Ansel R. Moll
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Ansel R. Moll has a total of 16 co-authors. Here are the top co-authors by number of shared publications:
- Jennifer A. Field
Oregon State University
3 shared publications - Mitchell L. Kim-Fu
Department of Environmental and Molecular Toxicology, Oregon State University , Corvallis, OR
3 shared publications Esteban E. Hernandez
Department of Chemistry, Oregon State University, 153 Gilbert, Corvallis, Oregon 97331, United States
2 shared publications- Boris Droz
Institut Terre et Environnement de Strasbourg (ITES), University of Strasbourg/ENGEES, CNRS UMR 7063, France
1 shared publication Chris G. Heron
Jacobs Solutions, 1100 NE Circle Blvd., Corvallis, Oregon 97330, United States
1 shared publication- Gerrad D. Jones
Biological & Ecological Engineering, Oregon State University, 116 SW 26th St. Corvallis, Oregon 97331, United States
1 shared publication
Latest Publications
- 3 June 2026
- Published by American Chemical Society (ACS) in Environmental Science & Technology
- Vol. 60 (23) , 16818-16829
Per- and Polyfluoroalkyl Substances and Total Organic Fluorine Ratios from Field-Collected Light Nonaqueous Phase Liquids and Groundwater
Per- and polyfluoroalkyl substances (PFAS) and light nonaqueous phase liquid (LNAPL) co-occur in the subsurface at military installations. Concentrations of PFAS in 13 paired LNAPL and groundwater samples collected from groundwater wells were used to compute LNAPL:groundwater ratios (γLNAPL-GW). Individual target PFAS were determined by liquid chromatography-quadrupole time-of-flight mass spectrometry (LC-QTOF) while total organic fluorine and fluoride were determined by 19F nuclear magnetic resonance spectroscopy (NMR). The percent aromatic content of LNAPL was determined using 13C NMR. The PFAS concentrations in LNAPL ranged from 80 ng/L to >5,000,000 ng/L. The summed molar concentration of individual PFAS accounted for up to 26.7% of total organic fluorine. Individual PFAS γLNAPL-GW values ranged from LNAPL-GW for total organic fluorine ranged from 0.003 to 18.3. For a given LNAPL-groundwater sample pair, there was a headgroup and fluorinated chain length effect on γLNAPL-GW. Visualization of γLNAPL-GW across samples indicated that both PFAS structure and LNAPL and groundwater characteristics strongly influenced partitioning. Linear mixed-effects modeling indicated that environmental parameters accounted for 36.5% of the variance in γLNAPL-GW, increasing to 72.0% when PFAS class and chain length were included. Strong multicollinearity among variables limits the ability to identify singular dominant factors; thus, controlled laboratory studies are needed.
- 3 June 2026
- Published by American Chemical Society (ACS) in Environmental Science & Technology
- Vol. 60 (23) , 16818-16829
Per- and Polyfluoroalkyl Substances and Total Organic Fluorine Ratios from Field-Collected Light Nonaqueous Phase Liquids and Groundwater
Per- and polyfluoroalkyl substances (PFAS) and light nonaqueous phase liquid (LNAPL) co-occur in the subsurface at military installations. Concentrations of PFAS in 13 paired LNAPL and groundwater samples collected from groundwater wells were used to compute LNAPL:groundwater ratios (γLNAPL-GW). Individual target PFAS were determined by liquid chromatography-quadrupole time-of-flight mass spectrometry (LC-QTOF) while total organic fluorine and fluoride were determined by 19F nuclear magnetic resonance spectroscopy (NMR). The percent aromatic content of LNAPL was determined using 13C NMR. The PFAS concentrations in LNAPL ranged from 80 ng/L to >5,000,000 ng/L. The summed molar concentration of individual PFAS accounted for up to 26.7% of total organic fluorine. Individual PFAS γLNAPL-GW values ranged from LNAPL-GW for total organic fluorine ranged from 0.003 to 18.3. For a given LNAPL-groundwater sample pair, there was a headgroup and fluorinated chain length effect on γLNAPL-GW. Visualization of γLNAPL-GW across samples indicated that both PFAS structure and LNAPL and groundwater characteristics strongly influenced partitioning. Linear mixed-effects modeling indicated that environmental parameters accounted for 36.5% of the variance in γLNAPL-GW, increasing to 72.0% when PFAS class and chain length were included. Strong multicollinearity among variables limits the ability to identify singular dominant factors; thus, controlled laboratory studies are needed.
- Open Access
- 19 November 2024
- Published by American Chemical Society (ACS) in Environmental Science & Technology
- Vol. 58 (48) , 21295-21304
Release of Volatile Per- and Polyfluoroalkyl Substances from Plant Fiber-Based Food Packaging and Municipal Solid Waste to Gas under Simulated Landfill Conditions
Per- and polyfluoroalkyl substances (PFAS) have been detected in plant fiber-based food packaging and most such packaging is disposed in landfills. The objective of this research was to evaluate the release of volatile PFAS to the gas-phase from PFAS-containing, single-use food packaging materials and from municipal solid waste (MSW) during anaerobic decomposition under simulated landfill conditions. After screening 46 materials for total F and 6:2 fluorotelomer alcohol (FTOH), packaging materials were classified as high or low F. High F materials included microwavable popcorn bags, natural plates, compostable bowls, biodegradable boxes, bagasse containers and eco-friendly plates, while the low F materials tested were paper plates, eco-friendly food trays and poly coated freezer paper. Summed PFAS release from the high F materials was 62-800 ng PFAS/g sample and 6:2 FTOH comprised 96.8-99.9% of the summed PFAS. The low F materials and MSW released 0.1-0.4 ng summed PFAS/g sample and 7:2-secondary (s) FTOH was the dominant volatile PFAS. PFAS were generally released early in the 123-285-day decomposition cycle, suggesting that some PFAS will be released prior to the installation of landfill gas collection systems. Nonetheless, PFAS have been reported in collected landfill gas, indicating that release occurs over many years.
