To develop a deep learning model – Cornea nnU-Net Extractor (CUNEX) – for full-thickness corneal segmentation of anterior segment optical coherence tomography (AS-OCT) images and evaluate its utility in artificial intelligence (AI) research. Methods: We trained and evaluated CUNEX using nnU-Net on 600 AS-OCT images (CSO MS-39) from 300 patients: 100 normal, 100 keratoconus (KC), and 100 Fuchs endothelial corneal dystrophy (FECD) eyes. To assess generalizability, we externally validated CUNEX on 1,168 AS-OCT images from an infectious keratitis dataset acquired from a different device (Casia SS-1000). We benchmarked CUNEX against two recent models, CorneaNet and ScLNet. We then applied CUNEX to our dataset of 194,599 scans from 37,499 patients as preprocessing for a classification model evaluating whether segmentation improves AI prediction, including age, sex, and disease staging (KC and FECD). Results: CUNEX achieved Dice similarity coefficient (DSC) and intersection over union (IoU) scores ranging from 94–95% and 90–99%, respectively, across healthy, KC, and FECD eyes. This was similar to ScLNet (within 3%) but better than CorneaNet (8–35% lower). On external validation, CUNEX maintained high performance (DSC 83%; IoU 71%) while ScLNet (DSC 14%; IoU 8%) and CorneaNet (DSC 16%; IoU 9%) failed to generalize. Unexpectedly, segmentation minimally impacted classification accuracy except for sex prediction, where accuracy dropped from 81 to 68%, suggesting sex-related features may lie outside the cornea. Conclusion: CUNEX delivers the first open-source generalizable corneal segmentation model using the latest framework, supporting its use in clinical analysis and AI workflows across diseases and imaging platforms. It is available at https://github.com/lkandakji/CUNEX .


  • Open Access

    Current applications of artificial intelligence for Fuchs endothelial corneal dystrophy: a systematic review

    by Siyin Liu, Lynn Kandakji, Aleksander Stupnicki, Dayyanah Sumodhee, Marcello Leucci, Scott Hau, Shafi Balal, Arthur Okonkwo, Ismail Moghul, Bruce Allan, et al.

    Purpose: Fuchs Endothelial Corneal Dystrophy (FECD) is a common, age-related cause of visual impairment. This systematic review synthesizes evidence from the literature on Artificial Intelligence (AI) models developed for the diagnosis and management of FECD. Methods: We conducted a systematic literature search in MEDLINE, PubMed, Web of Science, and Scopus from January 1, 2000, to June 31, 2024. Full-text studies utilizing AI for various clinical contexts of FECD management were included. Data extraction covered model development, predicted outcomes, validation, and model performance metrics. We graded included studies using the Quality Assessment of Diagnostic Accuracies Studies 2 tool. This review adheres to the PRISMA (Preferred Reporting Items for Systematic Reviews and Meta-Analyses) recommendations. Results: Nineteen studies were analyzed. Primary AI algorithms applied in FECD diagnosis and management included neural network architectures specialized for computer vision, utilized on confocal or specular microscopy images, or anterior segment optical coherence tomography images. AI was employed in diverse clinical contexts, such as assessing corneal endothelium and edema, and predicting post-corneal transplantation graft detachment and survival. Despite many studies reporting promising model performance, a notable limitation was that only 3 studies performed external validation. Bias introduced by patient selection processes and experimental designs was evident in the included studies. Conclusions: Despite the potential of AI algorithms to enhance FECD diagnosis and prognostication, further work is required to evaluate their real-world applicability and clinical utility. Translational Relevance: This review offers critical insights for researchers, clinicians, and policymakers, aiding their understanding of existing AI research in FECD management and guiding future health service strategies.