- 19 November 2024
- Published by American Chemical Society (ACS) in Environmental Science & Technology
- Vol. 58 (48) , 21295-21304
Open AccessRelease of Volatile Per- and Polyfluoroalkyl Substances from Plant Fiber-Based Food Packaging and Municipal Solid Waste to Gas under Simulated Landfill Conditions
Per- and polyfluoroalkyl substances (PFAS) have been detected in plant fiber-based food packaging and most such packaging is disposed in landfills. The objective of this research was to evaluate the release of volatile PFAS to the gas-phase from PFAS-containing, single-use food packaging materials and from municipal solid waste (MSW) during anaerobic decomposition under simulated landfill conditions. After screening 46 materials for total F and 6:2 fluorotelomer alcohol (FTOH), packaging materials were classified as high or low F. High F materials included microwavable popcorn bags, natural plates, compostable bowls, biodegradable boxes, bagasse containers and eco-friendly plates, while the low F materials tested were paper plates, eco-friendly food trays and poly coated freezer paper. Summed PFAS release from the high F materials was 62-800 ng PFAS/g sample and 6:2 FTOH comprised 96.8-99.9% of the summed PFAS. The low F materials and MSW released 0.1-0.4 ng summed PFAS/g sample and 7:2-secondary (s) FTOH was the dominant volatile PFAS. PFAS were generally released early in the 123-285-day decomposition cycle, suggesting that some PFAS will be released prior to the installation of landfill gas collection systems. Nonetheless, PFAS have been reported in collected landfill gas, indicating that release occurs over many years.
- 18 November 2024
- Published by Royal Society of Chemistry (RSC) in Environmental Science: Processes & Impacts
- Vol. 26 (12) , 2158-2165
Fluorinated aromatic PBCTF and 6:2 diPAP in bridge and traffic paints
Per- and polyfluoroalkyl substances (PFAS) are reported in residential and commercial paints, but there are no data for paints used in the transportation sector. From 2023 to 2024, 16 traffic paints and 10 bridge paints were collected from Pacific Northwest regional transportation facilities or purchased and analyzed for total fluorine by 19F-nuclear magnetic resonance (NMR) spectroscopy, volatile PFAS by gas chromatography-mass spectrometry (GC-MS), and ionic target and suspect PFAS by liquid chromatography-quadrupole time-of-flight mass spectrometry. The only target PFAS identified was 6:2 fluorotelomer phosphate diester (diPAP) which ranged in concentrations from 0.065 to 13 μg g−1. While 6:2 diPAP is not regulated in paints, it can undergo environmental transformation to act as a source of perfluoroalkyl carboxylic acids. A combination of 19F-NMR and GC-MS was used to quantify and identify the fluorinated aromatic PFAS, parachlorobenzotrifluoride (PCBTF), at concentrations from 440 to 16 000 μg g−1 in bridge paints, thus PCBTF may contribute to work exposure and levels in urban air. Additionally, evolved gas analysis with mass spectrometry and pyrolysis-GC-MS established that the insoluble fraction of paints is not comprised of fluoropolymers. Based on the amount of paint required per kilometer, we estimate up to 0.20–2.30 g 6:2 diPAP per kilometer depending on marking type. Therefore, traffic paint may be a potential source of the PFAS detected in urban runoff.
- 18 November 2024
- Published by Royal Society of Chemistry (RSC) in Environmental Science: Processes & Impacts
- Vol. 26 (12) , 2158-2165
Fluorinated aromatic PBCTF and 6:2 diPAP in bridge and traffic paints
Per- and polyfluoroalkyl substances (PFAS) are reported in residential and commercial paints, but there are no data for paints used in the transportation sector. From 2023 to 2024, 16 traffic paints and 10 bridge paints were collected from Pacific Northwest regional transportation facilities or purchased and analyzed for total fluorine by 19F-nuclear magnetic resonance (NMR) spectroscopy, volatile PFAS by gas chromatography-mass spectrometry (GC-MS), and ionic target and suspect PFAS by liquid chromatography-quadrupole time-of-flight mass spectrometry. The only target PFAS identified was 6:2 fluorotelomer phosphate diester (diPAP) which ranged in concentrations from 0.065 to 13 μg g−1. While 6:2 diPAP is not regulated in paints, it can undergo environmental transformation to act as a source of perfluoroalkyl carboxylic acids. A combination of 19F-NMR and GC-MS was used to quantify and identify the fluorinated aromatic PFAS, parachlorobenzotrifluoride (PCBTF), at concentrations from 440 to 16 000 μg g−1 in bridge paints, thus PCBTF may contribute to work exposure and levels in urban air. Additionally, evolved gas analysis with mass spectrometry and pyrolysis-GC-MS established that the insoluble fraction of paints is not comprised of fluoropolymers. Based on the amount of paint required per kilometer, we estimate up to 0.20–2.30 g 6:2 diPAP per kilometer depending on marking type. Therefore, traffic paint may be a potential source of the PFAS detected in urban runoff.